Product Approval Menu > Application Detail
 
FL # FL16176-R4
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer EFCO Corporation
Address/Phone/Email 1000 County Road
Monett, MO 65708
(417) 235-3193
ghall@apog.com
 
Authorized Signature Greg Hall
ghall@apog.com
 
Technical Representative Chad Bolin
Address/Phone/Email 1000 County Rd
Monett, MO 65708
(800) 221-4169
cbolin@efcocorp.com
 
Quality Assurance Representative Architectural Testing, Incorporated
Address/Phone/Email 130 Derry Court
York, PA 17402
(717) 764-7700
dgmoyer@archtest.com
 
Category Panel Walls
Subcategory Curtain Walls
 
Compliance Method Test Report
 
Testing Lab Architectural Testing, Inc. (an Intertek company) - York, PA
Construction Consulting Laboratory
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2026
Validated By Scott Wolters, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL16176_R4_COI_ATI COI.pdf
FL16176_R4_COI_CCLI Independence Letter.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA 5012015
ASTM E2832019
ASTM E3302021
ASTM E3312016
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL16176_R4_Equiv_FL16176 Equivalency.pdf
 
 
 
 
Product Approval Method Method 1 Option B
 
Date Submitted 10/12/2023
Date Validated 10/23/2023
Date Pending FBC Approval 11/02/2023
Date Approved 12/13/2023
 
Summary of Products
FL # Model, Number or Name Description
16176.1 5600 2.25" x 7" OG/IG Curtainwall
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +80/-80
 Other: Glazing includes 1" and 1/4" exterior and interior glazed lites. Note supplemental test exterior glazed 1" glazing using Duracast pressure plate.
Installation Instructions
 FL16176_R4_II_5600 OutsideInside Glazed AS Tested.pdf
 Verified By: Construction Consulting Laboratory
Test Reports
 FL16176_R4_TR_5600 Outside inside Glazed.pdf
 FL16176_R4_TR_5600-Duracast.pdf
16176.2 5600 2.25" x 7" SSG Curtainwall
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +70/-70
 Other: Glazing include 1" and 1/4" 2 and 4 sided structural glazed lites.
Installation Instructions
 FL16176_R4_II_5600 SSG As Tested.pdf
 Verified By: Construction Consulting Laboratory
Test Reports
 FL16176_R4_TR_5600 SSG.pdf
 
Back   Next
 