| 41973.1 |
Comfort Shield Sliding Window |
72" x 44" vinyl non-impact XO/OX sliding window with lock stile reinforcement |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: Configurations of glass shall conform to the current ASTM E1300 standard. |
Certification Agency Certificate FL41973_R4_C_CAC_Pella - 250-Power Symph-CWS-Comf. Shield HS (3) (Fin Finless) Mar. 2024 (ext.5).pdf Quality Assurance Contract Expiration Date 05/24/2027 Installation Instructions FL41973_R4_II_Drawing 2018 digitally-sealed.pdf Verified By: Warren W. Schaefer P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL41973_R4_AE_Drawing 2018 digitally-sealed.pdf Created by Independent Third Party: Yes |
|
|
| 41973.2 |
Comfort Shield Sliding Window |
72" x 44" vinyl non-impact XO/OX sliding window with lock and meeting stile reinforcements. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Other: Configurations of glass shall conform to the current ASTM E1300 standard. |
Certification Agency Certificate FL41973_R4_C_CAC_Pella - 250-Power Symph-CWS-Comf. Shield HS (5) (Fin Finless) June 2023 (ext.5).pdf Quality Assurance Contract Expiration Date 05/24/2027 Installation Instructions FL41973_R4_II_Drawing 2018 digitally-sealed.pdf Verified By: Warren W. Schaefer P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL41973_R4_AE_Drawing 2018 digitally-sealed.pdf Created by Independent Third Party: Yes |
|
|
| 41973.3 |
Comfort Shield Sliding Window |
108" x 44" 1/4 vent vinyl non-impact XOX sliding window with lock stile reinforcement. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: Other: Configurations of glass shall conform to the current ASTM E1300 standard. |
Certification Agency Certificate FL41973_R4_C_CAC_Pella - 250-Power Symph-CWS-Comf. Shield HS (7) (Fin Finless) June 2023 (ext.5).pdf Quality Assurance Contract Expiration Date 08/06/2027 Installation Instructions FL41973_R4_II_Drawing 2018 digitally-sealed.pdf Verified By: Warren W. Schaefer P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL41973_R4_AE_Drawing 2018 digitally-sealed.pdf Created by Independent Third Party: Yes |
|
|
| 41973.4 |
Comfort Shield Sliding Window |
108" x 44" 1/4 vent vinyl non-impact XOX sliding window with lock and meeting stile reinforcements. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Other: Configurations of glass shall conform to the current ASTM E1300 standard. |
Certification Agency Certificate FL41973_R4_C_CAC_Pella - 250-Power Symph-CWS-Comf. Shield HS (8) (Fin Finless) June 2023 (ext.5).pdf Quality Assurance Contract Expiration Date 08/06/2027 Installation Instructions FL41973_R4_II_Drawing 2018 digitally-sealed.pdf Verified By: Warren W. Schaefer P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL41973_R4_AE_Drawing 2018 digitally-sealed.pdf Created by Independent Third Party: Yes |
|
|
| 41973.5 |
Comfort Shield Sliding Window |
108" x 44" 1/3 vent vinyl non-impact XOX sliding window with lock stile reinforcement. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: Other: Configurations of glass shall conform to the current ASTM E1300 standard. |
Certification Agency Certificate FL41973_R4_C_CAC_Pella - 250-Power Symph-CWS-Comf. Shield HS (10) (Fin Finless) June 2023 (ext.5).pdf Quality Assurance Contract Expiration Date 08/06/2027 Installation Instructions FL41973_R4_II_Drawing 2018 digitally-sealed.pdf Verified By: Warren W. Schaefer P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL41973_R4_AE_Drawing 2018 digitally-sealed.pdf Created by Independent Third Party: Yes |
|
|
| 41973.6 |
Comfort Shield Sliding Window |
108" x 44" 1/3 vent vinyl non-impact XOX sliding window with lock and meeting stile reinforcements. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Configurations of glass shall conform to the current ASTM E1300 standard. |
Certification Agency Certificate FL41973_R4_C_CAC_Pella - 250-Power Symph-CWS-Comf. Shield HS (12) (Fin Finless) Mar. 2024 (ext.5).pdf Quality Assurance Contract Expiration Date 08/06/2027 Installation Instructions FL41973_R4_II_Drawing 2018 digitally-sealed.pdf Verified By: Warren W. Schaefer P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL41973_R4_AE_Drawing 2018 digitally-sealed.pdf Created by Independent Third Party: Yes |
|
|
| 41973.7 |
Comfort Shield Sliding Window |
52.25" x 62" vinyl non-impact XO/OX sliding window with lock and meeting stile reinforcements. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Other: Configurations of glass shall conform to the current ASTM E1300 standard. |
Certification Agency Certificate FL41973_R4_C_CAC_Pella - 250-Power Symph-CWS-Comf. Shield HS (15) (Fin Finless) June 2023 (ext.5).pdf Quality Assurance Contract Expiration Date 04/01/2028 Installation Instructions FL41973_R4_II_Drawing 2018 digitally-sealed.pdf Verified By: Warren W. Schaefer P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL41973_R4_AE_Drawing 2018 digitally-sealed.pdf Created by Independent Third Party: Yes |
|
|
| 41973.8 |
Comfort Shield Sliding Window |
96" x 62" Vinyl, Non-Impact, XO/OX, Sliding Window |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: Other: Configurations of glass shall conform to the current ASTM E1300 standard. |
Certification Agency Certificate FL41973_R4_C_CAC_20992 - Pella - AAMA APC.pdf Quality Assurance Contract Expiration Date 10/19/2030 Installation Instructions FL41973_R4_II_Drawing 2018 digitally-sealed.pdf Verified By: Warren W. Schaefer P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL41973_R4_AE_Drawing 2018 digitally-sealed.pdf Created by Independent Third Party: Yes |
|
|
| 41973.9 |
Comfort Shield Sliding Window |
78" x 84.5" overall size vinyl non-impact XO/OX sliding window with integral transom. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25/-25 Other: Other: Configurations of glass shall conform to the current ASTM E1300 standard. |
Certification Agency Certificate FL41973_R4_C_CAC_Pella - 250-Power Symph-CWS-Comf. Shield HS (13) (Fin) June 2023 (ext.5).pdf Quality Assurance Contract Expiration Date 08/29/2027 Installation Instructions FL41973_R4_II_Drawing 2018 digitally-sealed.pdf Verified By: Warren W. Schaefer P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL41973_R4_AE_Drawing 2018 digitally-sealed.pdf Created by Independent Third Party: Yes |
|
|
| 41973.10 |
Comfort Shield Sliding Window |
120" x 62" Vinyl, Non-Impact, XOX, 1/4 Vent, Sliding Window |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25/-25 Other: Other: Configurations of glass shall conform to the current ASTM E1300 standard. |
Certification Agency Certificate FL41973_R4_C_CAC_20991 - Pella - AAMA APC.pdf Quality Assurance Contract Expiration Date 10/15/2030 Installation Instructions FL41973_R4_II_Drawing 2018 digitally-sealed.pdf Verified By: Warren W. Schaefer P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL41973_R4_AE_Drawing 2018 digitally-sealed.pdf Created by Independent Third Party: Yes |
|
|
| 41973.11 |
Comfort Shield Sliding Window |
120" x 62" Vinyl, Non-Impact, XOX, 1/3 Vent, Sliding Window |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: Other: Configurations of glass shall conform to the current ASTM E1300 standard. |
Certification Agency Certificate FL41973_R4_C_CAC_20993 - Pella - AAMA APC.pdf Quality Assurance Contract Expiration Date 10/15/2030 Installation Instructions FL41973_R4_II_Drawing 2018 digitally-sealed.pdf Verified By: Warren W. Schaefer P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL41973_R4_AE_Drawing 2018 digitally-sealed.pdf Created by Independent Third Party: Yes |
|
|
| 41973.12 |
Comfort Shield Sliding Window |
96" x 72" Vinyl, Non-Impact, XOX, 1/4 Vent, Sliding Window |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25/-25 Other: Other: Configurations of glass shall conform to the current ASTM E1300 standard. |
Certification Agency Certificate FL41973_R4_C_CAC_20979 - Pella - AAMA APC.pdf Quality Assurance Contract Expiration Date 10/13/2030 Installation Instructions FL41973_R4_II_Drawing 2018 digitally-sealed.pdf Verified By: Warren W. Schaefer P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL41973_R4_AE_Drawing 2018 digitally-sealed.pdf Created by Independent Third Party: Yes |
|
|
| 41973.13 |
Comfort Shield Sliding Window |
96" x 72" Vinyl, Non-Impact, XOX, 1/3 Vent, Sliding Window |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25/-25 Other: Other: Configurations of glass shall conform to the current ASTM E1300 standard. |
Certification Agency Certificate FL41973_R4_C_CAC_20986 - Pella - AAMA APC.pdf Quality Assurance Contract Expiration Date 10/13/2030 Installation Instructions FL41973_R4_II_Drawing 2018 digitally-sealed.pdf Verified By: Warren W. Schaefer P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL41973_R4_AE_Drawing 2018 digitally-sealed.pdf Created by Independent Third Party: Yes |
|
|
| 41973.14 |
Comfort Shield Sliding Window |
73.5" x 72" Vinyl, Non-Impact, XO/OX, Sliding Window |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25/-25 Other: Other: Configurations of glass shall conform to the current ASTM E1300 standard. |
Certification Agency Certificate FL41973_R4_C_CAC_20996 - Pella - AAMA APC.pdf Quality Assurance Contract Expiration Date 10/19/2030 Installation Instructions FL41973_R4_II_Drawing 2018 digitally-sealed.pdf Verified By: Warren W. Schaefer P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL41973_R4_AE_Drawing 2018 digitally-sealed.pdf Created by Independent Third Party: Yes |