Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL8289-R4
Application Type Affirmation
Code Version 2014
Application Status Approved
 
Comments
Archived
 
Product Manufacturer GlassCraft Door Corporation
Address/Phone/Email 2002 Brittmoore Road
Houston, TX 77043-2209
(713) 690-8282
dans@glasscraft.net
 
Authorized Signature Dan Sitkowski
dans@glasscraft.net
 
Technical Representative Gene Denley
Address/Phone/Email 2002 Brittmoore Rd.
Houston, TX 77043
(800) 766-2196   Ext 240
gened@glasscraft.net
 
Quality Assurance Representative Gene Denley
Address/Phone/Email 2002 Brittmoore Rd.
Houston, TX 77043
(713) 690-8282   Ext 256
gened@glasscraft.net
 
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
 
Compliance Method Test Report
 
Testing Lab Architectural Testing, Inc. (an Intertek company) - York, PA
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Rene J.Quiroga, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL8289_R4_COI_Certificate of Independence.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E 330-022002
 
Equivalence of Product Standards
Certified By

 
 
 
Documentation from approved Evaluation or Validation Entity
 
 
Product Approval Method Method 1 Option B
 
Date Submitted 05/27/2015
Date Validated 05/27/2015
Date Pending FBC Approval
Date Approved 05/31/2015
 
Summary of Products
FL # Model, Number or Name Description
8289.1 Estancia Hardwood Door Estancia 42" x 8' or smaller in swing single door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +47.2/-51.4
 Other: Assembly not tested for air or water infiltration.
Installation Instructions
 FL8289_R4_II_69320.01-801-44-r3.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX
Test Reports
 FL8289_R4_TR_69320.01-801-44-r3.pdf
8289.2 Estancia Hardwood Doors Estancia 42" x 8' or smaller out swing single door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +47.2/-51.4
 Other: Assembly not tested for air or water infiltration.
Installation Instructions
 FL8289_R4_II_69316.01-801-44-r3.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX
Test Reports
 FL8289_R4_TR_69316.01-801-44-r3.pdf
8289.3 Portobello Hardwood Doors Portobello 42" x 8' or smaller out swing single door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +47.2/-51.4
 Other: Assembly not tested for air or water infiltration.
Installation Instructions
 FL8289_R4_II_69316.01-801-44-r3.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX
Test Reports
 FL8289_R4_TR_69316.01-801-44-r3.pdf
8289.4 Portobello Hardwood Doors Portobello 42" x 8' or smaller in swing single door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +47.2/-51.4
 Other: Assembly not tested for air or water infiltration.
Installation Instructions
 FL8289_R4_II_69320.01-801-44-r3.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX
Test Reports
 FL8289_R4_TR_69320.01-801-44-r3.pdf
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex