| 17227.1 |
CSH-TZ |
Concealed Stringer Hanger |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL17227_R5_II_ESR-4517 Jan2025.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL17227_R5_AE_ESR-4517 Jan2025.pdf |
|
|
| 17227.2 |
HDQ179IF, HDQ17112IF, HDQ1714IF, HDQ310IF, HDQ210-2IF, HDQ410IF, HDQ412IF, HDQ210-3IF, HDQ5210IF, HDQ5212IF, HDQ610IF, HDQ612IF |
Face Mount Inverted Flange Hangers |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL17227_R5_II_ESR-4517 Jan2025.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL17227_R5_AE_ESR-4517 Jan2025.pdf |
|
|
| 17227.3 |
HTC4 |
Heavy Truss Clip |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Truss clip is designed to provide lateral support to interior non bearing walls, allowing truss to move vertically (deflect) up or down. |
Installation Instructions FL17227_R5_II_ESR-4517 Jan2025.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL17227_R5_AE_ESR-4517 Jan2025.pdf |
|
|
| 17227.4 |
JDS24S |
Purlin Hangers |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL17227_R5_II_ESR-4517 Jan2025.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL17227_R5_AE_ESR-4517 Jan2025.pdf |
|
|
| 17227.5 |
JDS26S, JDS24, JDS26, JDS26-175 |
Purlin Hangers |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Max nailing required for JDS26S and JDS24 installation in HVHZ |
Installation Instructions FL17227_R5_II_ESR-4517 Jan2025.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL17227_R5_AE_ESR-4517 Jan2025.pdf |
|
|
| 17227.6 |
JL24-IF |
Inverted Flange Joist Hangers |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL17227_R5_II_ESR-4517 Jan2025.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL17227_R5_AE_ESR-4517 Jan2025.pdf |
|
|
| 17227.7 |
JL26-IF, JL28-IF, JL210-IF |
Inverted Flange Joist Hangers |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL17227_R5_II_ESR-4517 Jan2025.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL17227_R5_AE_ESR-4517 Jan2025.pdf |
|
|
| 17227.8 |
MUS26, MUS28 |
Slant Nail Joist Hanagers |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL17227_R5_II_ESR-4517 Jan2025.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL17227_R5_AE_ESR-4517 Jan2025.pdf |
|
|
| 17227.9 |
RBC |
Roof Boundary Clip |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: RBC is designed to resist lateral forces only and is not part of the uplift-resisting system. |
Installation Instructions FL17227_R5_II_ESR-4517 Jan2025.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL17227_R5_AE_ESR-4517 Jan2025.pdf |