| 13777.1 |
13.25" Ludowici Spanish, 18.375" Ludowici Spanish |
High profile, interlocking, one piece, 'S' Shaped |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13777_R7_II_23012510 Spanish Clay Roof Tile.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL13777_R7_AE_23012510 Spanish Clay Roof Tile.pdf |
|
|
| 13777.2 |
Americana 14", Classic 14", Williamsburg 14, Lanai 14", Norman, Calais, Provincial, Georgian, Colonial, Brittany, Antique, Crude, Flat Slab |
Flat Interlocking and Flat |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13777_R7_II_23012507 Morando14.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL13777_R7_AE_23012507 Morando14.pdf |
|
|
| 13777.3 |
Century Shake |
Flat Interlocking |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13777_R7_II_FL13777_R6_II_25091708 Century Shake.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL13777_R7_AE_FL13777_R6_II_25091708 Century Shake.pdf |
|
|
| 13777.4 |
Classic 16", Americana 16", Lanai 16", Williamsburg 16", LudoSlate, LudoShake |
Flat Interlocking |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13777_R7_II_23012511 Morando 16.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL13777_R7_AE_23012511 Morando 16.pdf |
|
|
| 13777.5 |
Creaton Visio Roof Tile |
Flat Interlocking |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13777_R7_II_FL13777-R5 COI 24092606 Creaton Visio.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL13777_R7_AE_FL13777-R5 COI 24092606 Creaton Visio.pdf |
|
|
| 13777.6 |
French |
Flat Interlocking |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13777_R7_II_23012509 French Clay Roof Tile.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL13777_R7_AE_23012509 French Clay Roof Tile.pdf |
|
|
| 13777.7 |
Languedocienne |
High Profile, two piece |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13777_R7_II_23012506 Lanquedocienne Clay Roof Tile.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL13777_R7_AE_23012506 Lanquedocienne Clay Roof Tile.pdf |
|
|
| 13777.8 |
Straight Barrel Mission 14.25",Straight Barrel Mission 16",Straight Barrel Mission 18", Palm Beach Tapered Mission, Cubana Mission, 16" Tappered Mission |
High profile, two piece |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL13777_R7_II_23012508 Straight, Palm Beach Tapered, Cubana and Tapered Mission.pdf Verified By: Miami-Dade BCCO - EVL Created by Independent Third Party: Evaluation Reports FL13777_R7_AE_23012508 Straight, Palm Beach Tapered, Cubana and Tapered Mission.pdf |