| 39083.1 |
275 New Lock Panel |
Min. 24 ga., 17.75" wide standing seam roof panel over open supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-165 Other: Uplift load of -165 psf at clip spacing of 12" o.c. for 22 ga. panel |
Installation Instructions FL39083_R1_II_EvaluationReportC2703_1.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL39083_R1_AE_EvaluationReportC2703_1.pdf Created by Independent Third Party: Yes |
|
|
| 39083.2 |
Ag Panel |
Min. 29 ga., 36" wide, through fastened panel over open supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-113.8 Other: Uplift load of -113.8 psf at fastener spacing of 24" o.c. |
Installation Instructions FL39083_R1_II_EvaluationReportC2703_2.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL39083_R1_AE_EvaluationReportC2703_2.pdf Created by Independent Third Party: Yes |
|
|
| 39083.3 |
PBR Panel |
Min. 26 ga., 36" wide, through fastened panel over open supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-124.5 Other: Uplift load of -124.5 psf at fastener spacing of 24" o.c. |
Installation Instructions FL39083_R1_II_EvaluationReportC2703_3.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL39083_R1_AE_EvaluationReportC2703_3.pdf Created by Independent Third Party: Yes |
|
|
| 39083.4 |
PBU Panel |
Min. 26 ga., 36" wide, through fastened panel over open supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-120 Other: Uplift load of -120 psf at fastener spacing of 24" o.c. |
Installation Instructions FL39083_R1_II_EvaluationReportC2703_4.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL39083_R1_AE_EvaluationReportC2703_4.pdf Created by Independent Third Party: Yes |