| 33286.1 |
EF [04 or 08] E-Class |
Aluminum Frame Self-Flashed Fixed Skylight, (non-impact), size 4646 and smaller (426-H-725.00/.01) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +160/-60 Other: SKG-PG60, max size 1295mm x 1295mm (51" x 51"). PG 60 means minimum capacity is 60 psf. Glass meets ASTM E1300: 3.9mm clear tempered/8.5mm st. stl. spacer/5.3mm laminate using two 2.3mm panes and 0.030" PVB interlayer (with white coating for variant 08). Anchoring to roof deck: mounting bracket spacing approx. 6" from corners (4" on 14" side) and in the middle of side when 3 are used, fill all pre-punched holes in mounting brackets with supplied screws. |
Certification Agency Certificate FL33286_R3_C_CAC_VELUX CCL_EF 4646_04-08.pdf Quality Assurance Contract Expiration Date 12/17/2030 Installation Instructions FL33286_R3_II_EClass-Asphalt-Shingle-Installation_0519.pdf FL33286_R3_II_Eclass-Metal-Roof-Installation_Instructions 0518.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 33286.2 |
EF [04 or 08] E-Class |
Aluminum Frame Self-Flashed Fixed Skylight, (non-impact), size 3054 and smaller (426-H-725.04/.05) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +160/-60 Other: SKG-PG60, max size 914mm x 1524mm (36" x 60"). PG 60 means minimum capacity is 60 psf. Glass meets ASTM E1300: 3mm clear tempered/10.5mm st. stl. spacer/5.3mm laminate using two 2.3mm panes and 0.030" PVB interlayer (with white coating for variant 08). Anchoring to roof deck: mounting bracket spacing approx. 6" from corners (4" on 14" side) and in the middle of side when 3 are used, fill all pre-punched holes in mounting brackets with supplied screws. |
Certification Agency Certificate FL33286_R3_C_CAC_VELUX CCL_EF 3054_04-08.pdf Quality Assurance Contract Expiration Date 12/17/2030 Installation Instructions FL33286_R3_II_EClass-Asphalt-Shingle-Installation_0519.pdf FL33286_R3_II_Eclass-Metal-Roof-Installation_Instructions 0518.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 33286.3 |
EF [06 or 16] E-Class (Impact) |
Aluminum Frame Self-Flashed Fixed Skylight, (Impact), size 3054 and smaller (426-H-725.08/.09/.12) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +160/-60 Other: Wind Zone 3, Missile Level C, Cycle Press. +/- 60, max size 914mm x 1524mm (36" x 60"). Tested ASTM E1886/E1996. Glass meets ASTM E1300: 3mm clear temp Lo-E366 (Lo-E340 on 16)/10.5mm st. stl. spacer/7mm laminate using 2 2.3mm panes & 3 0.030" PVB interlayers. Anchoring to roof deck: mounting bracket spacing approx. 6" from corners (4" on 14" side) and in the middle of side when 3 are used, fill all pre-punched holes in mounting brackets with supplied screws. |
Certification Agency Certificate FL33286_R3_C_CAC_VELUX CCL_EF 3054_06-16.pdf Quality Assurance Contract Expiration Date 12/17/2030 Installation Instructions FL33286_R3_II_EClass-Asphalt-Shingle-Installation_0519.pdf FL33286_R3_II_Eclass-Metal-Roof-Installation_Instructions 0518.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 33286.4 |
EF [06 or 16] E-Class (Impact) |
Aluminum Frame Self-Flashed Fixed Skylight, (Impact), size 4646 and smaller (426-H-725.13/.14/.17) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +160/-60 Other: Wind Zone 3, Missile Level C, Cycle Press. +/- 60, max size 1295mm x 1295mm (51" x 51"). Tested ASTM E1886/E1996. Glass meets ASTM E1300: 3.9mm clear temp Lo-E366 (Lo-E340 on 16)/10.5mm st. stl. spacer/7mm laminate using 2 2.3mm panes & 3 0.030" PVB interlayers. Anchoring to roof deck: mounting bracket spacing approx. 6" from corners (4" on 14" side) and in the middle of side when 3 are used, fill all pre-punched holes in mounting brackets with supplied screws. |
Certification Agency Certificate FL33286_R3_C_CAC_VELUX CCL_EF 4646_06-16.pdf Quality Assurance Contract Expiration Date 12/17/2030 Installation Instructions FL33286_R3_II_EClass-Asphalt-Shingle-Installation_0519.pdf FL33286_R3_II_Eclass-Metal-Roof-Installation_Instructions 0518.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 33286.5 |
EV [04 or 08] E-Class |
Aluminum Frame Self-Flashed Manual-Venting Skylight, (non-impact), size 4646 and smaller (426-H-729.00/.01) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: SKG-PG40, max size 1295mm x 1295mm (51" x 51"). PG 40 means minimum capacity is 40 psf. Glass meets ASTM E1300: 3.9mm clear tempered/8.5mm st. stl. spacer/5.3mm laminate using two 2.3mm panes and 0.030" PVB interlayer (with white coating for variant 08). Anchoring to roof deck: mounting bracket spacing approx. 6" from corners (4" on 14" side) and in the middle of side when 3 are used, fill all pre-punched holes in mounting brackets with supplied screws. |
Certification Agency Certificate FL33286_R3_C_CAC_VELUX CCL_EV 4646_04-08.pdf Quality Assurance Contract Expiration Date 10/01/2030 Installation Instructions FL33286_R3_II_EClass-Asphalt-Shingle-Installation_0519.pdf FL33286_R3_II_Eclass-Metal-Roof-Installation_Instructions 0518.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 33286.6 |
EV [04 or 08] E-Class |
Aluminum Frame Self-Flashed Manual-Venting Skylight, (non-impact), size 3054 and smaller (426-H-729.08/.09) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: SKG-PG40, max size 889mm x 1499mm (36" x 60"). PG 40 means minimum capacity is 40 psf. Glass meets ASTM E1300: 3mm clear tempered/10.5mm st. stl. spacer/5.3mm laminate using two 2.3mm panes and 0.030" PVB interlayer (with white coating for variant 08). Anchoring to roof deck: mounting bracket spacing approx. 6" from corners (4" on 14" side) and in the middle of side when 3 are used, fill all pre-punched holes in mounting brackets with supplied screws. |
Certification Agency Certificate FL33286_R3_C_CAC_VELUX CCL_EV 3054_04-08.pdf Quality Assurance Contract Expiration Date 10/01/2030 Installation Instructions FL33286_R3_II_EClass-Asphalt-Shingle-Installation_0519.pdf FL33286_R3_II_Eclass-Metal-Roof-Installation_Instructions 0518.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 33286.7 |
EVMS [04 or 08] E-Class |
Aluminum Frame Solar-Powered Venting Skylight, (non-impact), size 4646 and smaller (426-H-729.04/.05) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: SKG-PG40, max size 1295mm x 1295mm (51" x 51"). PG 40 means minimum capacity is 40 psf. Glass meets ASTM E1300: 3.9mm clear tempered/8.5mm st. stl. spacer/5.3mm laminate using two 2.3mm panes and 0.030" PVB interlayer (with white coating for variant 08). Anchoring to roof deck: mounting bracket spacing approx. 6" from corners (4" on 14" side) and in the middle of side when 3 are used, fill all pre-punched holes in mounting brackets with supplied screws. |
Certification Agency Certificate FL33286_R3_C_CAC_VELUX CCL_EVMS 4646_04-08.pdf Quality Assurance Contract Expiration Date 10/01/2030 Installation Instructions FL33286_R3_II_EClass-Asphalt-Shingle-Installation_0519.pdf FL33286_R3_II_Eclass-Metal-Roof-Installation_Instructions 0518.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 33286.8 |
EVMS [04 or 08] E-Class |
Aluminum Frame Solar-Powered Venting Skylight, (non-impact), size 3054 and smaller (426-H-729.12/.13) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: SKG-PG40, max size 889mm x 1499mm (36" x 60"). PG 40 means minimum capacity is 40 psf. Glass meets ASTM E1300: 3mm clear tempered/10.5mm st. stl. spacer/5.3mm laminate using two 2.3mm panes and 0.030" PVB interlayer (with white coating for variant 08). Anchoring to roof deck: mounting bracket spacing approx. 6" from corners (4" on 14" side) and in the middle of side when 3 are used, fill all pre-punched holes in mounting brackets with supplied screws. |
Certification Agency Certificate FL33286_R3_C_CAC_VELUX CCL_EVMS 3054_04-08.pdf Quality Assurance Contract Expiration Date 10/01/2030 Installation Instructions FL33286_R3_II_EClass-Asphalt-Shingle-Installation_0519.pdf FL33286_R3_II_Eclass-Metal-Roof-Installation_Instructions 0518.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 33286.9 |
GSM SKYMAX (Impact) 99-200 Level |
GSM SKYMAX (Impact) 99-200 Level curb-mount skylight |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +150/-80 Other: SKG-PG80, max size 1320mm x 2438mm (52 in x 96 in). PG80 means minimum capacity is 80 psf. Insulated glazing uses .090 pvb interlayer. Product approved for Wind Zone 3, Missile Level C. Details for anchoring to site-built curb in installation instructions. |
Certification Agency Certificate FL33286_R3_C_CAC_GSM Skymax [5296 or smaller] Impact.pdf Quality Assurance Contract Expiration Date 10/08/2030 Installation Instructions FL33286_R3_II_GSM Skymax Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 33286.10 |
GSM SKYMAX 38120 99-100 Level |
GSM SKYMAX (non-impact) 99-100 Level curb-mount skylight |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +110/-80 Other: SKG-PG80, max size 972mm x 3080mm (38.25 in x 121.25 in). PG80 means minimum capacity is 80 psf. Insulated glazing uses .060 pvb interlayer. Details for anchoring to site-built curb in installation instructions. |
Certification Agency Certificate FL33286_R3_C_CAC_GSM Skymax 38120 Non-impact_AWS_11-17_NCTL-210-4204-1.pdf Quality Assurance Contract Expiration Date 01/16/2031 Installation Instructions FL33286_R3_II_GSM Skymax Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 33286.11 |
GSM SKYMAX 4896 99-100 Level |
GSM SKYMAX (non-impact) 99-100 Level curb-mount skylight |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +160/-80 Other: SKG-PG80, max size 1251mm x 2470mm (49.25 in x 97.25 in). PG80 means minimum capacity is 80 psf. Insulated glazing uses .060 pvb interlayer. Details for anchoring to site-built curb in installation instructions. |
Certification Agency Certificate FL33286_R3_C_CAC_GSM Skymax 4896 Non-impact_AWS_11-17_NCTL-210-4204-1.pdf Quality Assurance Contract Expiration Date 01/16/2031 Installation Instructions FL33286_R3_II_GSM Skymax Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |