Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL9555-R3
Application Type Revision
Code Version 2014
Application Status Approved
 
Comments
Archived
 
Product Manufacturer UNION CORRUGATING COMPANY
Address/Phone/Email 701 S. KING ST.
FAYETTEVILLE, NC 28301
(910) 813-2432
rblake@unioncorrugating.com
 
Authorized Signature Randy Blake
rblake@unioncorrugating.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Structural Components
Subcategory Roof Deck
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Bala Sockalingam
Florida License PE-62240
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Yoosef Lavi, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL9555_R3_COI_CertificateIndependence.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E15922001
FM 44701992
UL 5801994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL9555_R3_Equiv_TestEquivalent_C1999_3T7.pdf
FL9555_R3_Equiv_TestEquivalent_C1999_8.pdf
 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 03/23/2015
Date Validated 03/24/2015
Date Pending FBC Approval 03/29/2015
Date Approved 06/23/2015
Date Revised 08/23/2017
 
Summary of Products
FL # Model, Number or Name Description
9555.1 5V Panel 29 ga., 24" wide, through fastened panel over wood supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-70.25
 Other: Uplift load of 70.25 psf @ support spacing of 24" o.c.
Installation Instructions
 FL9555_R3_II_EvaluationReportC1999_3.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL9555_R3_AE_EvaluationReportC1999_3.pdf
 Created by Independent Third Party: Yes
9555.2 MasterRib Panel 26 ga., 36" wide, through fastened panel over steel supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-47.2
 Other: Uplift load of 47.2 psf @ support spacing of 60" o.c.
Installation Instructions
 FL9555_R3_II_EvaluationReportC1999_4.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL9555_R3_AE_EvaluationReportC1999_4.pdf
 FL9555_R3_AE_LSC1999_4.pdf
 Created by Independent Third Party: Yes
9555.3 MasterRib Panel 29 ga., 36" wide, through fastened panel over steel supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +27.1/-37.7
 Other: Design load of 27.1 & -37.7 psf at support spacing of 48" o.c.
Installation Instructions
 FL9555_R3_II_EvaluationReportC1999_5.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL9555_R3_AE_EvaluationReportC1999_5.pdf
 FL9555_R3_AE_LSC1999_5.pdf
 Created by Independent Third Party: Yes
9555.4 MasterRib Panel 29 ga., 36" wide, through fastened panel over wood supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +27.1/-36.2
 Other: Design load of 27.1 & -36.2 psf at support spacing of 48" o.c.
Installation Instructions
 FL9555_R3_II_EvaluationReportC1999_6.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL9555_R3_AE_EvaluationReportC1999_6.pdf
 FL9555_R3_AE_LSC1999_6.pdf
 Created by Independent Third Party: Yes
9555.5 MasterRib Panel 29 ga., 36" wide, through fastened panel over nom. 1" x 4" wood supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-138.9
 Other: Uplift load of 138.9 psf @ support spacing of 24" o.c.
Installation Instructions
 FL9555_R3_II_EvaluationReportC1999_7.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL9555_R3_AE_EvaluationReportC1999_7.pdf
 Created by Independent Third Party: Yes
9555.6 PBR Panel 26 ga., 36" wide, through fastened panel over steel supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-52.5
 Other: Uplift load of 52.5 psf @ support spacing of 60.187” o.c.
Installation Instructions
 FL9555_R3_II_EvaluationReportC1999_8.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL9555_R3_AE_EvaluationReportC1999_8.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex