| 45203.1 |
01: 26ga 50ALLV on plywood |
26ga (min) 50ALLV on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-86 Other: See evaluation report. |
Installation Instructions FL45203_R1_II_26ga_5V_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL45203_R1_AE_26ga_5V_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 45203.2 |
02: 26ga 50ALLV on plywood |
26ga (min) 50ALLV on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-228 Other: See evaluation report. |
Installation Instructions FL45203_R1_II_26ga_5V_plywood_b.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL45203_R1_AE_26ga_5V_plywood_b.pdf Created by Independent Third Party: Yes |
|
|
| 45203.3 |
03: 032 50ALLV on plywood |
Nominally 0.032" aluminum or thicker 50ALLV on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-168.5 Other: See evaluation report. |
Installation Instructions FL45203_R1_II_032_5V_21in_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL45203_R1_AE_032_5V_21in_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 45203.4 |
04: 29ga ALLRIB on plywood |
29ga (min) ALLRIB on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-86 Other: See evaluation report. |
Installation Instructions FL45203_R1_II_29ga_Rib_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL45203_R1_AE_29ga_Rib_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 45203.5 |
05: 29ga ALLRIB on plywood |
29ga (min) ALLRIB on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-146 Other: See evaluation report. |
Installation Instructions FL45203_R1_II_29ga_Rib_plywood_b.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL45203_R1_AE_29ga_Rib_plywood_b.pdf Created by Independent Third Party: Yes |
|
|
| 45203.6 |
06: 29ga ALLRIB on plywood |
29ga (min) ALLRIB on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-69.25 Other: See evaluation report. |
Installation Instructions FL45203_R1_II_29ga_Rib_plywood_d.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL45203_R1_AE_29ga_Rib_plywood_d.pdf Created by Independent Third Party: Yes |
|
|
| 45203.7 |
07: 26ga PBR on plywood |
26ga (min) PBR on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-71 Other: See evaluation report. |
Installation Instructions FL45203_R1_II_26ga_PBR_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL45203_R1_AE_26ga_PBR_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 45203.8 |
08: 26ga PBR on plywood |
26ga (min) PBR on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-119.5 Other: See evaluation report. |
Installation Instructions FL45203_R1_II_26ga_PBR_plywood_b.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL45203_R1_AE_26ga_PBR_plywood_b.pdf Created by Independent Third Party: Yes |