| 29444.1 |
01: IM 5VC 5V Crimp 26ga |
IM 5VC 5V Crimp panel from 26ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-206 Other: See evaluation report. |
Installation Instructions FL29444_R3_II_26ga_5V_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29444_R3_AE_26ga_5V_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 29444.2 |
02: IM 5VC 5V Crimp 032 Aluminum |
IM 5VC 5V Crimp panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-183.5 Other: See evaluation report. |
Installation Instructions FL29444_R3_II_32Al_5VC_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29444_R3_AE_32Al_5VC_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 29444.3 |
03: IM 5VC 5V Crimp 26ga |
IM 5VC 5V Crimp panel from 26ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-206 Other: See evaluation report. |
Installation Instructions FL29444_R3_II_26ga_5VC_plywood-nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29444_R3_AE_26ga_5VC_plywood-nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 29444.4 |
04: IM 5VC 5V Crimp 032 Aluminum |
IM 5VC 5V Crimp panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-183.5 Other: See evaluation report. |
Installation Instructions FL29444_R3_II_32Al_5VC_plywood-nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29444_R3_AE_32Al_5VC_plywood-nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 29444.5 |
05: IM 75COR Corrugated 26ga |
IM 75COR 0.75" Corrugated panels from 26ga(min) on 2x4 (nom) battens |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-161 Other: See evaluation report. |
Installation Instructions FL29444_R3_II_26ga_75COR_battens-nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29444_R3_AE_26ga_75COR_battens-nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 29444.6 |
06: IM 75COR Corrugated 26ga |
IM 75COR 0.75" Corrugated panels from 26ga(min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-161 Other: See evaluation report. |
Installation Instructions FL29444_R3_II_26ga_75COR_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29444_R3_AE_26ga_75COR_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 29444.7 |
07: IM 36TR Rib 26ga |
IM 36TR Trapezoidal Rib panel from 26ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-78.5 Other: See evaluation report. |
Installation Instructions FL29444_R3_II_26ga_36TR_plywood im.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29444_R3_AE_26ga_36TR_plywood im.pdf Created by Independent Third Party: Yes |
|
|
| 29444.8 |
08: IM 36TR Rib 26ga |
IM 36TR Trapezoidal Rib panel from 26ga (min) on 17/32" (min) OSB, plywood, or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5 Other: See evaluation report. |
Installation Instructions FL29444_R3_II_26ga_36TR_OSB im.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29444_R3_AE_26ga_36TR_OSB im.pdf Created by Independent Third Party: Yes |
|
|
| 29444.9 |
09: IM 36TR Rib 29ga |
IM 36TR Trapezoidal Rib panel from 29ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-146 Other: See evaluation report. |
Installation Instructions FL29444_R3_II_29ga_IM36TR_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29444_R3_AE_29ga_IM36TR_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 29444.10 |
10: IM 36PBR 26ga |
IM 36PBR R/PBR panel from 26ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-119.5 Other: See evaluation report. |
Installation Instructions FL29444_R3_II_26ga_IM36PBR_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29444_R3_AE_26ga_IM36PBR_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 29444.11 |
10: IM 5VC 5V Crimp 26ga |
IM 5VC 5V Crimp panel from 26ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-168.5 Other: See evaluation report. |
Installation Instructions FL29444_R3_II_26ga_5VC_12-6_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29444_R3_AE_26ga_5VC_12-6_plywood.pdf Created by Independent Third Party: Yes |