| 21367.1 |
1" Snap Lock Panel |
1-inch snap lock standing seam; Maximum 16-inch coverage; Optional intermediate ribs |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-112.5 Other: See evaluation report for limits of use. |
Installation Instructions FL21367_R7_II_AMF16004.7b 2026 FBC Eval 1in. Snap Lock final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL21367_R7_AE_AMF16004.7b 2026 FBC Eval 1in. Snap Lock final.pdf Created by Independent Third Party: Yes |
|
|
| 21367.2 |
1.5" Snap Lock Panel |
1.5-inch snap lock standing seam; Maximum 16-inch coverage; Optional intermediate ribs |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-56 Other: See evaluation report for limits of use. |
Installation Instructions FL21367_R7_II_AMF16004.7e 2026 FBC Eval 1.5in. Snap Lock final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL21367_R7_AE_AMF16004.7e 2026 FBC Eval 1.5in. Snap Lock final.pdf Created by Independent Third Party: Yes |
|
|
| 21367.3 |
5V Crimp Panel |
Preformed panel; 3/8-inch rib; Maximum 24-inch coverage |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-112.5 Other: See evaluation report for limits of use. |
Installation Instructions FL21367_R7_II_AMF16004.7d 2026 FBC Eval 5V Crimp final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL21367_R7_AE_AMF16004.7d 2026 FBC Eval 5V Crimp final.pdf Created by Independent Third Party: Yes |
|
|
| 21367.4 |
Standing Seam Panel |
1.5-inch standing seam panel; 180° lock; Maximum 16-inch coverage; Optional intermediate ribs |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-165 Other: See evaluation report for limits of use. |
Installation Instructions FL21367_R7_II_AMF16004.7c 2026 FBC Eval Standing Seam final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL21367_R7_AE_AMF16004.7c 2026 FBC Eval Standing Seam final.pdf Created by Independent Third Party: Yes |
|
|
| 21367.5 |
U Panel |
7/8-inch U panel and batten; Maximum 16-inch coverage; Optional intermediate ribs |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-52.5 Other: See evaluation report for limits of use. |
Installation Instructions FL21367_R7_II_AMF16004.7a 2026 FBC Eval U Panel final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL21367_R7_AE_AMF16004.7a 2026 FBC Eval U Panel final.pdf Created by Independent Third Party: Yes |