|
46524.1 |
310 Non-Impact Fin Frame Single Hung Window |
310 Non-Impact Fin Frame Single Hung Window |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +70/-100 Other: Please refer to the NOA for all other limitations. |
Certification Agency Certificate FL46524_R0_C_CAC_240116 15 - 310 Alum SH Fin.pdf Quality Assurance Contract Expiration Date 07/07/2025 Installation Instructions FL46524_R0_II_240116 15 - 310 Alum SH Fin.pdf Verified By: Thomas J. Sotos, P.E. 55225 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: |
|
46524.2 |
310 Non-Impact Flange Frame Single Hung Window |
310 Non-Impact Flange Frame Single Hung Window |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +70/-100 Other: Please refer to the NOA for all other limitations. |
Certification Agency Certificate FL46524_R0_C_CAC_240116 14 - 310 Alum SH Fl.pdf Quality Assurance Contract Expiration Date 09/01/2025 Installation Instructions FL46524_R0_II_240116 14 - 310 Alum SH Fl.pdf Verified By: Thomas J. Sotos, P.E. 55225 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: |
|
46524.3 |
7100 Impact, Fin Frame Single Window |
7100 Impact, Fin Frame Single Window |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: Please refer to the NOA for all other limitations. |
Certification Agency Certificate FL46524_R0_C_CAC_240116 06 - 7100 Alum SH Fin.pdf Quality Assurance Contract Expiration Date 11/06/2028 Installation Instructions FL46524_R0_II_240116 06 - 7100 Alum SH Fin.pdf Verified By: Thomas J. Sotos, P.E. 55225 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: |
|
46524.4 |
7100 Impact, Flange Frame Single Hung Window |
7100 Impact, Flange Frame Single Hung Window |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +80/-80 Other: Please refer to the NOA for all other limitations. |
Certification Agency Certificate FL46524_R0_C_CAC_240116 05 - 7100 Alum SH Fl.pdf Quality Assurance Contract Expiration Date 12/27/2026 Installation Instructions FL46524_R0_II_240116 05 - 7100 Alum SH Fl.pdf Verified By: Thomas J. Sotos, P.E. 55225 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: |