Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL16179-R6
Application Type Revision
Code Version 2026
Application Status Applied For
 
Comments
Archived
 
Product Manufacturer Majors Metal Roofing & Custom Sheet Metal, Inc.
Address/Phone/Email 406 NW 54th Street
Miami, FL 33127
(305) 757-9503
marvin@majorsmetal.com
 
Authorized Signature Marvin Carias
marvin@majorsmetal.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Bala Sockalingam
Florida License PE-62240
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 03/30/2033
Validated By Yoosef Lavi, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL16179_R6_COI_CertificateIndependence.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
TAS 1252003
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 10/15/2026
Date Validated
 
Summary of Products
FL # Model, Number or Name Description
16179.1 1.5" Mechanically Seamed Panel 12", 16" or 20" wide, 24 ga. steel, 0.032" thick aluminum or 16 oz copper standing seam roof panel over min. 19/32" thick plywood deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-136.8
 Other: Maximum uplift load of 136.8 psf @ clip spacing of 6" o.c. for 12" & 16" wide 16 oz copper panels with 180 degree seam.
Installation Instructions
 FL16179_R6_II_EvaluationReportC3084_1.pdf
 Verified By: Bala Sockalingam 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16179_R6_AE_EvaluationReportC3084_1.pdf
 Created by Independent Third Party: Yes
16179.2 5V-Crimp Min. 26 ga., 24" wide through fastened roof panel over min. 19/32” thick plywood deck with fasteners through panel rib.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-159.3
 Other: Uplift load of 109.3 psf @ fastener spacing of 12" o.c. and 159.3 psf @ fastener spacing of 6" o.c.
Installation Instructions
 FL16179_R6_II_EvaluationReportC3084_2.pdf
 Verified By: Bala Sockalingam 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16179_R6_AE_EvaluationReportC3084_2.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts: