| 39169.1 |
1. Roll Up Shutter System with CHD-6 Slat (End Retention) NonHVHZ |
Extruded aluminum slats interlocked together thru knuckles and retained by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +varies/-varies Other: Large missile level "D" wind zones 1, 2, 3 and 4 (basic protection only). ASD Pressure rating: +/- 30 psf at 21'-8" span (wall mounted) and +/- 140 psf at 7'-9" span (wall mounted) with 3/8" slip. See sheets 13 and 18 of installation drawing for additional pressures and spans. See Section 7 of Prod Eval Report for additional limitations and conditions of use. |
Installation Instructions FL39169_R2_II_PED Drwg 23-086 RollingShield.pdf Verified By: Walter A. Tillit Jr., P.E. PE 44167 Created by Independent Third Party: Yes Evaluation Reports FL39169_R2_AE_PER Drwg 23-086 RollingShield.pdf Created by Independent Third Party: Yes |
|
|
| 39169.2 |
2. Roll Up Shutter System with End Retention 55mm Slat Large Missile Impact Resistant Non HVHZ |
Extruded aluminum slats interlocked together thru knuckles and retained by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +varies/-varies Other: Large missile (basic protection only). For ASD pressure rating, reference Sheets 13 through 15 of the installation drawing. |
Installation Instructions FL39169_R2_II_PED Drwg 23-120 RollingShield.pdf Verified By: Walter A. Tillit Jr., P.E. PE 44167 Created by Independent Third Party: Yes Evaluation Reports FL39169_R2_AE_PER Drwg 23-120 RollingShield.pdf Created by Independent Third Party: Yes |
|
|
| 39169.3 |
3. Fabric End Retention Roll Up Shutter large Missile Impact Resistant Non HVHZ |
Fabric Curtain retained by Aluminum tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +varies/-varies Other: Large missile (50 ft/sec). Pressure rating: As per sheet 9 of installation drawing & limitations per item (7) of Evaluation Report. |
Installation Instructions FL39169_R2_II_PED Drwg 26-038 RollingShield.pdf Verified By: Walter A. Tillit Jr., P.e. PE 44167 Created by Independent Third Party: Yes Evaluation Reports FL39169_R2_AE_PER Drwg 26-038 RollingShield.pdf Created by Independent Third Party: Yes |