FL # FL21965-R4
Application Type Revision
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Sierra Pacific Windows
Address/Phone/Email 11605 Reading Road
PO Box 8489
Red Bluff, CA 96080
(715) 748-1716
jgouza@spi-ind.com
 
Authorized Signature Gouza Jessica
jgouza@spi-ind.com
 
Technical Representative Cheryl Wibben
Address/Phone/Email 575 S Whelen Ave
Medford, WI 54451
(715) 748-1742
cwibben@spi-ind.com
 
Quality Assurance Representative Jessica Gouza
Address/Phone/Email 575 S Whelen Ave
Medford, WI 54451
(715) 748-1716
jgouza@spi-ind.com
 
Category Windows
Subcategory Fixed
 
Compliance Method Certification Mark or Listing
 
Certification Agency Window and Door Manufacturer Association
Validated By Window and Door Manufacturers Association
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA-450-102010
AAMA/WDMA/CSA 101/I.S.2/A440-112011
ASTM E1886-132013
ASTM E1996-142014
 
Equivalence of Product Standards
Certified By

Approved Certification Agency
FL21965_R4_Equiv_2016-01 Rev 2 Tech Bulletin E1996 and E1886 Equivalency.pdf
 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 11/20/2023
Date Validated 01/23/2024
Date Pending FBC Approval
Date Approved 02/01/2024
Date Revised 07/16/2026
 
Summary of Products
FL # Model, Number or Name Description
21965.1 Aluminum Clad Direct Set Aluminum Clad Direct Set Corner Unit 51"/51"x 72.25" with Corner Post
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-65
 Other: Complies with ASTM E1300 requirements.
Certification Agency Certificate
 FL21965_R4_C_CAC_436-523.29 CCL.pdf
Quality Assurance Contract Expiration Date
 07/15/2025
Installation Instructions
 FL21965_R4_II_Clad ES DIRECT SET MULL 90 Degree CORNER CCL 436 H 523 29 ESP020370P 1741 Updated 1-21-19.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21965.2 Clad Direct Glaze Plus Clad Direct Glaze Plus 60"x 120"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Complies with ASTM E1300 requirements.
Certification Agency Certificate
 FL21965_R4_C_CAC_429-H-519.13.pdf
Quality Assurance Contract Expiration Date
 06/12/2028
Installation Instructions
 FL21965_R4_II_429-H-519.12-.15 C-DGP Nail Fin Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21965.3 Clad Direct Glaze Plus Clad Direct Glaze Plus 120"x 72"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +40/-40
 Other: Complies with ASTM E1300 requirements.
Certification Agency Certificate
 FL21965_R4_C_CAC_436-519.17 CCL.pdf
Quality Assurance Contract Expiration Date
 06/12/2028
Installation Instructions
 FL21965_R4_II_429-H-519.16-.19 C-DGP Nail Fin Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21965.4 Clad Direct Glaze Plus-Mullion Clad Direct Set Plus Mullion
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-35
 Other: AAMA 450 mulled fenestration.
Certification Agency Certificate
 FL21965_R4_C_CAC_429-519.24 CCL.pdf
Quality Assurance Contract Expiration Date
 12/06/2028
Installation Instructions
 FL21965_R4_II_429-H-519.24-.25 C-DGP Nail Fin Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21965.5 Clad Direct Glaze Plus-Mullion Clad Direct Glaze Plus-Mullion
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: AAMA 450 mulled fenestration.
Certification Agency Certificate
 FL21965_R4_C_CAC_429-519.25 CCL.pdf
Quality Assurance Contract Expiration Date
 12/06/2028
Installation Instructions
 FL21965_R4_II_429-H-519.24-.25 C-DGP Nail Fin Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21965.6 Clad Direct Glaze Plus-Mullion Clad Direct Glaze Plus-Mullion
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-35
 Other: AAMA 450 mulled fenestration.
Certification Agency Certificate
 FL21965_R4_C_CAC_429-519.26 CCL.pdf
Quality Assurance Contract Expiration Date
 10/09/2028
Installation Instructions
 FL21965_R4_II_429-H-519.26-.27 C-DGP Nail Fin Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21965.7 Clad Direct Glaze Plus-Mullion Clad Direct Glaze Plus-Mullion
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: AAMA 450 mulled fenestration.
Certification Agency Certificate
 FL21965_R4_C_CAC_429-519.27 CCL.pdf
Quality Assurance Contract Expiration Date
 10/09/2028
Installation Instructions
 FL21965_R4_II_429-H-519.26-.27 C-DGP Nail Fin Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21965.8 Clad Direct Glaze Plus-Mullion Clad Direct Glaze Plus-Mullion
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +45/-45
 Other: AAMA 450 mulled fenestration.
Certification Agency Certificate
 FL21965_R4_C_CAC_436-519.20 CCL.pdf
Quality Assurance Contract Expiration Date
 02/20/2028
Installation Instructions
 FL21965_R4_II_429-H-519.20-.21 C-DGP Nail Fin Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21965.9 Clad Direct Glaze Plus-Mullion Clad Direct Glaze Plus-Mullion
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +55/-55
 Other: AAMA 450 mulled fenestration.
Certification Agency Certificate
 FL21965_R4_C_CAC_436-519.21 CCL.pdf
Quality Assurance Contract Expiration Date
 02/20/2028
Installation Instructions
 FL21965_R4_II_429-H-519.20-.21 C-DGP Nail Fin Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21965.10 Clad Direct Glaze Plus-Mullion Clad Direct Glaze Plus-Mullion
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-35
 Other: AAMA 450 mulled fenestration.
Certification Agency Certificate
 FL21965_R4_C_CAC_436-519.22 CCL.pdf
Quality Assurance Contract Expiration Date
 10/20/2028
Installation Instructions
 FL21965_R4_II_429-H-519.22-.23 C-DGP Nail Fin Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21965.11 Clad Direct Glaze Plus-Mullion Clad Direct Glaze Plus-Mullion
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: AAMA 450 mulled fenestration.
Certification Agency Certificate
 FL21965_R4_C_CAC_436-519.23 CCL.pdf
Quality Assurance Contract Expiration Date
 10/20/2028
Installation Instructions
 FL21965_R4_II_429-H-519.22-.23 C-DGP Nail Fin Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21965.12 FeelSafe H3 2.0 Casement Transom FeelSafe H3 2.0 3-Wide Casement Transom 119.5"x27.5" (40"x28" individual unit call out)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-60
 Other: Qualifies individual or multi-wide units with individual unit call out of 40"x28"; Requires mull clips; Glass make-up consists of Type LL (1" Insul--3.1mm AN/.090"PVB/3.1mm AN; 13mm XL Edge Spacer; 3.1mm AN Int Lite); Complies with ASTM E1300 requirements.
Certification Agency Certificate
 FL21965_R4_C_CAC_436-H-660.79-.81CCL.pdf
Quality Assurance Contract Expiration Date
 10/21/2026
Installation Instructions
 FL21965_R4_II_H3 2.0 Feelsafe CA Transom 3-WIDE 120x28 CCL_436-H-660.79-.81 ESP024129P_2073 8.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21965.13 Vinyl Builders Fixed Vinyl Builders Single Hung Fixed 3-Wide 30"/60"/30"x60"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-35
 Other: Maximum frame size 96"x60"; Through frame installation; Complies with ASTM E1300 requirements.
Certification Agency Certificate
 FL21965_R4_C_CAC_448-H-011.02 CCL.pdf
Quality Assurance Contract Expiration Date
 01/03/2027
Installation Instructions
 FL21965_R4_II_8500 Vinyl Builders SH Fixed 3W CCL 448-H-011_02 ESP024666P-2107.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21965.14 Vinyl Casement Picture Vinyl Casement Picture Mull 95.5"x 95.5" (47.5"x 95.5")
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +40/-40
 Other: Complies with ASTM E1300 requirements.
Certification Agency Certificate
 FL21965_R4_C_CAC_448-004.28.pdf
Quality Assurance Contract Expiration Date
 03/21/2029
Installation Instructions
 FL21965_R4_II_8000 Vinyl CA PIC-PIC 1W-48X96 2W-96X96 CCL 448-H-004_27-28 ESP030570P-2419_1.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21965.15 Vinyl Casement Picture Vinyl Casement Picture Stack 65.5"x 65.5"/23.5"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Complies with ASTM E1300 requirements.
Certification Agency Certificate
 FL21965_R4_C_CAC_448-004.33.pdf
Quality Assurance Contract Expiration Date
 03/21/2029
Installation Instructions
 FL21965_R4_II_8000 Vinyl CA Fixed-Fixed Stacked 66x90oa CCL 448-H-004_32-33 ESP030570P-2419_3.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21965.16 Vinyl Casement Picture Vinyl Casement Picture 59.5"x 71.5"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Complies with ASTM E1300 requirements.
Certification Agency Certificate
 FL21965_R4_C_CAC_448-009.03.pdf
Quality Assurance Contract Expiration Date
 02/04/2029
Installation Instructions
 FL21965_R4_II_8000 Vinyl CA PIC 1W-60X72 CCL 448-H-009_02-04 ESP030274P-2402.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21965.17 Vinyl Casement Picture Vinyl Casement Picture Combination 95.5"x 95.5" Overall
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +45/-45
 Other: Complies with ASTM E1300 requirements.
Certification Agency Certificate
 FL21965_R4_C_CAC_448-009-.7.pdf
Quality Assurance Contract Expiration Date
 03/22/2029
Installation Instructions
 FL21965_R4_II_8000 Vinyl CA Stacked-Mulled 96x96oa CCL448-H-009_07-11 ESP030570P-2419_2.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex