| 19330.1 |
5FXT |
Fixed Window 53.75" wide x 108" high |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +120/-140 Other: 1-3/16" LAMI IGU: Exterior 1/4” Tempered x 3/8” gap x LAMI (1/4” HS x 0.075” Vanceva x 1/4” HS) |
Installation Instructions FL19330_R4_II_Fixed 5fxt Drawings CCLI08053.pdf Verified By: Construction Consulting Laboratory Test Reports FL19330_R4_TR_Fixed 5fxt CCLI08053.pdf |
|
|
| 19330.2 |
5FXT |
Fixed Window 53.75" wide x 108" high, Small Missile Impact |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +120/-150 Other: 1-3/16" LAMI IGU: Exterior 1/4” Tempered x 3/8” gap x LAMI (1/4” HS x 0.060” Saflex PVB x 1/4” HS). Small Missile Impact |
Installation Instructions FL19330_R4_II_Fixed 5fxt Drawings CCLI08054.pdf Verified By: Construction Consulting Laboratory Test Reports FL19330_R4_TR_Fixed 5fxt CCLI08054.pdf |
|
|
| 19330.3 |
6621 |
Fixed Window, 60" wide x 99" high |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +80/-80 Other: 9/16” LAMI: 1/4” HS x 0.077” Vanceva x 1/4” HS
Additional Installation Req: Wood screws require 2.375” edge distance and .900” embedment. |
Installation Instructions FL19330_R4_II_Fixed 6621 Drawings 87165.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL19330_R4_TR_Fixed 6621 87165.01-801-18.pdf |
|
|
| 19330.4 |
6621 |
Fixed Window, 60" wide x 99" high |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +80/-80 Other: 1-1/4" LAMI IGU: Exterior 1/4” HS x 7/16” gap x LAMI (1/4” HS x 0.077” Vanceva x 1/4” HS)
Additional Installation Req: Wood screws require 2.375” edge distance and .900” embedment. Impact protective devices required above 30 ft of grade in HVHZ. |
Installation Instructions FL19330_R4_II_Fixed 6621 Drawings 87165.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL19330_R4_TR_Fixed 6621 87165.01-801-18.pdf |
|
|
| 19330.5 |
6621 |
Fixed Window, 60" wide x 99" high |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: 9/16” LAMI: 1/4” HS x 0.090” Saflex x 1/4” HS
Additional Installation Req: Wood screws require 2.375” edge distance and .900” embedment. |
Installation Instructions FL19330_R4_II_Fixed 6621 Drawings 87165.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL19330_R4_TR_Fixed 6621 87165.01-801-18.pdf |
|
|
| 19330.6 |
6621 |
Fixed Window, 60" wide x 99" high |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: 1-1/4" LAMI IGU: Exterior 1/4” HS x 7/16” gap x LAMI (1/4” HS x 0. 090” Saflex x 1/4” HS)
Additional Installation Req: Wood screws require 2.375” edge distance and .900” embedment. Impact protective devices required above 30 ft of grade in HVHZ. |
Installation Instructions FL19330_R4_II_Fixed 6621 Drawings 87165.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL19330_R4_TR_Fixed 6621 87165.01-801-18.pdf |
|
|
| 19330.7 |
6621 |
Fixed Window, 48" wide x 72" high |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +80/-80 Other: 1/4" LAMI IGU: Exterior 1/4” HS x7/16” gap x LAMI (1/4” HS x 0.090” Viracon PVB x 1/4” HS)
Additional Installation Req: Wood screws require 2.375” edge distance and .900” embedment. Impact protective devices required above 30 ft of grade in HVHZ. |
Installation Instructions FL19330_R4_II_Fixed 6621 Drawings 83658.pdf FL19330_R4_II_FL19330_R0_II_Fixed 6621 Drawings 87165 Part A.pdf FL19330_R4_II_FL19330_R0_II_Fixed 6621 Drawings 87165 Part B.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL19330_R4_TR_Fixed 6621 836580180118.pdf |
|
|
| 19330.8 |
6621 |
Fixed Window over Fixed Window, 66" wide x 134.5" high. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +80/-80 Other: 9/16” LAMI: 1/4” HS x 0.090” Saflex x 1/4” HS
Additional Installation Req: Wood screws require 2” edge distance and 1 1/2” embedment. |
Installation Instructions FL19330_R4_II_Fixed 6621 Drawings A0035.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL19330_R4_TR_Fixed 6621 A0035.03-801-18.pdf |