| 10958.1 |
TS150 / 200 / 200-20 #2110 |
10'2" Max width. 24'1" Max height. Glazing and aluminum full view available. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +14.50/-16.40 Other: Glazing is not impact resistant and does not meet the requirements for wind-borne debris regions. |
Installation Instructions FL10958_R11_II_2110 332583-rD - CV.pdf FL10958_R11_II_363342-rP01 Drawing - CV.pdf Verified By: J. Christian Voelkel FLORIDA PE 82229 Created by Independent Third Party: Yes Evaluation Reports FL10958_R11_AE_FBC Evaluation Report TS-150 v2 - CV.pdf Created by Independent Third Party: Yes |
|
|
| 10958.2 |
TS150 / 200 / 200-20 #2111 |
10'2" Max width. 24'1" Max height. Glazing and aluminum full view available. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +24.50/-27.70 Other: Glazing is not impact resistant and does not meet the requirements for wind-borne debris regions. |
Installation Instructions FL10958_R11_II_2111 332624-rD - CV.pdf FL10958_R11_II_363342-rP01 Drawing - CV.pdf Verified By: J. Christian Voelkel FLORIDA PE 82229 Created by Independent Third Party: Yes Evaluation Reports FL10958_R11_AE_FBC Evaluation Report TS-150 v2 - CV.pdf Created by Independent Third Party: Yes |
|
|
| 10958.3 |
TS150 / 200 / 200-20 #2112 |
10'2" Max width. 24'1" Max height. Glazing and aluminum full view available. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +28.40/-32.20 Other: Glazing is not impact resistant and does not meet the requirements for wind-borne debris regions. |
Installation Instructions FL10958_R11_II_2112 332625-rD - CV.pdf FL10958_R11_II_363342-rP01 Drawing - CV.pdf Verified By: J. Christian Voelkel FLORIDA PE 82229 Created by Independent Third Party: Yes Evaluation Reports FL10958_R11_AE_FBC Evaluation Report TS-150 v2 - CV.pdf Created by Independent Third Party: Yes |
|
|
| 10958.4 |
TS150 / 200 / 200-20 #2113 |
10'2" Max width. 24'1" Max height. Glazing and aluminum full view available. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +32.60/-36.90 Other: Glazing is not impact resistant and does not meet the requirements for wind-borne debris regions. |
Installation Instructions FL10958_R11_II_2113 332626-rD - CV.pdf FL10958_R11_II_363342-rP01 Drawing - CV.pdf Verified By: J. Christian Voelkel FLORIDA PE 82229 Created by Independent Third Party: Yes Evaluation Reports FL10958_R11_AE_FBC Evaluation Report TS-150 v2 - CV.pdf Created by Independent Third Party: Yes |
|
|
| 10958.5 |
TS150 / 200 / 200-20 #2120 |
12'2" Max width. 24'1" Max height. Glazing and aluminum full view available. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +11.40/-12.70 Other: Glazing is not impact resistant and does not meet the requirements for wind-borne debris regions. |
Installation Instructions FL10958_R11_II_2120 332627-rD - CV.pdf FL10958_R11_II_363342-rP01 Drawing - CV.pdf Verified By: J. Christian Voelkel FLORIDA PE 82229 Created by Independent Third Party: Yes Evaluation Reports FL10958_R11_AE_FBC Evaluation Report TS-150 v2 - CV.pdf Created by Independent Third Party: Yes |
|
|
| 10958.6 |
TS150 / 200 / 200-20 #2122 |
12'2" Max width. 24'1" Max height. Glazing and aluminum full view available. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +28.40/-32.20 Other: Glazing is not impact resistant and does not meet the requirements for wind-borne debris regions. |
Installation Instructions FL10958_R11_II_2122 365375-r- - CV.pdf FL10958_R11_II_FBC Evaluation Report TS150 - CV.pdf Verified By: J. Christian Voelkel FLORIDA PE 82229 Created by Independent Third Party: Yes Evaluation Reports FL10958_R11_AE_FBC Evaluation Report TS-150 v2 - CV.pdf Created by Independent Third Party: Yes |
|
|
| 10958.7 |
TS150 / 200 / 200-20 #2130 |
14'2" Max width. 24'1" Max height. Glazing and aluminum full view available. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +11.40/-12.70 Other: Glazing is not impact resistant and does not meet the requirements for wind-borne debris regions. |
Installation Instructions FL10958_R11_II_2130 332629-rD - CV.pdf FL10958_R11_II_363342-rP01 Drawing - CV.pdf Verified By: J. Christian Voelkel FLORIDA PE 82229 Created by Independent Third Party: Yes Evaluation Reports FL10958_R11_AE_FBC Evaluation Report TS-150 v2 - CV.pdf Created by Independent Third Party: Yes |
|
|
| 10958.8 |
TS150 / 200 / 200-20 #2131 |
14'2" Max width. 24'1" Max height. Glazing and aluminum full view available. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +23.70/-26.60 Other: Glazing is not impact resistant and does not meet the requirements for wind-borne debris regions. |
Installation Instructions FL10958_R11_II_2131 332629-rD - CV.pdf FL10958_R11_II_363342-rP01 Drawing - CV.pdf Verified By: J. Christian Voelkel FLORIDA PE 82229 Created by Independent Third Party: Yes Evaluation Reports FL10958_R11_AE_FBC Evaluation Report TS-150 v2 - CV.pdf Created by Independent Third Party: Yes |
|
|
| 10958.9 |
TS150 / 200 / 200-20 #2140 |
16'2" Max width. 24'1" Max height. Glazing and aluminum full view available. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +11.40/-12.70 Other: Glazing is not impact resistant and does not meet the requirements for wind-borne debris regions. |
Installation Instructions FL10958_R11_II_2140 332631-rD - CV.pdf FL10958_R11_II_363342-rP01 Drawing - CV.pdf Verified By: J. Christian Voelkel FLORIDA PE 82229 Created by Independent Third Party: Yes Evaluation Reports FL10958_R11_AE_FBC Evaluation Report TS-150 v2 - CV.pdf Created by Independent Third Party: Yes |
|
|
| 10958.10 |
TS150 / 200 / 200-20 #2142 |
16'2" Max width. 24'1" Max height. Glazing and aluminum full view available. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +27.50/-31.00 Other: Glazing is not impact resistant and does not meet the requirements for wind-borne debris regions. |
Installation Instructions FL10958_R11_II_2142 332633-rD - CV.pdf FL10958_R11_II_363342-rP01 Drawing - CV.pdf Verified By: J. Christian Voelkel FLORIDA PE 82229 Created by Independent Third Party: Yes Evaluation Reports FL10958_R11_AE_FBC Evaluation Report TS-150 v2 - CV.pdf Created by Independent Third Party: Yes |
|
|
| 10958.11 |
TS150 / 200 / 200-20 #2143 |
16'2" Max width. 24'1" Max height. Glazing and aluminum full view available. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +20.90/-23.60 Other: Glazing is not impact resistant and does not meet the requirements for wind-borne debris regions. |
Installation Instructions FL10958_R11_II_2143 365376-r- - CV.pdf FL10958_R11_II_363342-rP01 Drawing - CV.pdf Verified By: J. Christian Voelkel FLORIDA PE 82229 Created by Independent Third Party: Yes Evaluation Reports FL10958_R11_AE_FBC Evaluation Report TS-150 v2 - CV.pdf Created by Independent Third Party: Yes |
|
|
| 10958.12 |
TS200 / 200-20 #2150 |
24'2" Max width. 24'1" Max height. Glazing available. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +14.00/-15.70 Other: Glazing is not impact resistant and does not meet the requirements for wind-borne debris regions. |
Installation Instructions FL10958_R11_II_2150 332634-rD - CV.pdf FL10958_R11_II_363342-rP01 Drawing - CV.pdf Verified By: J. Christian Voelkel FLORIDA PE 82229 Created by Independent Third Party: Yes Evaluation Reports FL10958_R11_AE_FBC Evaluation Report TS-150 v2 - CV.pdf Created by Independent Third Party: Yes |
|
|
| 10958.13 |
TS200 / 200-20 #2151 |
24'2" Max width. 24'1" Max height. Glazing available. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +20.9/-23.6 Other: Glazing is not impact resistant and does not meet the requirements for wind-borne debris regions. |
Installation Instructions FL10958_R11_II_2151 365337-r - - CV.pdf FL10958_R11_II_363342-rP01 Drawing - CV.pdf Verified By: J. Christian Voelkel FL License 82229 Created by Independent Third Party: Yes Evaluation Reports FL10958_R11_AE_FBC Evaluation Report TS-150 v2 - CV.pdf Created by Independent Third Party: Yes |