| 17204.1 |
40MM ER SLAT BERTHA IMPACT PROTECTIVE ROLLING SYSTEM -HVHZ - Drawing 26-098 |
Extruded aluminum slats interlocked together thru knuckles and retained by tracks to provide hurricane protection |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +45/-45 Other: Large missile. A.S.D. pressure rating: +45, - 45 p.s.f. at 16’-0” span and +120,-120 p.s.f. at 6’-10” span for slat 1 wall mounted in concrete. See sheets 7 and 17 thru 19 for other spans and loads for Slats 1 and 3. |
Installation Instructions FL17204_R7_II_Drawing 26-098.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL17204_R7_AE_PE Report Drawing 26-098.pdf Created by Independent Third Party: Yes |