13872.1 |
CMST12, CMST14, CMSTC16, CS14, CS16, CS18, CS20, CS22 |
Coiled Straps |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13872_R3_II_ER-124.pdf Verified By: IAPMO UES Created by Independent Third Party: Evaluation Reports FL13872_R3_AE_ER-124.pdf |
|
13872.2 |
FCB43.5, FCB45.5, FCB47.5, FCB49.5, FCB411.5 |
Bypass Framing Fixed-Clip Connector
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13872_R3_II_ER-238.pdf Verified By: IAPMO UES Created by Independent Third Party: Evaluation Reports FL13872_R3_AE_ER-238.pdf |
|
13872.3 |
HRS6, HRS8, HRS12, FHA6, FHA9, FHA12, FHA18, FHA24, FHA30, MSTI26, MSTI36, MSTI48, MSTI60, MSTI72, S/MST27, S/MST37, S/MST48 |
Straps 97 mil (12 ga) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: When resisting wind uplift, supplemental connectors may be required to achieve 700# uplift for HVHZ. |
Installation Instructions FL13872_R3_II_ER-124.pdf Verified By: IAPMO UES Created by Independent Third Party: Evaluation Reports FL13872_R3_AE_ER-124.pdf |
|
13872.4 |
HTS16, HTS20, HTS24, HTS28, HTS30, HTS30C |
Heavy Twist Straps |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13872_R3_II_ER-124.pdf Verified By: IAPMO UES Created by Independent Third Party: Evaluation Reports FL13872_R3_AE_ER-124.pdf |
|
13872.5 |
LSFC2.25, LSFC4.25, LSFC6.25, SFC2.25, SFC4.25, SFC6.25 |
Steel Framing Connector |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: When resisting wind uplift, supplemental connectors may be required to achieve 700# uplift for HVHZ. |
Installation Instructions FL13872_R3_II_ER-238.pdf Verified By: IAPMO UES Created by Independent Third Party: Evaluation Reports FL13872_R3_AE_ER-238.pdf |
|
13872.6 |
LSSC4.25, LSSC6.25, SSC2.25, SSC4.25, SSC6.25, MSSC2.25, MSSC4.25, MSSC6.25, MSSC4.25KW, MSSC6.25KW |
Steel Stud Connectors |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: When resisting wind uplift, supplemental connectors may be required to achieve 700# uplift for HVHZ. |
Installation Instructions FL13872_R3_II_ER-238.pdf Verified By: IAPMO UES Created by Independent Third Party: Evaluation Reports FL13872_R3_AE_ER-238.pdf |
|
13872.7 |
LSTA30, LSTA36, LSTI49, LSTI73, MSTA9, MSTA12, MSTA15, MSTA18, MSTA21, MSTA24 |
Straps 43 mil (18 ga) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13872_R3_II_ER-124.pdf Verified By: IAPMO UES Created by Independent Third Party: Evaluation Reports FL13872_R3_AE_ER-124.pdf |
|
13872.8 |
LSTA9, LSTA12, LSTA15, LSTA18, LSTA21, LSTA24, ST292, ST2122, ST2115, ST2215 |
Straps 33 mil (20 ga) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: When resisting wind uplift, supplemental connectors may be required to achieve 700# uplift for HVHZ. |
Installation Instructions FL13872_R3_II_ER-124.pdf Verified By: IAPMO UES Created by Independent Third Party: Evaluation Reports FL13872_R3_AE_ER-124.pdf |
|
13872.9 |
LSUBH3.25, SUBH3.25, MSUBH3.25 |
Bridging Connector
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13872_R3_II_ER-124.pdf Verified By: IAPMO UES Created by Independent Third Party: Evaluation Reports FL13872_R3_AE_ER-124.pdf |
|
13872.10 |
LTP5 |
Lateral Tie Plate |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: This product has not been evaluated for uplift resistance. |
Installation Instructions FL13872_R3_II_ER-124.pdf Verified By: IAPMO UES Created by Independent Third Party: Evaluation Reports FL13872_R3_AE_ER-124.pdf |
|
13872.11 |
LTS12, LTS16, LTS18, LTS20 |
Light Twist Straps |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13872_R3_II_ER-124.pdf Verified By: IAPMO UES Created by Independent Third Party: Evaluation Reports FL13872_R3_AE_ER-124.pdf |
|
13872.12 |
MSTA30, MSTA36, ST6215, ST6224, ST9, ST12, ST18, ST22, MSTC28, MSTC40, MSTC52 |
Straps 54 mil (16 ga) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13872_R3_II_ER-124.pdf Verified By: IAPMO UES Created by Independent Third Party: Evaluation Reports FL13872_R3_AE_ER-124.pdf |
|
13872.13 |
MSTC66, MSTC78, ST6236 |
Straps 68 mil (14 ga) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13872_R3_II_ER-124.pdf Verified By: IAPMO UES Created by Independent Third Party: Evaluation Reports FL13872_R3_AE_ER-124.pdf |
|
13872.14 |
MTS12, MTS16, MTS18, MTS20, MTS30, MTS24C, MTS30C |
Medium Twist Straps |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13872_R3_II_ER-124.pdf Verified By: IAPMO UES Created by Independent Third Party: Evaluation Reports FL13872_R3_AE_ER-124.pdf |
|
13872.15 |
RCKW3, RCKW5.5, RCKW7.5, RCKW3S, RCKW5.5S |
Rigid Knee Wall Connector |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13872_R3_II_ER-238.pdf Verified By: IAPMO UES Created by Independent Third Party: Evaluation Reports FL13872_R3_AE_ER-238.pdf |
|
13872.16 |
S/B1.56, S/B1.81, S/B2.06, S/B2.37, S/B2.56, S/B2.68, S/B3.12, S/B3.56, S/B3.62, S/B4.06, S/B4.12, S/B4.28, S/B4.75, S/B5.50 |
Joist Hangers |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: When resisting wind uplift, supplemental connectors may be required to achieve 700# uplift for HVHZ. |
Installation Instructions FL13872_R3_II_ER-124.pdf Verified By: IAPMO UES Created by Independent Third Party: Evaluation Reports FL13872_R3_AE_ER-124.pdf |
|
13872.17 |
S/BA2.12/8, S/BA2.12/10, S/BA2.12/12, S/BA2.12/14, S/BA4.18/8, S/BA4.18/10, S/BA4.18/12, S/BA4.18/14 |
Joist Hangers |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: When resisting wind uplift, supplemental connectors may be required to achieve 700# uplift for HVHZ. |
Installation Instructions FL13872_R3_II_ER-124.pdf Verified By: IAPMO UES Created by Independent Third Party: Evaluation Reports FL13872_R3_AE_ER-124.pdf |
|
13872.18 |
S/H1A |
Hurricane Tie |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: When resisting wind uplift, supplemental connectors may be required to achieve 700# uplift for HVHZ. |
Installation Instructions FL13872_R3_II_ER-124.pdf Verified By: IAPMO UES Created by Independent Third Party: Evaluation Reports FL13872_R3_AE_ER-124.pdf |
|
13872.19 |
S/HD8S, S/HD8B, S/HD10S, S/HD10B, S/HD15S, S/HD15B |
Holdowns |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13872_R3_II_ER-124.pdf Verified By: IAPMO UES Created by Independent Third Party: Evaluation Reports FL13872_R3_AE_ER-124.pdf |
|
13872.20 |
S/HDU4, S/HDU6, S/HDU9, S/HDU11 |
Holdowns |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13872_R3_II_ER-124.pdf Verified By: IAPMO UES Created by Independent Third Party: Evaluation Reports FL13872_R3_AE_ER-124.pdf |