| 47762.1 |
R & S Series Garage Door |
R & S Series Garage Door, 8'x8' Unglazed, No Strut |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +28.5/-33.8 Other: Complies with Florida Building Code. Door Size and Anchorage tables included in T1001. |
Installation Instructions FL47762_R2_II_T1001_Revision 1_260211.pdf Verified By: Kurt Dietrich 55577 Created by Independent Third Party: Yes Evaluation Reports FL47762_R2_AE_FL47762-R2 Evaluation Report R Series repanels Inc USA.pdf Created by Independent Third Party: Yes |
|
|
| 47762.2 |
R & S Series Garage Door |
R & S Series Garage Door, 8'x8' Glazed, No Strut |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +33/-39.3 Other: Complies with Florida Building Code. Glazing does not meet the impact resistant requirements for windborne debris regions. Door Size and Anchorage tables included in T1004. |
Installation Instructions FL47762_R2_II_T1004_Revision 1_260211.pdf Verified By: Kurt Dietrich 55577 Created by Independent Third Party: Yes Evaluation Reports FL47762_R2_AE_FL47762-R2 Evaluation Report R Series repanels Inc USA.pdf Created by Independent Third Party: Yes |
|
|
| 47762.3 |
R & S Series Garage Door |
R & S Series Garage Door, 18'x8' Unglazed with 5 Struts |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +19.4/-21.9 Other: Complies with Florida Building Code. Door Size and Anchorage tables included in T1003. |
Installation Instructions FL47762_R2_II_T1003_Revision 1_260211.pdf Verified By: Kurt Dietrich 55577 Created by Independent Third Party: Yes Evaluation Reports FL47762_R2_AE_FL47762-R2 Evaluation Report R Series repanels Inc USA.pdf Created by Independent Third Party: Yes |
|
|
| 47762.4 |
R & S Series Garage Door |
R & S Series Garage Door, 18'x8' Glazed with 5 Struts |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +19.4/-21.9 Other: Complies with Florida Building Code. Glazing does not meet the impact resistant requirements for windborne debris regions. Door Size and Anchorage tables included in T1005. |