| 7395.1 |
FW-120 |
Min 24 ga., max 12" wide, 1.5" deep concealed fastened wall panels |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +120/-103.5 Other: Allowable load of +120/-103.5 psf for 22 ga. FW-120 at support spacing of 24" o.c. |
Installation Instructions FL7395_R8_II_EvaluationReportC2685_1.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL7395_R8_AE_EvaluationReportC2685_1.pdf Created by Independent Third Party: Yes |
|
|
| 7395.2 |
PBA Panel |
Min. 26 ga., 36" wide, through fastened panel over open supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See evaluation report for limitations and load tables. |
Installation Instructions FL7395_R8_II_EvaluationReportC2685_2.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL7395_R8_AE_EvaluationReportC2685_2.pdf Created by Independent Third Party: Yes |
|
|
| 7395.3 |
PBM Panel |
Min. 26 ga., 36" wide, through fastened panel over open supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-118.9 Other: Outward load of 118.9 psf at support spacing of 24" o.c. |
Installation Instructions FL7395_R8_II_EvaluationReportC2685_3.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL7395_R8_AE_EvaluationReportC2685_3.pdf Created by Independent Third Party: Yes |
|
|
| 7395.4 |
PBR Panel |
Min. 26 ga., 36" wide, through fastened panel over open supports
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-193.8 Other: Outward load of 193.8 psf at support spacing of 24" o.c. for Fastener Pattern 2. |
Installation Instructions FL7395_R8_II_EvaluationReportC2685_4.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL7395_R8_AE_EvaluationReportC2685_4.pdf Created by Independent Third Party: Yes |