FL # FL6617-R9
Application Type Editorial Change
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Behlen Mfg. Co --- formerly Trident Building Systems
Address/Phone/Email 2812 Tallevast Road
Sarasota, FL 34243
(941) 755-7073
wes.young@behlenedge.com
 
Authorized Signature Scott Close
sclose@tridentbuildingsystems.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Structural Components
Subcategory Roof Deck
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Scott D. Close
Florida License PE-65849
Quality Assurance Entity Applied Testing and Geosciences
Quality Assurance Contract Expiration Date 12/31/2027
Validated By Locke Bowden P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL6617_R9_COI_Certificate of Independence-EVALUATOR.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E15922005
FM 44711992
TAS 1252003
TAS 2011994
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 12/02/2024
Date Validated 12/04/2024
Date Pending FBC Approval 12/27/2024
Date Approved 02/11/2025
 
Summary of Products
FL # Model, Number or Name Description
6617.1 PBR Roof Panel 26 Ga. PBR Roof Panel over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-351.0
 Other: -56.0 psf @ 5'-0" o.c. -351.0 psf @ 2'-0" o.c. Install per manufacturer's details.
Installation Instructions
 FL6617_R9_II_PBR Installation Manual.pdf
 Verified By: Scott D. Close 65849
 Created by Independent Third Party: Yes
Evaluation Reports
 FL6617_R9_AE_PBR 26GA ROOF (NON HVHZ)-EVAL REPORT (FBC 2023).pdf
 Created by Independent Third Party: Yes
6617.2 PBR Roof Panel (HVHZ) 24 Ga. PBR Roof Panel over Open Framing
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +N/A/-145.0
 Other: -37.6 psf @ 5'-0" o.c. -145.0 psf @ 2'-0" o.c. Install per manufacturer's details.
Installation Instructions
 FL6617_R9_II_PBR Installation Manual.pdf
 Verified By: Scott D. Close 65849
 Created by Independent Third Party: Yes
Evaluation Reports
 FL6617_R9_AE_PBR 24GA ROOF (HVHZ)-EVAL REPORT (FBC 2023).pdf
 Created by Independent Third Party: Yes
6617.3 SurLok Roof Panel 24 Ga. SurLok Roof Panel over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-136.4psf
 Other: -56.6 psf @ 5'-0" o.c. -136.4 psf @ 2'-0" o.c. Install per manufacturer's details.
Installation Instructions
 FL6617_R9_II_SURLOK INSTALL NON HVHZ.pdf
 Verified By: Scott D. Close 65849
 Created by Independent Third Party: Yes
Evaluation Reports
 FL6617_R9_AE_SURLOK 24GA ROOF (NON HVHZ)-EVAL REPORT (FBC 2023).pdf
 Created by Independent Third Party: Yes
6617.4 SurLok Roof Panel (HVHZ) 24 Ga. SurLok Roof Panel over Open Framing
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +N/A/-160.0
 Other: -55.0 psf @ 5'-0" o.c. -160.0 psf @ 1'-0" o.c. Install per manufacturer's details.
Installation Instructions
 FL6617_R9_II_SURLOK INSTALL HVHZ.pdf
 Verified By: Scott D. Close 65849
 Created by Independent Third Party: Yes
Evaluation Reports
 FL6617_R9_AE_SURLOK 24GA ROOF (HVHZ)-EVAL REPORT (FBC 2023).pdf
 Created by Independent Third Party: Yes
6617.5 SurLok Roof Panel Curved 24 Ga. Curved SurLok Roof Panel over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-150.0
 Other: -30.0 psf @ 5'-0" o.c. -150.0 psf @ 1'-0" o.c. Install per manufacturer's details.
Installation Instructions
 FL6617_R9_II_SURLOK INSTALL NON HVHZ.pdf
 Verified By: Scott D. Close 65849
 Created by Independent Third Party: Yes
Evaluation Reports
 FL6617_R9_AE_CURVED SURLOK 24GA ROOF (NON HVHZ)-EVAL REPORT (FBC 2023).pdf
 Created by Independent Third Party: Yes
 
Back   Next
 