| 4595.1 |
5V Crimp |
Min. 26 Ga. 5V Crimp Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101.0PSF Other: -78.5 psf @ 16" o.c. Fastener Spacing. -101.0 psf @ 16" o.c. Fastener Spacing. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL4595_R8_II_26 Ga. 5V Crimp Panel over Plywood.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R8_AE_26 Ga. 5V Crimp Panel over Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 4595.2 |
5V Crimp |
Min. 26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101.0PSF Other: -78.5 psf @ 16" o.c. Fastener Spacing. -101.0 psf @ 16" o.c. Fastener Spacing. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL4595_R8_II_26 Ga. 5V Crimp Panel over 1x4 NON HVHZ.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R8_AE_26 Ga. 5V Crimp Panel over 1x4 NON HVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 4595.3 |
Aluminum Mechanical-Seam Lok |
.032" Aluminum Mechanical Lock 16" Wide Roof Panel over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5 psf Other: -78.5 psf @ 18" o.c. clip spacing. -93.5 psf 6" o.c. clip spacing. Install per manufacturer's details. For use in HVHZ Zones. |
Installation Instructions FL4595_R8_II_Aluminum Mechanical-Seam Lok 1.5 over Plywood HVHZ.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R8_AE_Aluminum Mechanical-Seam Lok 1.5 over Plywood HVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 4595.4 |
Aluminum Mechanical-Seam Lok 2" |
.032" Aluminum, 2" Mechanical Lock, 19" Wide Roof Panel over 22 Ga. Steel Deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-138.5psf Other: -71.0 psf @ 24" o.c. clip spacing. -138.5 psf @ 6" o.c. clip spacing. Install per manufacturer's details. For use in HVHZ Zones. |
Installation Instructions FL4595_R8_II_Aluminum Mechanical-Seam Lok 2 over Steel Deck HVHZ.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R8_AE_Aluminum Mechanical-Seam Lok 2 over Steel Deck HVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 4595.5 |
Aluminum TCM Lok |
0.032" Aluminum TCM Lok Roof Panel over 7/16" OSB or 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-112.5psf Other: -75.0 psf at 4 1/2" o.c. fastener spacing. -112.5 psf at 4 1/2" o.c. fastener spacing. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL4595_R8_II_Aluminum TCM Lok over Plywood.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R8_AE_Aluminum TCM Lok over Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 4595.6 |
Mechanical-Seam Lok 1-½" |
1-½" Mechanical Lock, 24 Ga., 16" Wide Roof Panel over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5psf Other: -59.75 psf. @ 24" o.c. clip spacing. -123.5 psf. @ 6" o.c. clip spacing. Install per manufacturer's details. For use in HVHZ Zones. |
Installation Instructions FL4595_R8_II_Mechanical-Seam Lok 1.5 over Plywood HVHZ.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R8_AE_Mechanical-Seam Lok 1.5 over Plywood HVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 4595.7 |
Mechanical-Seam Lok 2" |
2" Mechanical Lock, 24 Ga. Steel, 18-7/8" Wide Roof Panel over 22 Ga. Steel Deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5psf Other: -54.3 psf @ 36" o.c. clip spacing. -153.5 psf @ 6" o.c. clip spacing. Install per manufacturer's details. For use in HVHZ Zones. |
Installation Instructions FL4595_R8_II_Mechanical-Seam Lok 2in 24 Ga. over Steel Deck HVHZ.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R8_AE_Mechanical-Seam Lok 2in 24 Ga. over Steel Deck HVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 4595.8 |
Nail Strip 1" |
1" Nailstrip, 24 Ga. Steel 16" Wide Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5psf Other: -153.5 psf @ 6-3/4" o.c. Fastener Spacing in slot and 12" o.c. Fastener Spacing in pan. -101.0 psf @ 6-3/4" o.c. Fastener Spacing in slot. -59.75 psf @ 16 o.c. Fastener Spacing in slot. Install per Manufacturer's Details. Not for use in HVHZ Zones. |
Installation Instructions FL4595_R8_II_1in Nail Strip over Plywood.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R8_AE_1in Nail Strip over Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 4595.9 |
Nail Strip 1-½" |
1-½" Nail Strip, 24 Ga. 15-½" Wide Roof Panel over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0psf Other: -116.0 psf @ 6-1/2" o.c. Fastener Spacing in slot and 12" o.c. Fastener Spacing in pan. -78.5 psf @ 11" o.c. Fastener Spacing in slot. Install per Manufacturer's Details. For use in HVHZ Zones |
Installation Instructions FL4595_R8_II_1.5 Nailstrip 24 Ga. over Plywood HVHZ.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R8_AE_1.5 Nailstrip 24 Ga. over Plywood HVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 4595.10 |
PBR |
Min. 26 Ga. PBR Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5 PSF Other: -63.5 psf @ 24" o.c. Fastener Spacing. -93.5 psf @ 24" o.c. Fastener Spacing. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL4595_R8_II_26 Ga. PBR Panel over Plywood.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R8_AE_26 Ga. PBR Panel over Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 4595.11 |
PBR |
Min. 26 Ga. PBR Roof Panel over 1x4 Wood Purlins over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-78.5 PSF Other: -71.0 psf @ 24" o.c. Fastener Spacing. -78.5 psf @ 24" o.c. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL4595_R8_II_26 Ga. PBR Panel over 1x4.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R8_AE_26 Ga. PBR Panel over 1x4.pdf Created by Independent Third Party: Yes |
|
|
| 4595.12 |
Snap-Lok 1-½" |
1-½" Snap Lok, 24 Ga. , 16" Wide Roof Panel over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0psf Other: -108.5 psf @12" o.c. Clip spacing. -86.0 psf @ 24" o.c. Clip Spacing. -116.0 psf @ 6" o.c. Clip Spacing. Install per Manufacturer's Details. For use in HVHZ Zones. |
Installation Instructions FL4595_R8_II_1.5 Snap Lock 24 Ga. over Plywood HVHZ.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R8_AE_1.5 Snap Lock 24 Ga. over Plywood HVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 4595.13 |
Snap-Lok 1-¾" |
1-¾" Snap Lock, 24 Ga. Steel, 17-¾" Wide Roof Panel over 22 Ga. Steel Decking |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5psf Other: -71.0 psf @ 24" o.c. Clip Spacing. -108.5 psf @ 6" o.c. Clip Spacing. Install per manufacturer's details. For use in HVHZ Zones. |
Installation Instructions FL4595_R8_II_Snap-Lok 1.75 24 Ga. over Steel Deck HVHZ.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R8_AE_Snap-Lok 1.75 24 Ga. over Steel Deck HVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 4595.14 |
TCM-Lok |
Min. 24 Ga. TCM-Lok Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0PSF Other: -116.0 psf @ 5 1/4" o.c. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL4595_R8_II_TCM-Lok Eval Report.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R8_AE_TCM-Lok Eval Report.pdf Created by Independent Third Party: Yes |
|
|
| 4595.15 |
Ultra-Rib |
Min. 29 Ga. Ultra-Rib Roof Panel over 15/32” Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-146.0PSF Other: -84.3 psf @ 24"o.c.fastener spacing. -146.0 psf @ 12" o.c. fastener spacing. Install per manufacturer's installation details. Not for use in HVHZ Zones. |
Installation Instructions FL4595_R8_II_29 Ga. Ultra-Rib Panel over Plywood.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R8_AE_29 Ga. Ultra-Rib Panel over Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 4595.16 |
Ultra-Rib |
Min. 29 Ga. Ultra Rib, 36" wide, Roof Panel over 1x4 Wood Purlins over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-138.5PSF Other: -93.5 psf @ 24" o.c. fastener spacing. -138.5 psf @ 24" o.c. fastener spacing. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL4595_R8_II_29 Ga. Rib Panel over 1x4.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R8_AE_29 Ga. Rib Panel over 1x4.pdf Created by Independent Third Party: Yes |
|
|
| 4595.17 |
Ultra-Rib |
Min. 29 Ga. Ultra Rib, 36" wide, Roof Panel over 1x4 Wood Purlins over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-86.0PSF Other: -78.5 psf @ 24" o.c. fastener spacing. -86.0 psf @ 24" o.c. fastener spacing. Install per manufactuer's details. Not for use in HVHZ Zones. |
Installation Instructions FL4595_R8_II_29 Ga. Rib Panel over 1x4 with shingles.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R8_AE_29 Ga. Rib Panel over 1x4 with shingles.pdf Created by Independent Third Party: Yes |
|
|
| 4595.18 |
Ultra-Rib |
Min. 29 Ga. Ultra-Rib Roof Panel over 7/16" OSB |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5PSF Other: -41.7 psf @ 24" o.c. fastener spacing. -123.5 psf @ 12" o.c. fastener spacing.
Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL4595_R8_II_29 Ga. Ultra-Rib Panel over OSB.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R8_AE_29 Ga. Ultra-Rib Panel over OSB.pdf Created by Independent Third Party: Yes |
|
|
| 4595.19 |
Ultra-Rib |
29 Ga. Ultra-Rib Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101.0PSF Other: -63.5 psf @ 24" o.c.
- 101.0 psf @ 24" o.c.
Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL4595_R8_II_29 Ga. Ultra-Rib Panel over Plywood with shingles.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R8_AE_29 Ga. Ultra-Rib Panel over Plywood with shingles.pdf Created by Independent Third Party: Yes |
|
|
| 4595.20 |
Ultra-Rib |
29 Ga. Ultra-Rib Roof Panel over 1x4 Wood Purlins over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-131.0PSF Other: -52.5 psf @ 24" o.c. fastener spacing. -131.0 psf @ 6" o.c. fastener spacing. Install per manufacturer's details. Not for use in HVHZ Zones. |