| 32108.1 |
Pella Entry Doors non-impact in-swing fiberglass panel & composite frame doors. |
105" x 81.63" OXXO door unit with opaque panels, glazed sidelights, & latch & deadbolt lock |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +45/-45 Other: Glass shall conform to the current ASTM E1300 standard and shall be safety glazed when required by FBC. See the uploaded configuration sheet here-in for all applicable door configurations & their maximum sizes. These doors have a 0 psf water rating. Therefore, door job site conditions must meet FBC requirements for doors without a water resistance rating. |
Certification Agency Certificate FL32108_R4_C_CAC_In-swing door configurtion table-Florida.pdf FL32108_R4_C_CAC_NI014746.10-R1.pdf Quality Assurance Contract Expiration Date 01/31/2034 Installation Instructions FL32108_R4_II_Anchor requirements in saltwater coastline areas.pdf FL32108_R4_II_Drawing 1975 digitally sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL32108_R4_AE_Drawing 1975 digitally sealed.pdf Created by Independent Third Party: Yes |
|
|
| 32108.2 |
Pella Entry Doors non-impact in-swing fiberglass panel & composite frame doors. |
105" x 81.63" OXXO door unit with opaque panels, glazed sidelights, & multipoint lock |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +45/-45 Other: Glass shall conform to the current ASTM E1300 standard and shall be safety glazed when required by FBC. See the uploaded configuration sheet here-in for all applicable door configurations & their maximum sizes. These doors have a 0 psf water rating. Therefore, door job site conditions must meet FBC requirements for doors without a water resistance rating. |
Certification Agency Certificate FL32108_R4_C_CAC_In-swing door configurtion table-Florida.pdf FL32108_R4_C_CAC_NI014746.02-R1.pdf Quality Assurance Contract Expiration Date 01/31/2034 Installation Instructions FL32108_R4_II_Anchor requirements in saltwater coastline areas.pdf FL32108_R4_II_Drawing 1975 digitally sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL32108_R4_AE_Drawing 1975 digitally sealed.pdf Created by Independent Third Party: Yes |
|
|
| 32108.3 |
Pella Entry Doors non-impact in-swing fiberglass panel & composite frame doors. |
105" x 81.63" OXXO door unit with glazed panels, glazed sidelights, & latch & deadbolt lock |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: Glass shall conform to the current ASTM E1300 standard and shall be safety glazed when required by FBC. See the uploaded configuration sheet here-in for all applicable door configurations & their maximum sizes. These doors have a 0 psf water rating. Therefore, door job site conditions must meet FBC requirements for doors without a water resistance rating. |
Certification Agency Certificate FL32108_R4_C_CAC_In-swing door configurtion table-Florida.pdf FL32108_R4_C_CAC_NI014746.01-R1.pdf Quality Assurance Contract Expiration Date 01/31/2034 Installation Instructions FL32108_R4_II_Anchor requirements in saltwater coastline areas.pdf FL32108_R4_II_Drawing 1975 digitally sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL32108_R4_AE_Drawing 1975 digitally sealed.pdf Created by Independent Third Party: Yes |
|
|
| 32108.4 |
Pella Entry Doors non-impact in-swing fiberglass panel & composite frame doors. |
105" x 81.63" OXXO door unit with glazed panels, glazed sidelights, & multipoint lock |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: Glass shall conform to the current ASTM E1300 standard and shall be safety glazed when required by FBC. See the uploaded configuration sheet here-in for all applicable door configurations & their maximum sizes. These doors have a 0 psf water rating. Therefore, door job site conditions must meet FBC requirements for doors without a water resistance rating. |
Certification Agency Certificate FL32108_R4_C_CAC_In-swing door configurtion table-Florida.pdf FL32108_R4_C_CAC_NI014746.06-R1.pdf Quality Assurance Contract Expiration Date 01/31/2034 Installation Instructions FL32108_R4_II_Anchor requirements in saltwater coastline areas.pdf FL32108_R4_II_Drawing 1975 digitally sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL32108_R4_AE_Drawing 1975 digitally sealed.pdf Created by Independent Third Party: Yes |
|
|
| 32108.5 |
Pella Entry Doors non-impact in-swing fiberglass panel & composite frame doors. |
105" x 81.63" OXXO door unit with flush glazed panels, flush glazed sidelights, & latch & deadbolt lock |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +45/-45 Other: Glass shall conform to the current ASTM E1300 standard and shall be safety glazed when required by FBC. See the uploaded configuration sheet here-in for all applicable door configurations & their maximum sizes. These doors have a 0 psf water rating. Therefore, door job site conditions must meet FBC requirements for doors without a water resistance rating. |
Certification Agency Certificate FL32108_R4_C_CAC_In-swing door configurtion table-Florida.pdf FL32108_R4_C_CAC_NI014746.07-R1.pdf Quality Assurance Contract Expiration Date 01/31/2034 Installation Instructions FL32108_R4_II_Anchor requirements in saltwater coastline areas.pdf FL32108_R4_II_Drawing 1975 digitally sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL32108_R4_AE_Drawing 1975 digitally sealed.pdf Created by Independent Third Party: Yes |
|
|
| 32108.6 |
Pella Entry Doors non-impact in-swing fiberglass panel & composite frame doors. |
105" x 81.63" OXXO door unit with flush glazed panels, flush glazed sidelights, & multipoint lock |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +45/-45 Other: Glass shall conform to the current ASTM E1300 standard and shall be safety glazed when required by FBC. See the uploaded configuration sheet here-in for all applicable door configurations & their maximum sizes. These doors have a 0 psf water rating. Therefore, door job site conditions must meet FBC requirements for doors without a water resistance rating. |
Certification Agency Certificate FL32108_R4_C_CAC_In-swing door configurtion table-Florida.pdf FL32108_R4_C_CAC_NI014746.08-R1.pdf Quality Assurance Contract Expiration Date 01/31/2034 Installation Instructions FL32108_R4_II_Anchor requirements in saltwater coastline areas.pdf FL32108_R4_II_Drawing 1975 digitally sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL32108_R4_AE_Drawing 1975 digitally sealed.pdf Created by Independent Third Party: Yes |
|
|
| 32108.7 |
Pella Entry Doors non-impact in-swing fiberglass panel & composite frame doors. |
105" x 97.63" OXXO door unit with opaque panels, glazed sidelights, & latch & deadbolt lock |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Glass shall conform to the current ASTM E1300 standard and shall be safety glazed when required by FBC. See the uploaded configuration sheet here-in for all applicable door configurations & their maximum sizes. These doors have a 0 psf water rating. Therefore, door job site conditions must meet FBC requirements for doors without a water resistance rating. |
Certification Agency Certificate FL32108_R4_C_CAC_In-swing door configurtion table-Florida.pdf FL32108_R4_C_CAC_NI014746.11-R2.pdf Quality Assurance Contract Expiration Date 01/31/2034 Installation Instructions FL32108_R4_II_Anchor requirements in saltwater coastline areas.pdf FL32108_R4_II_Drawing 1975 digitally sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL32108_R4_AE_Drawing 1975 digitally sealed.pdf Created by Independent Third Party: Yes |
|
|
| 32108.8 |
Pella Entry Doors non-impact in-swing fiberglass panel & composite frame doors. |
105" x 97.63" OXXO door unit with opaque panels, glazed sidelights, & multipoint lock |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Glass shall conform to the current ASTM E1300 standard and shall be safety glazed when required by FBC. See the uploaded configuration sheet here-in for all applicable door configurations & their maximum sizes. These doors have a 0 psf water rating. Therefore, door job site conditions must meet FBC requirements for doors without a water resistance rating. |
Certification Agency Certificate FL32108_R4_C_CAC_In-swing door configurtion table-Florida.pdf FL32108_R4_C_CAC_NI014746.03-R2.pdf Quality Assurance Contract Expiration Date 01/31/2034 Installation Instructions FL32108_R4_II_Anchor requirements in saltwater coastline areas.pdf FL32108_R4_II_Drawing 1975 digitally sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL32108_R4_AE_Drawing 1975 digitally sealed.pdf Created by Independent Third Party: Yes |
|
|
| 32108.9 |
Pella Entry Doors non-impact in-swing fiberglass panel & composite frame doors. |
105" x 97.63" OXXO door unit with glazed panels, glazed sidelights, & latch & deadbolt lock |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: Glass shall conform to the current ASTM E1300 standard and shall be safety glazed when required by FBC. See the uploaded configuration sheet here-in for all applicable door configurations & their maximum sizes. These doors have a 0 psf water rating. Therefore, door job site conditions must meet FBC requirements for doors without a water resistance rating. |
Certification Agency Certificate FL32108_R4_C_CAC_In-swing door configurtion table-Florida.pdf FL32108_R4_C_CAC_NI014746.09-R2.pdf Quality Assurance Contract Expiration Date 01/31/2034 Installation Instructions FL32108_R4_II_Anchor requirements in saltwater coastline areas.pdf FL32108_R4_II_Drawing 1975 digitally sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL32108_R4_AE_Drawing 1975 digitally sealed.pdf Created by Independent Third Party: Yes |
|
|
| 32108.10 |
Pella Entry Doors non-impact in-swing fiberglass panel & composite frame doors. |
105" x 97.63" OXXO door unit with glazed panels, glazed sidelights, & multipoint lock |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: Glass shall conform to the current ASTM E1300 standard and shall be safety glazed when required by FBC. See the uploaded configuration sheet here-in for all applicable door configurations & their maximum sizes. These doors have a 0 psf water rating. Therefore, door job site conditions must meet FBC requirements for doors without a water resistance rating. |
Certification Agency Certificate FL32108_R4_C_CAC_In-swing door configurtion table-Florida.pdf FL32108_R4_C_CAC_NI014746.05-R2.pdf Quality Assurance Contract Expiration Date 01/31/2034 Installation Instructions FL32108_R4_II_Anchor requirements in saltwater coastline areas.pdf FL32108_R4_II_Drawing 1975 digitally sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL32108_R4_AE_Drawing 1975 digitally sealed.pdf Created by Independent Third Party: Yes |
|
|
| 32108.11 |
Pella Entry Doors non-impact in-swing fiberglass panel & composite frame doors. |
105" x 97.63" OXXO door unit with flush glazed panels, flush glazed sidelights, & latch & deadbolt lock |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-40 Other: Glass shall conform to the current ASTM E1300 standard and shall be safety glazed when required by FBC. See the uploaded configuration sheet here-in for all applicable door configurations & their maximum sizes. These doors have a 0 psf water rating. Therefore, door job site conditions must meet FBC requirements for doors without a water resistance rating. |
Certification Agency Certificate FL32108_R4_C_CAC_In-swing door configurtion table-Florida.pdf FL32108_R4_C_CAC_NI014746-R2.pdf Quality Assurance Contract Expiration Date 01/31/2034 Installation Instructions FL32108_R4_II_Anchor requirements in saltwater coastline areas.pdf FL32108_R4_II_Drawing 1975 digitally sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL32108_R4_AE_Drawing 1975 digitally sealed.pdf Created by Independent Third Party: Yes |
|
|
| 32108.12 |
Pella Entry Doors non-impact in-swing fiberglass panel & composite frame doors. |
105" x 97.63" OXXO door unit with flush glazed panels, flush glazed sidelights, & multipoint lock |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-40 Other: Glass shall conform to the current ASTM E1300 standard and shall be safety glazed when required by FBC. See the uploaded configuration sheet here-in for all applicable door configurations & their maximum sizes. These doors have a 0 psf water rating. Therefore, door job site conditions must meet FBC requirements for doors without a water resistance rating. |
Certification Agency Certificate FL32108_R4_C_CAC_In-swing door configurtion table-Florida.pdf FL32108_R4_C_CAC_NI014746.04-R2.pdf Quality Assurance Contract Expiration Date 01/31/2034 Installation Instructions FL32108_R4_II_Anchor requirements in saltwater coastline areas.pdf FL32108_R4_II_Drawing 1975 digitally sealed.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL32108_R4_AE_Drawing 1975 digitally sealed.pdf Created by Independent Third Party: Yes |