| 9555.1 | 
5V Panel | 
29 ga., 24" wide, through fastened panel over wood supports | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +N/A/-70.25  Other: Uplift load of 70.25 psf @ support spacing of 24" o.c. | 
Installation Instructions  FL9555_R4_II_EvaluationReportC2172_1.pdf  Verified By: Bala Sockalingam PE 62240  Created by Independent Third Party: Yes Evaluation Reports  FL9555_R4_AE_EvaluationReportC2172_1.pdf  Created by Independent Third Party: Yes | 
										
	
		| 
											 | 
| 9555.2 | 
MasterRib Panel | 
26 ga., 36" wide, through fastened panel over steel supports | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +N/A/-47.2  Other: Uplift load of 47.2 psf @ support spacing of 60" o.c. | 
Installation Instructions  FL9555_R4_II_EvaluationReportC2172_2.pdf  Verified By: Bala Sockalingam PE 62240  Created by Independent Third Party: Yes Evaluation Reports  FL9555_R4_AE_EvaluationReportC2172_2.pdf  Created by Independent Third Party: Yes | 
										
	
		| 
											 | 
| 9555.3 | 
MasterRib Panel | 
29 ga., 36" wide, through fastened panel over steel supports | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +27.1/-37.7  Other: Design load of 27.1 & -37.7 psf at support spacing of 48" o.c. | 
Installation Instructions  FL9555_R4_II_EvaluationReportC2172_3.pdf  Verified By: Bala Sockalingam PE 62240  Created by Independent Third Party: Yes Evaluation Reports  FL9555_R4_AE_EvaluationReportC2172_3.pdf  Created by Independent Third Party: Yes | 
										
	
		| 
											 | 
| 9555.4 | 
MasterRib Panel | 
29 ga., 36" wide, through fastened panel over wood supports | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +27.1/-36.2  Other: Design load of 27.1 & -36.2 psf at support spacing of 48" o.c. | 
Installation Instructions  FL9555_R4_II_EvaluationReportC2172_4.pdf  Verified By: Bala Sockalingam PE 62240  Created by Independent Third Party: Yes Evaluation Reports  FL9555_R4_AE_EvaluationReportC2172_4.pdf  Created by Independent Third Party: Yes | 
										
	
		| 
											 | 
| 9555.5 | 
MasterRib Panel | 
29 ga., 36" wide, through fastened panel over nom. 1" x 4" wood supports | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +N/A/-138.9  Other: Uplift load of 138.9 psf @ support spacing of 24" o.c. | 
Installation Instructions  FL9555_R4_II_EvaluationReportC2172_5.pdf  Verified By: Bala Sockalingam PE 62240  Created by Independent Third Party: Yes Evaluation Reports  FL9555_R4_AE_EvaluationReportC2172_5.pdf  Created by Independent Third Party: Yes | 
										
	
		| 
											 | 
| 9555.6 | 
PBR Panel | 
Min. 26 ga., 36" wide, through fastened roof panel over open steel supports | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +96/-163  Other: Design loads of 96 & -163 psf at support spacing of 20" o.c. | 
Installation Instructions  FL9555_R4_II_EvaluationReportC2172_6.pdf  Verified By: Bala Sockalingam PE 62240  Created by Independent Third Party: Yes Evaluation Reports  FL9555_R4_AE_EvaluationReportC2172_6.pdf  Created by Independent Third Party: Yes |