Product Approval Menu > Application Detail
 
FL # FL33230-R3
Application Type Revision
Code Version 2020
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Petersen Aluminum Corp.
Address/Phone/Email 102 Northpoint Parkway
Building 106
Acworth, GA 30102
(954) 461-7055
ndelfino@petersenmail.com
 
Authorized Signature Sal Delfino
sdelfino@petersenmail.com
 
Technical Representative Sal Delfino
Address/Phone/Email 102 Northpoint Parkway
Building 106
Acworth, GA 30102
(954) 931-1392
sdelfino@petersenmail.com
 
Quality Assurance Representative Nick Delfino
Address/Phone/Email 1500 N. University Drive
Suite 201-G
Coral Springs, FL 33071
(954) 461-7055
ndelfino@petersenmail.com
 
Category Panel Walls
Subcategory Siding
 
Compliance Method Test Report
 
Testing Lab Farabaugh Engineering and Testing, Inc.
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2023
Validated By Donald Flood, FL PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL33230_R3_COI_COI Farabaugh FET.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E15922005
 
Equivalence of Product Standards
Certified By

Approved Testing Lab
FL33230_R3_Equiv_Equivalency of Standard letters 08-05-22.pdf
FL33230_R3_Equiv_Equivalency of Standard letters 12-13-22.pdf
 
 
 
 
Product Approval Method Method 1 Option B
 
Date Submitted 11/23/2022
Date Validated 12/22/2022
Date Pending FBC Approval 12/28/2022
Date Approved 02/07/2023
Date Revised 09/20/2023
 
Summary of Products
FL # Model, Number or Name Description
33230.1 7.2 Panel (S1) 2' - 5' Spans 36" Wide x 24 Ga. (min.) Steel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-159.70
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -159.70 @ 2‘, -132.70 @ 3', -105.80 @ 4', -78.85 @ 5‘. Not for use in HVHZ. Safety Factor of 2.0 is included.
Installation Instructions
 FL33230_R3_II_Installation Details ALL.pdf
 FL33230_R3_II_Negative Load Table 2 to 5 FT spans.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R3_TR_T277-08_e1592_24_GA.pdf
33230.2 7.2 Panel (S2) 2' - 5' Spans 36" Wide x .032" (min.) Aluminum
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-104.0
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -104.0 @ 2‘, -89.7 @ 3', -75.4 @ 4', -61.1 @ 5‘. Not for use in HVHZ. Safety Factor of 2.0 is included.
Installation Instructions
 FL33230_R3_II_Installation Details ALL.pdf
 FL33230_R3_II_Negative Load Table alum 2 to 5 FT spans.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R3_TR_T281-08_e1592_032.pdf
33230.3 7.2 Panel (S3) 1' - 5' Spans 36" Wide x .050" (min.) Aluminum
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-192.10
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -192.10 @ 1‘, -162.20 @ 2', -132.40 @ 3', -102.50 @ 4', -72.75 @ 5‘. Not for use in HVHZ. Safety Factor of 2.0 is included.
Installation Instructions
 FL33230_R3_II_Installation Details ALL.pdf
 FL33230_R3_II_Negative Load Table 1 to 5 FT spans.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R3_TR_ALL test reports 1 FT to 5 FT spans.pdf
33230.4 7.2 Panel (S4) 7 - 10' Spans 36" Wide x .050" (min.) Aluminum
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-57.20
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -57.20 @ 7‘, -48.50 @ 8‘, -39.85 @ 9‘, -31.20 @ 10‘. Not for use in HVHZ. Safety Factor of 2.0 is included.
Installation Instructions
 FL33230_R3_II_Installation Details ALL.pdf
 FL33230_R3_II_Negative Load Table 7 to 10 FT spans.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R3_TR_T302-22_050_7_and_10_FT.pdf
33230.5 Box Rib 1 (A1) 12" Wide x .032" (min.) Aluminum w/Clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-57.3
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -57.3 @ 2‘, -53.4 @ 2.5‘, -49.5 @ 3‘, -45.6 @ 3.5‘, -41.6 @ 4‘, -37.7 @ 4.5‘, -33.8 @ 5‘. Not for use in HVHZ.
Installation Instructions
 FL33230_R3_II_PAC Box Rib 1 details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R3_TR_ASTM E-1592_Box Rib_1 x .032 (min.) Alum with clip and loads.pdf
33230.6 Box Rib 1 (A2) 12" Wide x 24 Ga. (min.) Steel w/Clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-80.6
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -80.6 @ 2‘, -74.5 @ 2.5‘, -68.5 @ 3‘, -62.4 @ 3.5‘, -56.3 @ 4‘, -50.3 @ 4.5‘, -44.2 @ 5‘. Not for use in HVHZ.
Installation Instructions
 FL33230_R3_II_PAC Box Rib 1 details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R3_TR_ASTM E-1592_Box Rib_1 x 24 GA (min.) Steel with clip and loads.pdf
33230.7 Box Rib 2 (A3) 12" Wide x .032" (min.) Aluminum w/Clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-101.4
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -101.4 @ 2‘, -91.5 @ 2.5‘, -81.5 @ 3‘, -71.6 @ 3.5‘, -61.6 @ 4‘, -51.7 @ 4.5‘, -41.7 @ 5‘. Not for use in HVHZ.
Installation Instructions
 FL33230_R3_II_PAC Box Rib 2 details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R3_TR_ASTM E-1592_Box Rib_2 x .032 (min.) Alum with clip and loads.pdf
33230.8 Box Rib 2 (A4) 12" Wide x 24 Ga. (min.) Steel w/Clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-88.5
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -88.5 @ 2‘, -79.8 @ 2.5‘, -71.2 @ 3‘, -62.5 @ 3.5‘, -53.8 @ 4‘, -45.2 @ 4.5‘, -36.5 @ 5‘. Not for use in HVHZ.
Installation Instructions
 FL33230_R3_II_PAC Box Rib 2 details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R3_TR_ASTM E-1592_Box Rib-2 x 24 GA (min.) Steel with clip and loads.pdf
33230.9 Box Rib 3 (A5) 12" Wide x .032" (min.) Aluminum w/Clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-75.4
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -75.4 @ 2’, -69.3 @ 2.5’, -63.3 @ 3’, -57.2 @ 3.5’, -51.1@ 4’, -45.1 @ 4.5’, -39.0 @ 5’. Not for use in HVHZ.
Installation Instructions
 FL33230_R3_II_PAC Box Rib 3 details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R3_TR_ASTM E-1592_Box Rib_3 x .032 (min.) Alum with clip and loads.pdf
33230.10 Box Rib 3 (A6) 12" Wide x 24 Ga. (min.) Steel w/Clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-78.0
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -78.0 @ 2’, -73.2 @ 2.5’, -68.5 @ 3’, -63.7 @ 3.5’, -58.9 @ 4’, -54.1 @ 4.5’, -49.4 @ 5’. Not for use in HVHZ.
Installation Instructions
 FL33230_R3_II_PAC Box Rib 3 details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R3_TR_ASTM E-1592_Box Rib_3 x 24 GA (min.) Steel with clip and loads.pdf
33230.11 Box Rib 4 (A7) 12" Wide x .032" (min.) Aluminum w/Clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-85.6
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -85.6 @ 2’, -78.3 @ 2.5’, -71.0 @ 3’, -63.7 @ 3.5’, -56.3 @ 4’, -49.0 @ 4.5’, -41.7 @ 5’. Not for use in HVHZ.
Installation Instructions
 FL33230_R3_II_PAC Box Rib 4 details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R3_TR_ASTM E-1592_Box Rib_4 x .032 (min.) Alum with clip and loads.pdf
33230.12 Box Rib 4 (A8) 12" Wide x 24 Ga. (min.) Steel w/Clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-105.2
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -105.2 @ 2‘, -95.0 @ 2.5‘, -84.8 @ 3‘, -74.5 @ 3.5‘, -64.3 @ 4’, -54.0 @ 4.5‘, -43.7 @ 5‘. Not for use in HVHZ.
Installation Instructions
 FL33230_R3_II_PAC Box Rib 4 details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R3_TR_ASTM E-1592_Box Rib_4 x 24 GA (min.) Steel with clip and loads.pdf
33230.13 Modular AL (050) 3" deep x 24" wide x 0.050" (min.) Aluminum
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-57.2
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -57.2 @ (24") 2.0'. Not for use in HVHZ.
Installation Instructions
 FL33230_R3_II_PAC Modular AL details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R3_TR_ASTM E1592_3 in deep x 24 in x 0.050 in (min.) Aluminum.pdf
33230.14 Modular AL (080) 3" deep x 30" wide x 0.080" (min.) Aluminum
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-57.2
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -57.2 @ (30") 2.5'. Not for use in HVHZ.
Installation Instructions
 FL33230_R3_II_PAC Modular AL details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R3_TR_ASTM E1592_3 in deep x 30 in x 0.080 in (min.) Aluminum.pdf
 