| 16179.1 |
1.5" Mechanically Seamed Panel |
12", 16" or 20" wide, 24 ga. steel, 0.032" thick aluminum or 16 oz copper standing seam roof panel over min. 19/32" thick plywood deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-136.8 Other: Maximum uplift load of 136.8 psf @ clip spacing of 6" o.c. for 12" & 16" wide 16 oz copper panels with 180 degree seam. |
Installation Instructions FL16179_R6_II_EvaluationReportC3084_1.pdf Verified By: Bala Sockalingam 62240 Created by Independent Third Party: Yes Evaluation Reports FL16179_R6_AE_EvaluationReportC3084_1.pdf Created by Independent Third Party: Yes |
|
|
| 16179.2 |
5V-Crimp |
Min. 26 ga., 24" wide through fastened roof panel over min. 19/32” thick plywood deck with fasteners through panel rib. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-159.3 Other: Uplift load of 109.3 psf @ fastener spacing of 12" o.c. and 159.3 psf @ fastener spacing of 6" o.c. |
Installation Instructions FL16179_R6_II_EvaluationReportC3084_2.pdf Verified By: Bala Sockalingam 62240 Created by Independent Third Party: Yes Evaluation Reports FL16179_R6_AE_EvaluationReportC3084_2.pdf Created by Independent Third Party: Yes |