Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL41978-R7
Application Type Revision
Code Version 2026
Application Status Applied For
 
Comments
Archived
 
Product Manufacturer VPI Windows
Address/Phone/Email 3420 E. Ferry
Spokane, WA 99202
(541) 850-2650
fbc1@jeldwen.com
 
Authorized Signature Rylee Fricks
fbc1@jeldwen.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Windows
Subcategory Single Hung
 
Compliance Method Certification Mark or Listing
 
Certification Agency Fenestration and Glazing Industry Alliance (formerly AAMA)
Validated By Fenestration and Glazing Industry Alliance (formerly AAMA)
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA 101/I.S.2/A4402017
AAMA/WDMA/CSA 101/I.S.2/A4402011
AAMA/WDMA/CSA 101/I.S.2/A4402022
 
Equivalence of Product Standards
Certified By

Approved Certification Agency
FL41978_R7_Equiv_NAFS 11 -17 - 22 Equivalency.pdf
 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 08/06/2026
Date Validated
 
Summary of Products
FL # Model, Number or Name Description
41978.1 Endurance 591 Single Hung (O/X.O/X) 72" x 60"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. 
Certification Agency Certificate
 FL41978_R7_C_CAC_VPI Windows - Endurance 591 SH Twin (2) July 2026 (ext.5).pdf
Quality Assurance Contract Expiration Date
 01/26/2032
Installation Instructions
 FL41978_R7_II_ID 355 Endurance SH-SH Non-Impact Installations FBC Rev.2.pdf
 Verified By: Michael D. Stremmel 65868
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41978_R7_AE_25164-1 VPI Quality Windows - Twin SH FBC.pdf
 FL41978_R7_AE_25164-2 VPI Quality Windows - Twin SH FBC.pdf
 Created by Independent Third Party: Yes
41978.2 Endurance 591 Single Hung (O/X) 56" x 96"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +30/-30
 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. 
Certification Agency Certificate
 FL41978_R7_C_CAC_VPI Windows - Endurance 591 SH (4) July 2026 (ext.5).pdf
Quality Assurance Contract Expiration Date
 01/26/2032
Installation Instructions
 FL41978_R7_II_ID_40_SH R1 DSS.pdf
 Verified By: Micah Swartz 93579
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41978_R7_AE_MS 24-06007 Calcs R1 DSS.pdf
 Created by Independent Third Party: Yes
41978.3 Endurance 591 Single Hung (O/X.O/X) 88" x 96"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +45/-45
 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. 
Certification Agency Certificate
 FL41978_R7_C_CAC_VPI_E180925_Endurance_591_SH_Twin_(1)_(ext.5)_I2449.01-901-44.pdf
Quality Assurance Contract Expiration Date
 04/17/2028
Installation Instructions
 FL41978_R7_II_ID_176_SH-SH R1 DSS.pdf
 Verified By: Micah Swartz 93579
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41978_R7_AE_MS 24-06009 Calcs R1 - ID_176__SH-SH DSS.pdf
 Created by Independent Third Party: Yes
41978.4 Endurance 591 Single Hung (O/X.O/X) 144" x 96"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +30/-30
 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. 
Certification Agency Certificate
 FL41978_R7_C_CAC_VPI_E180504_Endurance_591_SH_Triple_(1)_(ext.5)_I0004.01-901-44.pdf
Quality Assurance Contract Expiration Date
 02/28/2028
Installation Instructions
 FL41978_R7_II_ID_184_SH-SH-SH R1 DSS.pdf
 Verified By: Micah Swartz 93579
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41978_R7_AE_MS 24-06010 Calcs R1 DSS.pdf
 Created by Independent Third Party: Yes
41978.5 Endurance 591 Single Hung (O/X/O) 60" x 144"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +40/-40
 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. 
Certification Agency Certificate
 FL41978_R7_C_CAC_VPI_E190312_ Endurance_SH_over_Fixed_(2)_(ext.5)_J3052.01-901-44.pdf
Quality Assurance Contract Expiration Date
 02/11/2029
Installation Instructions
 FL41978_R7_II_ID_182_SH-A R1 DSS.pdf
 Verified By: Micah Swartz 93573
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41978_R7_AE_MS 24-10009 Calcs R1 DSS.pdf
 Created by Independent Third Party: Yes
41978.6 Endurance 591 Single Hung (O/X.O) 96" x 96"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +30/-30
 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. 
Certification Agency Certificate
 FL41978_R7_C_CAC_VPI_E240322_Endurance_591_SH_Composite_(25)_R1378.01-901-44.pdf
Quality Assurance Contract Expiration Date
 02/28/2028
Installation Instructions
 FL41978_R7_II_ID_498_SH-PW R1 DSS.pdf
 Verified By: Micah Swartz 93573
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41978_R7_AE_MS 24-10008 Calcs R1 - ID_498_SH-PW DSS.pdf
 Created by Independent Third Party: Yes
41978.7 Endurance 591 Single Hung (O/X/O.O/X/O) 88" x 96"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +45/-45
 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. 
Certification Agency Certificate
 FL41978_R7_C_CAC_VPI_E180925_Endurance_591_SH_Composite_(10)_(ext.5)_I2450.01-901-44.pdf
Quality Assurance Contract Expiration Date
 02/22/2028
Installation Instructions
 FL41978_R7_II_ID_175_SH-SH-AT R1 DSS.pdf
 Verified By: Micah Swartz 93573
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41978_R7_AE_MS 24-10007 Calcs R1 - ID_175_SH-SH-AT DSS.pdf
 Created by Independent Third Party: Yes
41978.8 Endurance 591 Single Hung (O/X) 48" x 84"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +55/-55
 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. 
Certification Agency Certificate
 FL41978_R7_C_CAC_VPI-E160614_End_591_SH_(2)_(ext.5)_F9685.01-901-44 41978.8.pdf
Quality Assurance Contract Expiration Date
 06/14/2031
Installation Instructions
 FL41978_R7_II_ID_80_SH R1 DSS.pdf
 Verified By: Micah Swartz 93573
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41978_R7_AE_SCE 25-05007 R1 Calcs DSS ID_80_SH.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 