|
|
| 27399.1 |
a. "Non-Impact" Fixed / Transom Window |
"Non-Impact" Transom / Fixed Window with Composite Frame is available in Rectangular, Ellipse, Radius and Segmented Head Elevations. (Insulated Glass or Triple Glazed Decorative Glass) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 27399.1 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Fasteners & connectors in areas within 3000 ft (914 m) of a saltwater coastline shall comply with FBC Sections 1711.1 or R332.1. |
Installation Instructions FL27399_R4_II_(d) Inst 27399.1.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL27399_R4_AE_(d) Eval 27399.1.pdf Created by Independent Third Party: Yes |
|
|
| 27399.2 |
b. "Impact" Fixed / Transom Window |
"Impact" Transom / Fixed Window with Composite Frame is available in Rectangular, Ellipse, Radius and Segmented Head Elevations. (Insulated Glass or Triple Glazed Decorative Glass) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 27399.2 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Fasteners & connectors in areas within 3000 ft (914 m) of a saltwater coastline shall comply with FBC Sections 1711.1 or R332.1. |
Installation Instructions FL27399_R4_II_(d) Inst 27399.2.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL27399_R4_AE_(d) Eval 27399.2.pdf Created by Independent Third Party: Yes |
|
|
| 27399.3 |
c."Impact" Fixed / Transom Window |
"Impact" Transom / Fixed Window with Composite Frame is available in Rectangular, Ellipse, Radius and Segmented Head Elevations. (Insulated Glass or Triple Glazed Decorative Glass) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 27399.3 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. Fasteners & connectors in areas within 3000 ft (914 m) of a saltwater coastline shall comply with FBC Sections 1711.1 or R332.1. |
Installation Instructions FL27399_R4_II_(d) Inst 27399.3.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL27399_R4_AE_(d) Eval 27399.3.pdf Created by Independent Third Party: Yes |