| 33230.1 |
7.2 Panel (S1) 2' - 5' Spans |
36" Wide x 24 Ga. (min.) Steel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +N/A/-159.70 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Allowable Wind Uplift Pressure, psf. Panel Span, ft: -159.70 @ 2‘, -132.70 @ 3', -105.80 @ 4', -78.85 @ 5‘. Not for use in HVHZ. Safety Factor of 2.0 is included. |
Installation Instructions FL33230_R7_II_Installation Details ALL.pdf FL33230_R7_II_Negative Load Table 2 to 5 FT spans.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL33230_R7_TR_2651A0001 Report ASTM E1886 Petersen 24ga 7.2 Rib Panel.pdf FL33230_R7_TR_T277-08_e1592_24_GA.pdf |
|
|
| 33230.2 |
7.2 Panel (S2) 2' - 5' Spans |
36" Wide x .032" (min.) Aluminum |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-104.0 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Allowable Wind Uplift Pressure, psf. Panel Span, ft: -104.0 @ 2‘, -89.7 @ 3', -75.4 @ 4', -61.1 @ 5‘. Not for use in HVHZ. Safety Factor of 2.0 is included. |
Installation Instructions FL33230_R7_II_Installation Details ALL.pdf FL33230_R7_II_Negative Load Table alum 2 to 5 FT spans.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL33230_R7_TR_T281-08_e1592_032.pdf |
|
|
| 33230.3 |
7.2 Panel (S3) 1' - 5' Spans |
36" Wide x .050" (min.) Aluminum |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-192.10 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Allowable Wind Uplift Pressure, psf. Panel Span, ft: -192.10 @ 1‘, -162.20 @ 2', -132.40 @ 3', -102.50 @ 4', -72.75 @ 5‘. Not for use in HVHZ. Safety Factor of 2.0 is included. |
Installation Instructions FL33230_R7_II_Installation Details ALL.pdf FL33230_R7_II_Negative Load Table 1 to 5 FT spans.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL33230_R7_TR_ALL test reports 1 FT to 5 FT spans.pdf |
|
|
| 33230.4 |
7.2 Panel (S4) 7 - 10' Spans |
36" Wide x .050" (min.) Aluminum |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-57.20 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Allowable Wind Uplift Pressure, psf. Panel Span, ft: -57.20 @ 7‘, -48.50 @ 8‘, -39.85 @ 9‘, -31.20 @ 10‘. Not for use in HVHZ. Safety Factor of 2.0 is included. |
Installation Instructions FL33230_R7_II_Installation Details ALL.pdf FL33230_R7_II_Negative Load Table 7 to 10 FT spans.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL33230_R7_TR_T302-22_050_7_and_10_FT.pdf |
|
|
| 33230.5 |
Board & Batten (A1) |
12" thru 16" wide x .032" (min.) Aluminum |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +100/-84 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Metal panels & metal siding installed in front of CBS construction or 5/8" plywood supported by 2x studs or 2x6 – 18 Ga. metal studs, each at 16" o.c. are exempt from impact & positive pressure tests. |
Installation Instructions FL33230_R7_II_Installation Details ALL.pdf Verified By: Donald Flood 31333 Test Reports FL33230_R7_TR_2651T0006A Report for TAS-202 and TAS-203 in 0.032 Aluminum Board and Batten.pdf FL33230_R7_TR_2651T0008A.01 Report for E283 and E331 Board and Batten.pdf |
|
|
| 33230.6 |
Board & Batten (S1) |
12" thru 16" wide x 24 Ga. (min.) Steel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +120/-112 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Metal panels & metal siding installed in front of CBS construction or 5/8" plywood supported by 2x studs or 2x6 – 18 Ga. metal studs, each at 16" o.c. are exempt from impact & positive pressure tests. |
Installation Instructions FL33230_R7_II_Installation Details ALL.pdf Verified By: Donald Flood 31333 Test Reports FL33230_R7_TR_2651T0007A Report for TAS-202 and TAS-203 in 24 ga. Steel Board and Batten.pdf FL33230_R7_TR_2651T0008A.01 Report for E283 and E331 Board and Batten.pdf |
|
|
| 33230.7 |
Box Rib 1 (A1) |
12" Wide x .032" (min.) Aluminum w/Clip |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-57.3 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Allowable Wind Uplift Pressure, psf. Panel Span, ft: -57.3 @ 2‘, -53.4 @ 2.5‘, -49.5 @ 3‘, -45.6 @ 3.5‘, -41.6 @ 4‘, -37.7 @ 4.5‘, -33.8 @ 5‘. Not for use in HVHZ. |
Installation Instructions FL33230_R7_II_PAC Box Rib 1 details.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL33230_R7_TR_ASTM E-1592_Box Rib_1 x .032 (min.) Alum with clip and loads.pdf FL33230_R7_TR_PAC Box Rib 1 x .032 Alum w Clip ASTM 1592 Summary Load Chart.pdf |
|
|
| 33230.8 |
Box Rib 1 (A2) |
12" Wide x 24 Ga. (min.) Steel w/Clip |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-80.6 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Allowable Wind Uplift Pressure, psf. Panel Span, ft: -80.6 @ 2‘, -74.5 @ 2.5‘, -68.5 @ 3‘, -62.4 @ 3.5‘, -56.3 @ 4‘, -50.3 @ 4.5‘, -44.2 @ 5‘. Not for use in HVHZ. |
Installation Instructions FL33230_R7_II_PAC Box Rib 1 details.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL33230_R7_TR_ASTM E-1592_Box Rib_1 x 24 GA (min.) Steel with clip and loads.pdf FL33230_R7_TR_PAC Box Rib 1 x 24 GA w Clip ASTM 1592 Summary Load Chart.pdf |
|
|
| 33230.9 |
Box Rib 1 (A2.1-HVHZ) |
12" Wide x 24 Ga. (min.) Steel w/Clip (HVHZ) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +75/-75 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Meets Florida Building Code, Section 1620 and Section 1625. Product must be installed in front of 3/4" plywood that meets impact resistant requirements. |
Installation Instructions FL33230_R7_II_T169-25 PETERSEN HVHZ.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL33230_R7_TR_T169-25 PETERSEN HVHZ.pdf |
|
|
| 33230.10 |
Box Rib 2 (A3) |
12" Wide x .032" (min.) Aluminum w/Clip |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101.4 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Allowable Wind Uplift Pressure, psf. Panel Span, ft: -101.4 @ 2‘, -91.5 @ 2.5‘, -81.5 @ 3‘, -71.6 @ 3.5‘, -61.6 @ 4‘, -51.7 @ 4.5‘, -41.7 @ 5‘. Not for use in HVHZ. |
Installation Instructions FL33230_R7_II_PAC Box Rib 2 details.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL33230_R7_TR_ASTM E-1592_Box Rib_2 x .032 (min.) Alum with clip and loads.pdf FL33230_R7_TR_PAC Box Rib 2 x .032 Alum w Clip ASTM 1592 Summary Load Chart.pdf |
|
|
| 33230.11 |
Box Rib 2 (A4) |
12" Wide x 24 Ga. (min.) Steel w/Clip |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-88.5 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Allowable Wind Uplift Pressure, psf. Panel Span, ft: -88.5 @ 2‘, -79.8 @ 2.5‘, -71.2 @ 3‘, -62.5 @ 3.5‘, -53.8 @ 4‘, -45.2 @ 4.5‘, -36.5 @ 5‘. Not for use in HVHZ. |
Installation Instructions FL33230_R7_II_PAC Box Rib 2 details.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL33230_R7_TR_ASTM E-1592_Box Rib-2 x 24 GA (min.) Steel with clip and loads.pdf FL33230_R7_TR_PAC Box Rib 2 x 24 GA w Clip ASTM 1592 Summary Load Chart.pdf |
|
|
| 33230.12 |
Box Rib 3 (A5) |
12" Wide x .032" (min.) Aluminum w/Clip |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-75.4 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Allowable Wind Uplift Pressure, psf. Panel Span, ft: -75.4 @ 2’, -69.3 @ 2.5’, -63.3 @ 3’, -57.2 @ 3.5’, -51.1@ 4’, -45.1 @ 4.5’, -39.0 @ 5’. Not for use in HVHZ. |
Installation Instructions FL33230_R7_II_PAC Box Rib 3 details.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL33230_R7_TR_ASTM E-1592_Box Rib_3 x .032 (min.) Alum with clip and loads.pdf FL33230_R7_TR_PAC Box Rib 3 x 0.032 Alum w Clip ASTM 1592 Summary Load Table.pdf |
|
|
| 33230.13 |
Box Rib 3 (A6) |
12" Wide x 24 Ga. (min.) Steel w/Clip |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-78.0 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Allowable Wind Uplift Pressure, psf. Panel Span, ft: -78.0 @ 2’, -73.2 @ 2.5’, -68.5 @ 3’, -63.7 @ 3.5’, -58.9 @ 4’, -54.1 @ 4.5’, -49.4 @ 5’. Not for use in HVHZ. |
Installation Instructions FL33230_R7_II_PAC Box Rib 3 details.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL33230_R7_TR_ASTM E-1592_Box Rib_3 x 24 GA (min.) Steel with clip and loads.pdf FL33230_R7_TR_PAC Box Rib 3 x 24 GA w Clip ASTM 1592 Summary Load Table.pdf |
|
|
| 33230.14 |
Box Rib 4 (A7) |
12" Wide x .032" (min.) Aluminum w/Clip |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-85.6 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Allowable Wind Uplift Pressure, psf. Panel Span, ft: -85.6 @ 2’, -78.3 @ 2.5’, -71.0 @ 3’, -63.7 @ 3.5’, -56.3 @ 4’, -49.0 @ 4.5’, -41.7 @ 5’. Not for use in HVHZ. |
Installation Instructions FL33230_R7_II_PAC Box Rib 4 details.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL33230_R7_TR_ASTM E-1592_Box Rib_4 x .032 (min.) Alum with clip and loads.pdf FL33230_R7_TR_PAC Box Rib 4 x 0.032 Alum w Clip ASTM 1592 Summary Load Table.pdf |
|
|
| 33230.15 |
Box Rib 4 (A8) |
12" Wide x 24 Ga. (min.) Steel w/Clip |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-105.2 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Allowable Wind Uplift Pressure, psf. Panel Span, ft: -105.2 @ 2‘, -95.0 @ 2.5‘, -84.8 @ 3‘, -74.5 @ 3.5‘, -64.3 @ 4’, -54.0 @ 4.5‘, -43.7 @ 5‘. Not for use in HVHZ.
|
Installation Instructions FL33230_R7_II_PAC Box Rib 4 details.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL33230_R7_TR_ASTM E-1592_Box Rib_4 x 24 GA (min.) Steel with clip and loads.pdf FL33230_R7_TR_PAC Box Rib 4 x 24 GA w Clip ASTM 1592 Summary Load Table.pdf |
|
|
| 33230.16 |
Flush Series Wall Panel (HVHZ) |
0.032" (min.) Aluminum Wall Panel, 12" Wide (HVHZ) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +120/-120 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Please see Test Report for Limits of Use. |
Installation Instructions FL33230_R7_II_s6485.01-450-18-r0.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - West Palm Beach, FL Test Reports FL33230_R7_TR_s6485.01-450-18-r0.pdf |
|
|
| 33230.17 |
Flush Series Wall Panel (HVHZ) |
24 Ga. (min.) Steel Wall Panel, 12" Wide (HVHZ) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +120/-120 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Please see Test Report for Limits of Use. |
Installation Instructions FL33230_R7_II_s6485.03-450-18-r0.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - West Palm Beach, FL Test Reports FL33230_R7_TR_s6485.03-450-18-r0.pdf |
|
|
| 33230.18 |
Modular AL (050) |
3" deep x 24" wide x 0.050" (min.) Aluminum |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-57.2 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Allowable Wind Uplift Pressure, psf. Panel Span, ft: -57.2 @ (24") 2.0'. Not for use in HVHZ. |
Installation Instructions FL33230_R7_II_PAC Modular AL details.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL33230_R7_TR_ASTM E1592_3 in deep x 24 in x 0.050 in (min.) Aluminum.pdf |
|
|
| 33230.19 |
Modular AL (080) |
3" deep x 30" wide x 0.080" (min.) Aluminum |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-57.2 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Allowable Wind Uplift Pressure, psf. Panel Span, ft: -57.2 @ (30") 2.5'. Not for use in HVHZ. |
Installation Instructions FL33230_R7_II_PAC Modular AL details.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL33230_R7_TR_ASTM E1592_3 in deep x 30 in x 0.080 in (min.) Aluminum.pdf |
|
|
| 33230.20 |
Reveal Series Wall Panel (HVHZ) |
24 Ga. (min.) Steel Wall Panel, 12" Wide (HVHZ) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +120/-120 Other: Corrosion Resistance – Saltwater Environments: Fasteners and connectors, if applicable, in areas within 3,000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. Please see Test Report for Limits of Use. |
Installation Instructions FL33230_R7_II_s6485.03-450-18-r0.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - West Palm Beach, FL Test Reports FL33230_R7_TR_s6485.03-450-18-r0.pdf |