| 46539.1 |
Classic Rib |
Min. 29 ga., 36" wide through fastened wall panel over min. 7/16” thick OSB deck or min. 15/32” thick plywood deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-135.0 Other: Outward load of 135 psf at fastener spacing of 6" o.c. |
Installation Instructions FL46539_R1_II_EvaluationReportC3062_1.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL46539_R1_AE_EvaluationReportC3062_1.pdf Created by Independent Third Party: Yes |
|
|
| 46539.2 |
Pro-Panel II |
Min. 29 ga., 36" wide through fastened wall panel over min. 15/32” thick plywood deck. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-71.5 Other: Outward load of 71.5 psf at fastener spacing of 12" o.c. |
Installation Instructions FL46539_R1_II_EvaluationReportC3062_2.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL46539_R1_AE_EvaluationReportC3062_2.pdf Created by Independent Third Party: Yes |
|
|
| 46539.3 |
R-Panel or PBR-Panel |
Min. 26 ga., 36" wide through fastened wall panel over min. 15/32” thick plywood deck. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-131.0 Other: Outward load of 131.0 psf at fastener spacing of 6" o.c. |
Installation Instructions FL46539_R1_II_EvaluationReportC3062_3.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL46539_R1_AE_EvaluationReportC3062_3.pdf Created by Independent Third Party: Yes |