Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL3162-R8
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer ATAS International, Inc.
Address/Phone/Email 6612 Snowdrift Road
Allentown, PA 18106
(610) 395-8445   Ext 223
jbush@atas.com
 
Authorized Signature james bush
jbush@atas.com
 
Technical Representative James E. Bush
Address/Phone/Email ATAS International, Inc.
6612 Snowdrift Road
Allentown, PA 18106
jbush@atas.com
 
Quality Assurance Representative James Bush
Address/Phone/Email 6612 Snowdrift Road
Allentown, PA 18106
jbush@atas.com
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Russel N. Emery
Florida License PE-71060
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2026
Validated By Steven M. Urich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL3162_R8_COI_Certificate of Independence - ScanRoof 3162.pdf
FL3162_R8_COI_Certificate of Independence - TechoTile 3162.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ADM12020
S1002023
TAS 1252023
UL18972015
UL5802006
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL3162_R8_Equiv_ATAS FBC Product Approval Document - ScanRoof.pdf
FL3162_R8_Equiv_ATAS FBC Product Approval Document - TechoTile.pdf
 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 01/28/2024
Date Validated 02/19/2024
Date Pending FBC Approval 03/06/2024
Date Approved 04/16/2024
 
Summary of Products
FL # Model, Number or Name Description
3162.1 ScanRoof ScanRoof SCP163
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: See evaluation report and installation instructions for allowable pressures
Installation Instructions
 FL3162_R8_II_(FMTECS-07) SCP Scan Roof Florida Building Code_01_11-14-23.pdf
 Verified By: Russel N. Emery P.E. 71060
 Created by Independent Third Party: Yes
Evaluation Reports
 FL3162_R8_AE_ATAS FBC Product Approval Document - ScanRoof.pdf
 Created by Independent Third Party: Yes
3162.2 Techo Tile Simulated spanish "S" tile
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: See installation guide and evaluation report for fastening schedule and related design pressures. Minimum roof slope 3:12.
Installation Instructions
 FL3162_R8_II_(FMTECS-01) Techo Tile Florida Building Code_01_11-14-23.pdf
 Verified By: Russel N. Emery PE-71060
 Created by Independent Third Party: Yes
Evaluation Reports
 FL3162_R8_AE_ATAS FBC Product Approval Document - TechoTile.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex