| 17506.1 |
Clad Energy Saver Casement Mulled |
Clad Energy Saver 2-Wide Casement Operator (57"x96") |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25/-25 Other: Maximum individual frame size of 57"x96" (1435mmx2445mm); CCL #436-H-105.41; Expiration date 9-15-24. Glass make-up consists of two 5.7mm annealed lites of glass; complies with ASTM E1300 requirements. |
Certification Agency Certificate FL17506_R2_C_CAC_436-H-105-41 2-WIDE OP CLAD CA.pdf Quality Assurance Contract Expiration Date 09/15/2024 Installation Instructions FL17506_R2_II_Clad CA OP 2W 57x96 CCL 436-H-105-41 Test ESP017804P-1612.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17506.2 |
Clad Energy Saver Springline Casement Operator |
Clad Energy Saver Springline Casement Operator 36"x72" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +45/-45 Other: Maximum individual frame size of 36"x72" (919mmx1834mm); CCL #436-H-105.42; Expiration date 12-15-2024. Glass make-up consists of two 3.9mm annealed lites of glass; complies with ASTM E1300 requirements. |
Certification Agency Certificate FL17506_R2_C_CAC_436-H-105-42 SPRNGLINE OP CLAD CA.pdf Quality Assurance Contract Expiration Date 12/15/2024 Installation Instructions FL17506_R2_II_Clad ES SpringLine CA OP 36x72 CCL 436-H-105-42 ESP018511P-1656.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |