| 29241.1 |
a. Millwork 360 "Impact" Fiberglass Door |
Up to a 3'6 x 8'0 "Impact" Opaque Fiberglass Door with "Impact" Sidelite - (XO or OX Configurations) Inswing or Outswing |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 29241.1 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. |
Installation Instructions FL29241_R4_II_(g) Inst 29241.1.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL29241_R4_AE_(h) Eval 29241.1.pdf Created by Independent Third Party: Yes |
|
|
| 29241.2 |
b. Millwork 360 "Impact" Fiberglass Door |
Up to a 3'6 x 8'0 "Impact" Opaque Fiberglass Door with "Impact" Sidelite and Transom - (O/X, O/XO or O/OX Configurations) Inswing or Outswing |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 29241.2 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. |
Installation Instructions FL29241_R4_II_(g) Inst 29241.2.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL29241_R4_AE_(h) Eval 29241.2.pdf Created by Independent Third Party: Yes |
|
|
| 29241.3 |
c. Millwork 360 "Impact" Fiberglass Door |
Up to a 3'6 x 8'0 "Impact" Opaque Fiberglass Door (X Configuration) Inswing or Outswing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 29241.3 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. |
Installation Instructions FL29241_R4_II_(g) Inst 29241.3.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL29241_R4_AE_(h) Eval 29241.3.pdf Created by Independent Third Party: Yes |
|
|
| 29241.4 |
d. Millwork 360 "Impact" Fiberglass Door |
Up to a 6'0 x 8'0 "Impact" Opaque Fiberglass Door with or without "Impact" Fiberglass Sidelites - Insulated Glass (XX or OXXO Configurations) Inswing or Outswing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 29241.4 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. |
Installation Instructions FL29241_R4_II_(g) Inst 29241.4.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL29241_R4_AE_(h) Eval 29241.4.pdf Created by Independent Third Party: Yes |
|
|
| 29241.5 |
e. Millwork 360 "Impact" Fiberglass Door |
Up to a 6'0 x 8'0 "Impact" Opaque Fiberglass Door with or without "Impact" Direct Set Sidelites - Insulated Glass (XX or OXXO Configurations) Inswing or Outswing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 29241.5 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. |
Installation Instructions FL29241_R4_II_(h) Inst 29241.5.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL29241_R4_AE_(h) Eval 29241.5.pdf Created by Independent Third Party: Yes |
|
|
| 29241.6 |
f. Millwork 360 "Impact" Fiberglass Door |
Up to a 6'0 x 8'0 "Impact" Opaque Fiberglass Door with or without "Impact" Direct Set Sidelites - Insulated Glass (XX or OXXO Configurations) Inswing or Outswing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 29241.6 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. |
Installation Instructions FL29241_R4_II_(h) Inst 29241.6.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL29241_R4_AE_(h) Eval 29241.6.pdf Created by Independent Third Party: Yes |