| 47786.1 |
Vivid MRF Door Mull 1W2H |
Vivid MRF Door Mull 1W2H CCL 407-H-1179.04 & .05 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25/-25 Other: Max size: 44.38" Trib Width x 71.25" Span |
Certification Agency Certificate FL47786_R1_C_CAC_Marvin407CCL 1179.pdf Quality Assurance Contract Expiration Date 02/10/2035 Installation Instructions FL47786_R1_II_00121530_0 Installation Elevations and Methods, Mull, Doors.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 47786.2 |
Vivid MRF Mull 2W1H |
Vivid MRF Mull 2W1H CCL 407-H-1179.01 & .08 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max size: 72" Trib Width x 96" Span |
Certification Agency Certificate FL47786_R1_C_CAC_Marvin407CCL 1179.pdf Quality Assurance Contract Expiration Date 03/24/2035 Installation Instructions FL47786_R1_II_00121707_0 Installation Elevations, Mull, MRF.pdf FL47786_R1_II_00121708_0 Installation Methods, Mull, MRF.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 47786.3 |
Vivid MRF Mull 2W1H |
Vivid MRF Mull 2W1H CCL 407-H-1179.02 &.07 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Max Size: 56.5" Trib Width x 96" Span |
Certification Agency Certificate FL47786_R1_C_CAC_Marvin407CCL 1179.pdf Quality Assurance Contract Expiration Date 03/24/2035 Installation Instructions FL47786_R1_II_00121707_0 Installation Elevations, Mull, MRF.pdf FL47786_R1_II_00121708_0 Installation Methods, Mull, MRF.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 47786.4 |
Vivid MRF Mull 2W2H |
Vivid MRF Mull 2W2H CCL 407-H-1179.03 & .06 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Max Size: 48.25" Trib Width x 96" Span |
Certification Agency Certificate FL47786_R1_C_CAC_Marvin407CCL 1179.pdf Quality Assurance Contract Expiration Date 03/24/2035 Installation Instructions FL47786_R1_II_00121707_0 Installation Elevations, Mull, MRF.pdf FL47786_R1_II_00121708_0 Installation Methods, Mull, MRF.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 47786.5 |
Vivid Standard Mull 2W1H |
Vivid Standard Mull 2W1H CCL 407-H-1179.00 & .09 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25/-25 Other: Max size: 72" Trib Width x 96" Span |
Certification Agency Certificate FL47786_R1_C_CAC_Marvin407CCL 1179.pdf Quality Assurance Contract Expiration Date 02/10/2035 Installation Instructions FL47786_R1_II_00143722_0 Installation Elevations, Mull, Standard.pdf FL47786_R1_II_00143723_0 Installation Methods, Mull, Standard.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |