| 6617.1 |
PBR Roof Panel |
26 Ga. PBR Roof Panel over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-351.0 Other: -56.0 psf @ 5'-0" o.c. -351.0 psf @ 2'-0" o.c. Install per manufacturer's details. |
Installation Instructions FL6617_R9_II_PBR Installation Manual.pdf Verified By: Scott D. Close 65849 Created by Independent Third Party: Yes Evaluation Reports FL6617_R9_AE_PBR 26GA ROOF (NON HVHZ)-EVAL REPORT (FBC 2023).pdf Created by Independent Third Party: Yes |
|
|
| 6617.2 |
PBR Roof Panel (HVHZ) |
24 Ga. PBR Roof Panel over Open Framing |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +N/A/-145.0 Other: -37.6 psf @ 5'-0" o.c. -145.0 psf @ 2'-0" o.c. Install per manufacturer's details. |
Installation Instructions FL6617_R9_II_PBR Installation Manual.pdf Verified By: Scott D. Close 65849 Created by Independent Third Party: Yes Evaluation Reports FL6617_R9_AE_PBR 24GA ROOF (HVHZ)-EVAL REPORT (FBC 2023).pdf Created by Independent Third Party: Yes |
|
|
| 6617.3 |
SurLok Roof Panel |
24 Ga. SurLok Roof Panel over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-136.4psf Other: -56.6 psf @ 5'-0" o.c. -136.4 psf @ 2'-0" o.c. Install per manufacturer's details. |
Installation Instructions FL6617_R9_II_SURLOK INSTALL NON HVHZ.pdf Verified By: Scott D. Close 65849 Created by Independent Third Party: Yes Evaluation Reports FL6617_R9_AE_SURLOK 24GA ROOF (NON HVHZ)-EVAL REPORT (FBC 2023).pdf Created by Independent Third Party: Yes |
|
|
| 6617.4 |
SurLok Roof Panel (HVHZ) |
24 Ga. SurLok Roof Panel over Open Framing |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +N/A/-160.0 Other: -55.0 psf @ 5'-0" o.c. -160.0 psf @ 1'-0" o.c. Install per manufacturer's details. |
Installation Instructions FL6617_R9_II_SURLOK INSTALL HVHZ.pdf Verified By: Scott D. Close 65849 Created by Independent Third Party: Yes Evaluation Reports FL6617_R9_AE_SURLOK 24GA ROOF (HVHZ)-EVAL REPORT (FBC 2023).pdf Created by Independent Third Party: Yes |
|
|
| 6617.5 |
SurLok Roof Panel Curved |
24 Ga. Curved SurLok Roof Panel over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-150.0 Other: -30.0 psf @ 5'-0" o.c. -150.0 psf @ 1'-0" o.c. Install per manufacturer's details. |
Installation Instructions FL6617_R9_II_SURLOK INSTALL NON HVHZ.pdf Verified By: Scott D. Close 65849 Created by Independent Third Party: Yes Evaluation Reports FL6617_R9_AE_CURVED SURLOK 24GA ROOF (NON HVHZ)-EVAL REPORT (FBC 2023).pdf Created by Independent Third Party: Yes |