9555.1 |
5V Panel |
29 ga., 24" wide, through fastened panel over wood supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-70.25 Other: Uplift load of 70.25 psf @ support spacing of 24" o.c. |
Installation Instructions FL9555_R3_II_EvaluationReportC1999_3.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9555_R3_AE_EvaluationReportC1999_3.pdf Created by Independent Third Party: Yes |
|
9555.2 |
MasterRib Panel |
26 ga., 36" wide, through fastened panel over steel supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-47.2 Other: Uplift load of 47.2 psf @ support spacing of 60" o.c. |
Installation Instructions FL9555_R3_II_EvaluationReportC1999_4.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9555_R3_AE_EvaluationReportC1999_4.pdf FL9555_R3_AE_LSC1999_4.pdf Created by Independent Third Party: Yes |
|
9555.3 |
MasterRib Panel |
29 ga., 36" wide, through fastened panel over steel supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +27.1/-37.7 Other: Design load of 27.1 & -37.7 psf at support spacing of 48" o.c. |
Installation Instructions FL9555_R3_II_EvaluationReportC1999_5.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9555_R3_AE_EvaluationReportC1999_5.pdf FL9555_R3_AE_LSC1999_5.pdf Created by Independent Third Party: Yes |
|
9555.4 |
MasterRib Panel |
29 ga., 36" wide, through fastened panel over wood supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +27.1/-36.2 Other: Design load of 27.1 & -36.2 psf at support spacing of 48" o.c. |
Installation Instructions FL9555_R3_II_EvaluationReportC1999_6.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9555_R3_AE_EvaluationReportC1999_6.pdf FL9555_R3_AE_LSC1999_6.pdf Created by Independent Third Party: Yes |
|
9555.5 |
MasterRib Panel |
29 ga., 36" wide, through fastened panel over nom. 1" x 4" wood supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-138.9 Other: Uplift load of 138.9 psf @ support spacing of 24" o.c. |
Installation Instructions FL9555_R3_II_EvaluationReportC1999_7.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9555_R3_AE_EvaluationReportC1999_7.pdf Created by Independent Third Party: Yes |
|
9555.6 |
PBR Panel |
26 ga., 36" wide, through fastened panel over steel supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5 Other: Uplift load of 52.5 psf @ support spacing of 60.187” o.c. |
Installation Instructions FL9555_R3_II_EvaluationReportC1999_8.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9555_R3_AE_EvaluationReportC1999_8.pdf Created by Independent Third Party: Yes |