| 8768.1 |
CURRIES in-swing and out-swing door frames |
8'4" x 8'0" frames. Reinforced Hollow metal mullion may be used. Hollow metal mullion must be welded. RD0448R3 CURRIES Installation Instructions. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Desgin Pressure Varies,Not qualified for water infiltration; Exit devices not allowed for in-swing; Qualified for HVHZ and Large Missile Impact. |
Certification Agency Certificate FL8768_R6_C_CAC_Intertek_Listing_Door Frames.pdf Quality Assurance Contract Expiration Date 12/31/2026 Installation Instructions FL8768_R6_II_Installation Instructions RD0448_Rev3.pdf FL8768_R6_II_Product Summary RD0447_Rev4.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 8768.2 |
CURRIES Model 707, 727, and 747 out-swing doors |
CURRIES 707, 727, or 747 4’0” x 8’0” Flush, Glazed, or Louvered pairs of doors. May use Rockwood WLV60 Louver or a FBC Approved Louver. See RD0448R3 CURRIES Installation Instructions. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: Not qualified for water infiltration; Qualified for HVHZ; Qualified for Large Missile Impact. |
Certification Agency Certificate FL8768_R6_C_CAC_Intertek_Listing_707 727 747 70PSF Singles and Pairs.pdf Quality Assurance Contract Expiration Date 12/31/2026 Installation Instructions FL8768_R6_II_Installation Instructions RD0448_Rev3.pdf FL8768_R6_II_Product Summary RD0447_Rev4.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 8768.3 |
CURRIES Model 707, 727, and 747 out-swing doors |
CURRIES 707, 727, or 747 4’0” x 8’0” Flush, Glazed, or Louvered single doors. May use Rockwood WLV60 Louver or a FBC Approved Louver. See RD0448R3 CURRIES Installation Instructions. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: Not qualified for water infiltration; Qualified for HVHZ and Large Missile Impact. |
Certification Agency Certificate FL8768_R6_C_CAC_Intertek_Listing_707 727 747 70PSF Singles and Pairs.pdf Quality Assurance Contract Expiration Date 12/31/2026 Installation Instructions FL8768_R6_II_Installation Instructions RD0448_Rev3.pdf FL8768_R6_II_Product Summary RD0447_Rev4.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 8768.4 |
CURRIES Model 707, 727, and 747 out-swing or in-swing doors |
CURRIES 707, 727, or 747 3’0” x 7’0” Flush, Glazed, or Louvered single doors. May use Rockwood WLV60 Louver or a FBC Approved Louver. See RD0448R3 CURRIES Installation Instructions. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: Not qualified for water infiltration;
Exit devices not allowed on in-swing doors; Qualified for HVHZ and Large Missile Impact |
Certification Agency Certificate FL8768_R6_C_CAC_Intertek_Listing_707 727 747 70PSF Singles and Pairs.pdf Quality Assurance Contract Expiration Date 12/31/2026 Installation Instructions FL8768_R6_II_Installation Instructions RD0448_Rev3.pdf FL8768_R6_II_Product Summary RD0447_Rev4.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 8768.5 |
CURRIES Model 707, 727, and 747 out-swing or in-swing doors |
CURRIES 707, 727, or 747 3’0” x 7’0” Flush door. See RD0448R3 CURRIES Installation Instructions. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +115/-115 Other: Not qualified for water infiltration; Qualified for HVHZ and Large Missile Impact |
Certification Agency Certificate FL8768_R6_C_CAC_Intertek_Listing_115PSF Singles.pdf Quality Assurance Contract Expiration Date 12/31/2026 Installation Instructions FL8768_R6_II_Installation Instructions RD0448_Rev3.pdf FL8768_R6_II_Product Summary RD0447_Rev4.pdf Verified By: Intertek Testing Services NA, Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |