| 45918.1 |
01: 26ga 150SL on plywood |
26ga (min) 150SL on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-63.5 Other: See evaluation report. |
Installation Instructions FL45918_R0_II_26ga_150SL_19in_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL45918_R0_AE_26ga_150SL_19in_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 45918.2 |
02: 032 150SL on plywood |
Nominally 0.032" or thicker 150SL on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-179.5 Other: See evaluation report. |
Installation Instructions FL45918_R0_II_32Al_150SL_plywood_HVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL45918_R0_AE_32Al_150SL_plywood_HVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 45918.3 |
03: 160z 150MS on plywood |
Nominally 16oz copper or thicker 150MS on 15/32" plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-82.25 Other: See evaluation report. |
Installation Instructions FL45918_R0_II_16oz_150MS_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL45918_R0_AE_16oz_150MS_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 45918.4 |
04: 24ga 200MS on B Deck |
24ga (min) 200MS on 22ga (min) B Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-148 Other: See evaluation report. |
Installation Instructions FL45918_R0_II_24ga_200MS_BDeck.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL45918_R0_AE_24ga_200MS_BDeck.pdf Created by Independent Third Party: Yes |
|
|
| 45918.5 |
05: 24ga 200MS on B Deck |
24ga (min) 200MS on 22ga (min) B Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-181.75 Other: See evaluation report. |
Installation Instructions FL45918_R0_II_24ga_200MS_BDeck_b.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL45918_R0_AE_24ga_200MS_BDeck_b.pdf Created by Independent Third Party: Yes |
|
|
| 45918.6 |
06: 032 200MS on B Deck |
Nominally 0.032" or thicker 200MS on 22ga (min) B Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-114.25 Other: See evaluation report. |
Installation Instructions FL45918_R0_II_032_200MS_BDeck.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL45918_R0_AE_032_200MS_BDeck.pdf Created by Independent Third Party: Yes |
|
|
| 45918.7 |
07: 032 200MS on B Deck |
Nominally 0.032" or thicker 200MS on 22ga (min) B Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-166.75 Other: See evaluation report. |
Installation Instructions FL45918_R0_II_032_200MS_BDeck_b.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL45918_R0_AE_032_200MS_BDeck_b.pdf Created by Independent Third Party: Yes |