| 12256.1 |
MPF-G |
Fixed Blades Wall Louver Mechanically Attached to 14 Gauge Steel Supports or 24 Gauge Steel PBR Panels |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Missile Impact Level D.
+/-116 psf Design Pressure when attached to 14 Gauge supports, +/-56.7 psf Design Pressure when attached to 24 Gauge PBR Panels. Refer to evaluation report for conditions and limitations of use. Refer to manufacturer's installation instructions as a supplemental guide.
|
Installation Instructions FL12256_R7_II_EvalReport-MPF-G.pdf Verified By: Lucas A. Turner PE #58201 Created by Independent Third Party: Yes Evaluation Reports FL12256_R7_AE_EvalReport-MPF-G.pdf Created by Independent Third Party: Yes |
|
|
| 12256.2 |
MPO-G |
Center-Pivot Adjustable Blades Wall Louver Mechanically Attached to 14 Gauge Steel Supports or 24 Gauge Steel PBR Panels |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Missile Impact Level D. +/-170 psf Design Pressure when attached to 14 Gauge supports, +/-56.7 psf Design Pressure when attached to 24 Gauge PBR Panels.
Refer to evaluation report for conditions and limitations of use. Refer to manufacturer's installation instructions as a supplemental guide. |
Installation Instructions FL12256_R7_II_EvalReport-MPO-G.pdf Verified By: Lucas A. Turner PE #58201 Created by Independent Third Party: Yes Evaluation Reports FL12256_R7_AE_EvalReport-MPO-G.pdf Created by Independent Third Party: Yes |