FL # FL389-R11
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer American Shutter Systems Association, Inc.
Address/Phone/Email 4268 Westroads Drive
West Palm Beach, FL 33407
(561) 209-8263
bfeeley@easternmetal.com
 
Authorized Signature Bill Feeley
lrodriguez@easternmetal.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Shutters
Subcategory Accordion
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Walter A.. Tillit, Jr. P.E.
Florida License PE-44167
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2027
Validated By John Henry Kampmann Jr.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL389_R11_COI_Certification of Independence Drawing 23-126.pdf
FL389_R11_COI_CERTIFICATION OF INDEPENDENCE DRAWING 23-127.pdf
FL389_R11_COI_Certification of Independence Drawing 23-133.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E-18862012
ASTM E-19962012
ASTM E-3302002
TAS 201, 202, 2031994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL389_R11_Equiv_Letter 23-450.pdf
 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 10/14/2023
Date Validated 10/17/2023
Date Pending FBC Approval 10/22/2023
Date Approved 12/12/2023
Date Revised 08/16/2026
 
Summary of Products
FL # Model, Number or Name Description
389.1 Bertha HV Accordion Shutter - Blade 3 - (Non-HVHZ) - Drwg 23-133 Extruded aluminum interlocking blades retained by tracks (top and bottom) for storm protection
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: Large Missile Level "D".Max span is 12’-3” for 40 psf positive ASD load and 13’-0” for 35 psf negative ASD load the HV3 blade w/o window blade,5’-2” for 110 psf ASD load for HV3 blade w/o window blade and 8’-11” for 62 psf, 9’-11” for 55 psf HV3 blade w/window blade working in unison.Max.span for HV3 blade w/o window blade for installations into Metal Stud walls is 79” for max. ASD pressure rating of +72,-72 and 84” for +64,-64 psf. See sheet 5 for other spans and ASD pressures.
Installation Instructions
 FL389_R11_II_Drawing 23-133.pdf
 Verified By: American Test Lab of South Florida, Inc.
 Created by Independent Third Party: Yes
Evaluation Reports
 FL389_R11_AE_Product Evaluation Report Drawing 23-133.pdf
 Created by Independent Third Party: Yes
389.2 Bertha HV Accordion Shutter-Blade 1 Only- (Non-HVHZ)- Drwg 23-127 Extruded aluminum interlocking blades retained by tracks (top and bottom) for storm protection
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: Large missile level “D”. Max. Span is 16’-0” for 30 p.s.f negative ASD load depending on centermates and locking rod configuration for the HV1 blade, 8’-0” for +64, -72 p.s.f. A.S.D. load for HV blade for Keystone mountings 7’-0” p.s.f. for metals stud mountings and 8'-0" for 110 p.s.f. for HV1A working in unison. See sheets 7, 11 and 20 respectively of installation drawings for other spans and pressures.
Installation Instructions
 FL389_R11_II_DRAWING 23-127.pdf
 Verified By: American Test Lab of South Florida, Inc.
 Created by Independent Third Party: Yes
Evaluation Reports
 FL389_R11_AE_PRODUCT EVALUATION REPORT DRAWING 23-127.pdf
 Created by Independent Third Party: Yes
389.3 Bertha HV Accordion Shutter-COMBO- (Non-HVHZ)- Drwg 23-126 Extruded aluminum interlocking blades retained by tracks (top and bottom) for storm protection
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: Large missile. Max. 16’-0” span at 30 p.s.f ASD load for Blade 1 and 18’-0” for Blade 2. See schedules on sheet 12, 25 and 28 respectively
Installation Instructions
 FL389_R11_II_Drawing 23-126.pdf
 Verified By: American Test Lab of South Florida, Inc.
 Created by Independent Third Party: Yes
Evaluation Reports
 FL389_R11_AE_Product Evaluation Report Drawing 23-126.pdf
 Created by Independent Third Party: Yes
 