| 389.1 |
Bertha HV Accordion Shutter-Blade 1 Only- (Non-HVHZ)- Drwg 26-103 |
Extruded aluminum interlocking blades retained by tracks (top and bottom) for storm protection |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large missile level “D”. Max. Span is 16’-0” for 30 p.s.f negative ASD load depending on centermates and locking rod configuration for the HV1 blade, 8’-0” for +64, -72 p.s.f. A.S.D. load for HV blade for Keystone mountings 7’-0” p.s.f. for metals stud mountings and 8'-0" for 110 p.s.f. for HV1A working in unison. See sheets 7, 11 and 20 respectively of installation drawings for other spans and pressures. |
Installation Instructions FL389_R12_II_Drawing 26-103.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL389_R12_AE_PE Report Drawing 26-103.pdf Created by Independent Third Party: Yes |
|
|
| 389.2 |
Bertha HV Accordion Shutter-COMBO- (Non-HVHZ)- Drwg 26-104 |
Extruded aluminum interlocking blades retained by tracks (top and bottom) for storm protection |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large missile. Max. 16’-0” span at 30 p.s.f ASD load for Blade 1 and 18’-0” for Blade 2. See schedules on sheet 12, 25 and 28 respectively |
Installation Instructions FL389_R12_II_Drawing 26-104 REVISED.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL389_R12_AE_PE Report Drawing 26-104 REVISED.pdf Created by Independent Third Party: Yes |