Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL21966-R3
Application Type Affirmation
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Sierra Pacific Windows
Address/Phone/Email 11605 Reading Road
PO Box 8489
Red Bluff, CA 96080
(715) 748-1716
jgouza@spi-ind.com
 
Authorized Signature Gouza Jessica
jgouza@spi-ind.com
 
Technical Representative Cheryl Wibben
Address/Phone/Email 575 S Whelen Ave
Medford, WI 54451
(715) 748-1742
cwibben@spi-ind.com
 
Quality Assurance Representative Jessica Gouza
Address/Phone/Email 575 S Whelen Ave
Medford, WI 54451
(715) 748-1716
jgouza@spi-ind.com
 
Category Windows
Subcategory Casement
 
Compliance Method Certification Mark or Listing
 
Certification Agency Window and Door Manufacturer Association
Validated By Window and Door Manufacturers Association
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA 101/I.S.2/A440-082008
AAMA/WDMA/CSA 101/I.S.2/A440-112011
ASTM E18862013
ASTM E19962014
CSA A440S1-092009
 
Equivalence of Product Standards
Certified By

Approved Certification Agency
FL21966_R3_Equiv_2016-01 Rev 2 Tech Bulletin E1996 and E1886 Equivalency.pdf
 
 
 
Documentation from approved Evaluation or Validation Entity
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 08/24/2023
Date Validated 08/24/2023
Date Pending FBC Approval
Date Approved 09/09/2023
 
Summary of Products
FL # Model, Number or Name Description
21966.1 FeelSafe H3 2.0 Casement FeelSafe H3 2.0 Casement 3-Wide Operator 105.5"x71.5" (35.5"x71.5" individual unit size)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-60
 Other: Qualifies individual or multi-wide units with a maximum individual frame size of 35.5"x71.5"; Requires mull clips; Glass make-up consists of Type LL (1" Insul--3.1mm AN/.090"PVB/3.1mm AN; 13mm XL Edge Spacer; 3.1mm AN Int Lite); Complies with ASTM E1300 requirements.
Certification Agency Certificate
 FL21966_R3_C_CAC_436-H-660.70 CCL.pdf
Quality Assurance Contract Expiration Date
 10/25/2026
Installation Instructions
 FL21966_R3_II_H3 2.0 Feelsafe CA OP 3-WIDE 106x72 CCL_436_H_660.70 .72 ESP024129P_2073 1.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21966.2 FeelSafe H3 2.0 Casement FeelSafe H3 2.0 Casement Oper/Pict/Oper w/3-Wide FeelSafe H3 2.0 Casement Transom 119.5"x99"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-60
 Other: Qualifies individual/multi-wide and stacked unit w/max unit size 31.25"x71.5" oper, 57"x71.5" pict, 31.25"x27.5" transom; Requires mull clips, 1/4" steel horiz mull plate; Glass make-up consists of Type LL (1"Insul-3.1mm AN/.090"PVB/3.1mm AN; 13mm XL Edge Spacer; 3.1mm AN Int Lite) for oper and transom and Type MM (1" Insul-3.9mm An/.090"SGP/3.9mm An; 9.8mm XL Edge Spacer; 4.7mm AN Int Lite) for pict; Complies with ASTM E1300 requirements.
Certification Agency Certificate
 FL21966_R3_C_CAC_436-H-660.73 CCL.pdf
Quality Assurance Contract Expiration Date
 10/21/2026
Installation Instructions
 FL21966_R3_II_H3 2.0 Feelsafe CA Op_Pic_Op 3-Wide 2-High 119.5x99 CCL_436-H-660.73-.75 ESP024129P_2073 11.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21966.3 FeelSafe H3 2.0 Casement FeelSafe H3 2.0 Casement Operator/Picture/Operator 119.5"x71.5"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-60
 Other: Qualifies individual or multi-wide with maximum operator unit size of 31.25"x71.5" and picture size of 57"x71.5"; Requires mull clips; Glass make-up consists of Type LL (1" Insul--3.1mm AN/.090"PVB/3.1mm AN; 13mm XL Edge Spacer; 3.1mm AN Int Lite) for operator and Type MM (1" Insul--3.9mm An/.090"SGP/3.9mm An; 9.8mm XL Edge Spacer; 4.7mm AN Int Lite) for picture; Complies with ASTM E1300 requirements.
Certification Agency Certificate
 FL21966_R3_C_CAC_436-H-660.76 CCL.pdf
Quality Assurance Contract Expiration Date
 10/26/2026
Installation Instructions
 FL21966_R3_II_H3 2.0 Feelsafe CA OP-Pic-Op 3-WIDE 120x72 CCL_436-H-660.76-.78 ESP024129P_2073 5.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21966.4 FeelSafe H3 2.0 Casement FeelSafe H3 2.0 Casement 2-Wide Mulled (35.5"x83.5" individual unit size)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-60
 Other: Qualifies individual or multi-wide units with a maximum individual frame size of 35.5"x83.5"; Requires mull clips and 1/4" aluminum vertical mull plate; Glass make-up consists of Type LL (1" Insul--3.1mm AN/.090"PVB/3.1mm AN; 13mm XL Edge Spacer; 3.1mm AN Int Lite); Complies with ASTM E1300 requirements.
Certification Agency Certificate
 FL21966_R3_C_CAC_436-H-660.82 CCL (1).pdf
Quality Assurance Contract Expiration Date
 10/26/2026
Installation Instructions
 FL21966_R3_II_H3 2.0 Feelsafe CA OP 1-Wide 36x84 and 2-WIDE 71.75x84 CCL_436-H-660.82-.84 ESP024129P_2073 12.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21966.5 H3 2.0 Casement H3 2.0 Casement Oper/Fixed/Oper w/H3 2.0 Casement 3-Wide Transom 106"x99" (36"x72"/36"x28" individual frame sizes) HP
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Maximum individual frame size 36"x72"/36"x28"; Requires 1/4" steel horizontal mull plate and mull clips; Complies with ASTM E1300 requirements.
Certification Agency Certificate
 FL21966_R3_C_CAC_436-H-660.85 CCL.pdf
Quality Assurance Contract Expiration Date
 03/28/2026
Installation Instructions
 FL21966_R3_II_H3 2.0 CA OP 3-WIDE 2 HIGH 106x99 CCL 436-H-660.85 ESP023931P_2053 Rev A.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21966.6 H3 2.0 Casement H3 2.0 Casement 3-Wide Oper/Fixed/ Oper w/H3 2.0 Casement 3-Wide Transom 106"x95 (36"x72"/36"x24" individual unit size)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +25/-25
 Other: Qualifies individual to 3-wide w/stack maximum unit size 106"x72"; Complies with ASTM E1300 requirements.
Certification Agency Certificate
 FL21966_R3_C_CAC_436-H-660.40 CCL.pdf
Quality Assurance Contract Expiration Date
 03/28/2026
Installation Instructions
 FL21966_R3_II_H3 2.0 CA OP 3-WIDE 2 HIGH 106x95 CCL 436_H_660.40 ESP023329P_1997.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21966.7 H3 2.0 Casement H3 2.0 Casement 2-Wide with H3 2.0 2-Wide Casement Transom 71"x95" (36"x72"/36"x24" individual unit size) HP
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +45/-45
 Other: Qualifies single or 2-wide with matching transom maximum frame size 36"x72"/36"x24"; Requires mull clips; Complies with ASTM E1300 requirements.
Certification Agency Certificate
 FL21966_R3_C_CAC_436-H-660.44 CL.pdf
Quality Assurance Contract Expiration Date
 03/28/2026
Installation Instructions
 FL21966_R3_II_H3 2.0 CA OP 2-WIDE 2 HIGH 71x95 CCL 436_H_660.44 ESP023258P_1989.1.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21966.8 H3 2.0 Casement H3 2.0 Casement 2-Wide with H3 2.0 Casement 2-Wide Transom 71"x95" (36"x72"/36"x24" individual unit size) Standard
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-35
 Other: Qualifies single or 2-wide with matching transom maximum frame size 36 "x72"/36"x24"; Complies with ASTM E1300 requirements.
Certification Agency Certificate
 FL21966_R3_C_CAC_436-H-660.42 CCL.pdf
Quality Assurance Contract Expiration Date
 03/28/2026
Installation Instructions
 FL21966_R3_II_H3 2.0 CA OP 2-WIDE 2 HIGH 71x95 CCL 436_H_660.42 ESP023258P_1989.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
21966.9 Vinyl Casement Vinyl Casement 3-Wide Common Mull 106"x72" (36"x72" individual unit size)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-35
 Other: Qualifies 2-wide and 3-wide with maximum individual frame size of 36"x72"; Complies with ASTM E1300 requirements.
Certification Agency Certificate
 FL21966_R3_C_CAC_448-H-004.15 CCL.pdf
Quality Assurance Contract Expiration Date
 01/05/2027
Installation Instructions
 FL21966_R3_II_SS 8000 Vinyl CA OP-PIC-OP 3W CCL 448-H-004_15 ESP024429P-2086.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824