| 17535.1 |
Amarr Carriage Court (Model 1480) |
IRC-1418-130-26 Thru 18'-2 wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25.1/-28.4 Other: Glazing not available in wind borne debris regions; optional composite overlay |
Installation Instructions FL17535_R4_II_IRC-1418-130-26 Drawing 7-16 FL.pdf Verified By: Thomas L. Shelmerdine PE-0048579 Created by Independent Third Party: Yes Evaluation Reports FL17535_R4_AE_IRC-1418-130-26 Evaluation Report 7-16 FL.pdf FL17535_R4_AE_IRC-1418-130-26 Report 7-16 FL.pdf Created by Independent Third Party: Yes |
|
|
| 17535.2 |
Amarr Carriage Court (Model 1480) |
IRC-1409-130-15-I Thru 9'-2 wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +26.4/-31.1 Other: Optional composite overlay |
Installation Instructions FL17535_R4_II_IRC-1409-130-15-I Drawing 7-16 FL.pdf Verified By: Thomas L. Shelmerdine PE-0048579 Created by Independent Third Party: Yes Evaluation Reports FL17535_R4_AE_IRC-1409-130-15-I Evaluation Report 7-16 FL.pdf FL17535_R4_AE_IRC-1409-130-15-I Report 7-16 FL.pdf Created by Independent Third Party: Yes |
|
|
| 17535.3 |
Amarr Carriage Court (Model 1480) |
IRC-1418-130-26-I Thru 18'-2 wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +25.1/-28.4 Other: Optional composite overlay |
Installation Instructions FL17535_R4_II_IRC-1418-130-26-I Drawing 7-16 FL.pdf Verified By: Thomas L. Shelmerdine PE-0048579 Created by Independent Third Party: Yes Evaluation Reports FL17535_R4_AE_IRC-1418-130-26-I Evaluation Report 7-16 FL.pdf FL17535_R4_AE_IRC-1418-130-26-I Report 7-16 FL.pdf Created by Independent Third Party: Yes |
|
|
| 17535.4 |
Model 1350 (Amarr 2741);Model 2700 (Amarr 2742) |
IBC-1316-130-15 Thru 16'-2 wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +23.3/-26.3 Other: Glazing not available in wind borne debris regions |
Installation Instructions FL17535_R4_II_IBC-1316-130-15 Drawing 7-16 FL.pdf Verified By: Thomas L. Shelmerdine PE-0048579 Created by Independent Third Party: Yes Evaluation Reports FL17535_R4_AE_IBC-1316-130-15 Evaluation Report 7-16 FL.pdf FL17535_R4_AE_IBC-1316-130-15 Report 7-16 FL.pdf Created by Independent Third Party: Yes |
|
|
| 17535.5 |
Model 1380 (Amarr 2731) |
IBC-1818-136-26-I Thru 18'-2 wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +25.1/-28.4 Other: |
Installation Instructions FL17535_R4_II_IBC-1818-136-26-I Drawing 7-16 FL.pdf Verified By: Thomas L. Shelmerdine PE-0048579 Created by Independent Third Party: Yes Evaluation Reports FL17535_R4_AE_IBC-1818-136-26-I Evaluation Report 7-16 FL.pdf FL17535_R4_AE_IBC-1818-136-26-I Report 7-16 FL.pdf Created by Independent Third Party: Yes |
|
|
| 17535.6 |
Model 1380 (Amarr 2731) |
IBC-1809-136-15-I Thru 9'-2 wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +26.4/-31.1 Other: |
Installation Instructions FL17535_R4_II_IBC-1809-136-15-I Drawing 7-16 FL.pdf Verified By: Thomas L. Shelmerdine PE-0048579 Created by Independent Third Party: Yes Evaluation Reports FL17535_R4_AE_IBC-1809-136-15-I Evaluation Report 7-16 FL.pdf FL17535_R4_AE_IBC-1809-136-15-I Report 7-16 FL.pdf Created by Independent Third Party: Yes |
|
|
| 17535.7 |
Model 1380 (Amarr 2731) |
IBC-1818-136-26 Thru 18'-2 wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25.1/-28.4 Other: Glazing not available in wind borne debris regions |
Installation Instructions FL17535_R4_II_IBC-1818-136-26 Drawing 7-16 FL.pdf Verified By: Thomas L. Shelmerdine PE-0048579 Created by Independent Third Party: Yes Evaluation Reports FL17535_R4_AE_IBC-1818-136-26 Evaluation Report 7-16 FL.pdf FL17535_R4_AE_IBC-1818-136-26 Report 7-16 FL.pdf Created by Independent Third Party: Yes |
|
|
| 17535.8 |
Model 2000 (Amarr 2002, 2012, 2022);Model 2400 (Amarr 2402, 2412, 2422) |
IBC-2410-145-15 Thru 10'-2 wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30.0/-34.9 Other: Glazing not available in wind borne debris regions |
Installation Instructions FL17535_R4_II_IBC-2410-145-15 Drawing 7-16 FL.pdf Verified By: Thomas L. Shelmerdine PE-0048579 Created by Independent Third Party: Yes Evaluation Reports FL17535_R4_AE_IBC-2410-145-15 Evaluation Report 7-16 FL.pdf FL17535_R4_AE_IBC-2410-145-15 Report 7-16 FL.pdf Created by Independent Third Party: Yes |
|
|
| 17535.9 |
Model 2000 (Amarr 2002, 2012, 2022);Model 2400 (Amarr 2402, 2412, 2422) |
IBC-2414-145-24 Thru 14'-2 wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +29.2/-33.3 Other: Glazing not available in wind borne debris regions |
Installation Instructions FL17535_R4_II_IBC-2414-145-24 Drawing 7-16 FL.pdf Verified By: Thomas L. Shelmerdine PE-0048579 Created by Independent Third Party: Yes Evaluation Reports FL17535_R4_AE_IBC-2414-145-24 Evaluation Report 7-16 FL.pdf FL17535_R4_AE_IBC-2414-145-24 Report 7-16 FL.pdf Created by Independent Third Party: Yes |
|
|
| 17535.10 |
Model 2000 (Amarr 2002, 2012, 2022);Model 2400 (Amarr 2402, 2412, 2422);Model 2500 (Amarr 2502, 2512) |
IBC-2509-130-15 Thru 9'-2 wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +24.3/-28.4 Other: Glazing not available in wind borne debris regions |
Installation Instructions FL17535_R4_II_IBC-2509-130-15 Drawing 7-16 FL.pdf Verified By: Thomas L. Shelmerdine PE-0048579 Created by Independent Third Party: Yes Evaluation Reports FL17535_R4_AE_IBC-2509-130-15 Evaluation Report 7-16 FL.pdf FL17535_R4_AE_IBC-2509-130-15 Report 7-16 FL.pdf Created by Independent Third Party: Yes |
|
|
| 17535.11 |
Model 2000 (Amarr 2002, 2012, 2022);Model 2400 (Amarr 2402, 2412, 2422);Model 2500 (Amarr 2502, 2512) |
IBC-2516-130-24 Thru 16'-2 wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +23.3/-26.3 Other: Glazing not available in wind borne debris regions |
Installation Instructions FL17535_R4_II_IBC-2516-130-24 Drawing 7-16 FL.pdf Verified By: Thomas L. Shelmerdine PE-0048579 Created by Independent Third Party: Yes Evaluation Reports FL17535_R4_AE_IBC-2516-130-24 Evaluation Report 7-16 FL.pdf FL17535_R4_AE_IBC-2516-130-24 Report 7-16 FL.pdf Created by Independent Third Party: Yes |