Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL29230-R3
Application Type Editorial Change
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Window Craftsmen Inc.
Address/Phone/Email 6031 Clark Center Avenue
Sarasota, FL 34238
(941) 922-1844
windowcraftsmen@gmail.com
 
Authorized Signature ben jakubauskas
windowcraftsmen@gmail.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Windows
Subcategory Casement
 
Compliance Method Certification Mark or Listing
 
Certification Agency National Accreditation & Management Institute
Validated By National Accreditation & Management Institute
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA 101/I.S.2/A440-082008
AAMA 101/I.S.2/A440-112011
ASTM E1886-13A2013
ASTM E1996-14A2014
 
Equivalence of Product Standards
Certified By

 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 10/20/2025
Date Validated 10/20/2025
Date Pending FBC Approval
Date Approved 10/21/2025
 
Summary of Products
FL # Model, Number or Name Description
29230.1 CM200 PVC Casement Non-Impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +60/-60
 Other:  
Certification Agency Certificate
 FL29230_R3_C_CAC_NI014327.01-R2.pdf
Quality Assurance Contract Expiration Date
 07/31/2031
Installation Instructions
 FL29230_R3_II_PVC Casement details.pdf
 Verified By: Mark A Smith FL55511
 Created by Independent Third Party: Yes
Evaluation Reports
 FL29230_R3_AE_COI.pdf
 FL29230_R3_AE_PWC Casement Eval.pdf
 Created by Independent Third Party: Yes
29230.2 CM200/201 PVC Casement Impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other:  
Certification Agency Certificate
 FL29230_R3_C_CAC_NI014327-R2.pdf
 FL29230_R3_C_CAC_NI014328-R2.pdf
Quality Assurance Contract Expiration Date
 07/31/2031
Installation Instructions
 FL29230_R3_II_PVC Casement Impact details.pdf
 Verified By: Mark A Smith FL55511
 Created by Independent Third Party: Yes
Evaluation Reports
 FL29230_R3_AE_COI.pdf
 FL29230_R3_AE_PWC Casement Impact Eval.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 