Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL19330-R4
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer EFCO Corporation
Address/Phone/Email 1000 County Road
Monett, MO 65708
(417) 235-3193
ghall@apog.com
 
Authorized Signature Greg Hall
ghall@apog.com
 
Technical Representative Chad Bolin
Address/Phone/Email 1000 County Rd
Monett, MO 65708
(800) 221-4169
cbolin@efcocorp.com
 
Quality Assurance Representative Josh Coberley
Address/Phone/Email 1000 County Rd
Monett, MO 65708
(417) 235-3193
jcoberley@efcocorp.com
 
Category Windows
Subcategory Fixed
 
Compliance Method Test Report
 
Testing Lab Architectural Testing, Inc. (an Intertek company) - York, PA
Construction Consulting Laboratory
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2026
Validated By Scott Wolters, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL19330_R4_COI_ATI COI.pdf
FL19330_R4_COI_CCLI Independence Letter.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E 18862019
ASTM E 19962020
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL19330_R4_Equiv_FL19330 Equivalency.pdf
 
 
 
 
Product Approval Method Method 1 Option B
 
Date Submitted 10/12/2023
Date Validated 10/19/2023
Date Pending FBC Approval 11/01/2023
Date Approved 12/13/2023
 
Summary of Products
FL # Model, Number or Name Description
19330.1 5FXT Fixed Window 53.75" wide x 108" high
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +120/-140
 Other: 1-3/16" LAMI IGU: Exterior 1/4” Tempered x 3/8” gap x LAMI (1/4” HS x 0.075” Vanceva x 1/4” HS)
Installation Instructions
 FL19330_R4_II_Fixed 5fxt Drawings CCLI08053.pdf
 Verified By: Construction Consulting Laboratory
Test Reports
 FL19330_R4_TR_Fixed 5fxt CCLI08053.pdf
19330.2 5FXT Fixed Window 53.75" wide x 108" high, Small Missile Impact
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +120/-150
 Other: 1-3/16" LAMI IGU: Exterior 1/4” Tempered x 3/8” gap x LAMI (1/4” HS x 0.060” Saflex PVB x 1/4” HS). Small Missile Impact
Installation Instructions
 FL19330_R4_II_Fixed 5fxt Drawings CCLI08054.pdf
 Verified By: Construction Consulting Laboratory
Test Reports
 FL19330_R4_TR_Fixed 5fxt CCLI08054.pdf
19330.3 6621 Fixed Window, 60" wide x 99" high
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +80/-80
 Other: 9/16” LAMI: 1/4” HS x 0.077” Vanceva x 1/4” HS Additional Installation Req: Wood screws require 2.375” edge distance and .900” embedment.
Installation Instructions
 FL19330_R4_II_Fixed 6621 Drawings 87165.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA
Test Reports
 FL19330_R4_TR_Fixed 6621 87165.01-801-18.pdf
19330.4 6621 Fixed Window, 60" wide x 99" high
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +80/-80
 Other: 1-1/4" LAMI IGU: Exterior 1/4” HS x 7/16” gap x LAMI (1/4” HS x 0.077” Vanceva x 1/4” HS) Additional Installation Req: Wood screws require 2.375” edge distance and .900” embedment. Impact protective devices required above 30 ft of grade in HVHZ.
Installation Instructions
 FL19330_R4_II_Fixed 6621 Drawings 87165.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA
Test Reports
 FL19330_R4_TR_Fixed 6621 87165.01-801-18.pdf
19330.5 6621 Fixed Window, 60" wide x 99" high
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +70/-70
 Other: 9/16” LAMI: 1/4” HS x 0.090” Saflex x 1/4” HS Additional Installation Req: Wood screws require 2.375” edge distance and .900” embedment.
Installation Instructions
 FL19330_R4_II_Fixed 6621 Drawings 87165.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA
Test Reports
 FL19330_R4_TR_Fixed 6621 87165.01-801-18.pdf
19330.6 6621 Fixed Window, 60" wide x 99" high
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +70/-70
 Other: 1-1/4" LAMI IGU: Exterior 1/4” HS x 7/16” gap x LAMI (1/4” HS x 0. 090” Saflex x 1/4” HS) Additional Installation Req: Wood screws require 2.375” edge distance and .900” embedment. Impact protective devices required above 30 ft of grade in HVHZ.
Installation Instructions
 FL19330_R4_II_Fixed 6621 Drawings 87165.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA
Test Reports
 FL19330_R4_TR_Fixed 6621 87165.01-801-18.pdf
19330.7 6621 Fixed Window, 48" wide x 72" high
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +80/-80
 Other: 1/4" LAMI IGU: Exterior 1/4” HS x7/16” gap x LAMI (1/4” HS x 0.090” Viracon PVB x 1/4” HS) Additional Installation Req: Wood screws require 2.375” edge distance and .900” embedment. Impact protective devices required above 30 ft of grade in HVHZ.
Installation Instructions
 FL19330_R4_II_Fixed 6621 Drawings 83658.pdf
 FL19330_R4_II_FL19330_R0_II_Fixed 6621 Drawings 87165 Part A.pdf
 FL19330_R4_II_FL19330_R0_II_Fixed 6621 Drawings 87165 Part B.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA
Test Reports
 FL19330_R4_TR_Fixed 6621 836580180118.pdf
19330.8 6621 Fixed Window over Fixed Window, 66" wide x 134.5" high.
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +80/-80
 Other: 9/16” LAMI: 1/4” HS x 0.090” Saflex x 1/4” HS Additional Installation Req: Wood screws require 2” edge distance and 1 1/2” embedment.
Installation Instructions
 FL19330_R4_II_Fixed 6621 Drawings A0035.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA
Test Reports
 FL19330_R4_TR_Fixed 6621 A0035.03-801-18.pdf
 
Back   Next
 