| 3900.1 |
SSFF1 |
Min 29 ga., max 24" wide concealed fastened roof panel over plywood deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5 Other: UL Construction No. 529. Design uplift pressure for Class 90 = 52.5 psf. The required design wind loads shall be determined for each project. The maximum fastener spacing listed herein shall not be exceeded. All rational analysis computations shall be prepared by a qualified design professional, as required by Florida Building Code. |
Certification Agency Certificate FL3900_R3_C_CAC_TGKX.529.pdf Quality Assurance Contract Expiration Date 12/31/2026 Installation Instructions FL3900_R3_II_TGKX.529.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 3900.2 |
Strongseam AG Panel |
Min 29 ga., max 36" wide through fastened panel over plywood deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5 Other: UL Construction No. 560. Design uplift pressure for Class 90 = 52.5 psf. The required design wind loads shall be determined for each project. The maximum fastener spacing listed herein shall not be exceeded. All rational analysis computations shall be prepared by a qualified design professional, as required by Florida Building Code. |
Certification Agency Certificate FL3900_R3_C_CAC_TGKX.560.pdf Quality Assurance Contract Expiration Date 12/31/2026 Installation Instructions FL3900_R3_II_TGKX.560.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |