| 19316.1 |
ERC WV Valves |
Pressure equalization vent for use in low-slope roof assemblies. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-150 Other: 1.) UL TGIK Certification is limited to wind uplift resistance per UL1897. 2.) UL TGIK Certification listings reflect ultimate performance. The 2:1 margin of safety required under FBC 1504.9 shall be applied to establish allowable design pressure. 3.) The Design Pressure noted above pertains to one system, and reflects ultimate pressure (300 psf) divided by 2. Refer to UL TGIK.R38388 certification listings for all assemblies and associated ultimate test pressures. |
Certification Agency Certificate FL19316_R6_C_CAC_2024_05_30_ERC UL TGIK.R38388.pdf Quality Assurance Contract Expiration Date 06/29/2026 Installation Instructions FL19316_R6_II_2024_05_30_ERC UL TGIK.R38388.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |