| 4525.1 |
24 Ga. 1.0 Nail Strip |
1.0 Nail Strip 24 Ga. 16" Wide Roof Panel over 15/32" APA Rated Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5psf Other: -59.75 psf. @ 16" o.c. fastener spacing. -101.0 psf @ 6 3/4" o.c. fastener spacing. -153.5 psf @ 6 3/4" o.c. fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. |
Installation Instructions FL4525_R6_II_NRRSS FL 4525 ALL REPORTS AND INSTALL DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL4525_R6_AE_NRRSS FL 4525 ALL REPORTS AND INSTALL DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 4525.2 |
24 Ga. 1.5 Snap Lock |
1.5 Snap Lock 24 Ga. Roof Panel over APA Rated Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0psf Other: -86.0 psf @ 24" o.c. -108.5 psf @ 12" o.c. -116.0 psf @ 6" o.c. Install per manufacturer's details. For use in HVHZ Zones. |
Installation Instructions FL4525_R6_II_NRRSS FL 4525 ALL REPORTS AND INSTALL DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL4525_R6_AE_NRRSS FL 4525 ALL REPORTS AND INSTALL DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 4525.3 |
26 Ga. 3/4" Ultra Rib |
26 Ga. 3/4" Ultra Rib over APA Rated Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-159.2PSF Other: -71.75 psf @ 24" o.c. fastener pattern. -159.25 psf @ 12" o.c. fastener pattern. Install per manufacturers installation details. For use in HVHZ Zones. |
Installation Instructions FL4525_R6_II_NRRSS FL 4525 ALL REPORTS AND INSTALL DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL4525_R6_AE_NRRSS FL 4525 ALL REPORTS AND INSTALL DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 4525.4 |
26 Ga. 3/4" Ultra Rib |
26 Ga. 3/4" Rib Roof Panel over 1x4 SYP Wood Purlins over APA Rated Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-164.2psf Other: -106.75 psf @ 24" o.c. -164.25 psf @ 12" o.c. Install per manufacturers details. For use in HVHZ Zones. |
Installation Instructions FL4525_R6_II_NRRSS FL 4525 ALL REPORTS AND INSTALL DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL4525_R6_AE_NRRSS FL 4525 ALL REPORTS AND INSTALL DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 4525.5 |
26 Ga. PBR |
26 Ga. PBR Roof Panel over 1x4 SYP Wood Purlins over APA Rated Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-151.7PSF Other: -100.5 psf @ 24" o.c. -151.75 psf @ 12" o.c. Install per manufacturers installation details. For use in HVHZ Zones. |
Installation Instructions FL4525_R6_II_NRRSS FL 4525 ALL REPORTS AND INSTALL DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL4525_R6_AE_NRRSS FL 4525 ALL REPORTS AND INSTALL DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 4525.6 |
26 Ga. PBR |
26 Ga. PBR 36" Wide over APA Rated Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-154.7PSF Other: -60.5 psf @ 24" o.c. -154.75 psf @ 12" o.c. Install per manufacturers installation details. For use in HVHZ Zones. |
Installation Instructions FL4525_R6_II_NRRSS FL 4525 ALL REPORTS AND INSTALL DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL4525_R6_AE_NRRSS FL 4525 ALL REPORTS AND INSTALL DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 4525.7 |
Min. 29 Ga. 3/4" Ultra Rib |
Min. 29 Ga. 3/4" Rib over 15/32" APA Plywood and 29 Ga. over 1x4 SYP wood purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-146.0psf Other: Over Plywood-84.25 psf. @ 24" o.c. -146.0 psf @ 12" o.c. Over 1x4's -45psf@24"o.c, -175.5psf@12"o.c.-Install per manufacturers details. Not for use in HVHZ Zones. |
Installation Instructions FL4525_R6_II_NRRSS FL 4525 ALL REPORTS AND INSTALL DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL4525_R6_AE_NRRSS FL 4525 ALL REPORTS AND INSTALL DETAILS.pdf Created by Independent Third Party: Yes |