Product Approval Menu > Application Detail
 
FL # FL6529-R11
Application Type Revision
Code Version 2026
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Marvin
Address/Phone/Email Hwy 11 West
Warroad, MN 56763
(218) 386-1430   Ext 2143
cherylf@marvin.com
 
Authorized Signature Marisha Mollberg
marisham@marvin.com
 
Technical Representative Marisha Mollberg
Address/Phone/Email 401 State Ave N Marvin Window
WARROAD, MN 56763
(800) 346-5044
marisham@marvin.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Windows
Subcategory Horizontal Slider
 
Compliance Method Certification Mark or Listing
 
Certification Agency Window and Door Manufacturer Association
Validated By Window and Door Manufacturers Association
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
101/I.S.2/A4402011
101/I.S.2/A4402017
 
Equivalence of Product Standards
Certified By

 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 09/30/2026
Date Validated 10/05/2026
Date Pending FBC Approval
Date Approved 10/11/2026
 
Summary of Products
FL # Model, Number or Name Description
6529.1 ELGL 7242 Elevate Glider, 407-H-786
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +30/-30
 Other: Max Size: 71.5 x 41.75 inches. Product must be installed per the attached installation drawing. Glass complies with ASTM E1300.
Certification Agency Certificate
 FL6529_R11_C_CAC_ELGL 7242.pdf
Quality Assurance Contract Expiration Date
 09/13/2027
Installation Instructions
 FL6529_R11_II_00113282 Installation.pdf
 FL6529_R11_II_00113696 Installation.pdf
 FL6529_R11_II_Install 786.12 - .23 (00078915).pdf
 FL6529_R11_II_Install 786.14 - .21 (00075864).pdf
 FL6529_R11_II_Section 1711.1.2 Corrosion Statement.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 FL6529_R11_AE_EvalReport-Glider_2026.pdf
 Created by Independent Third Party: Yes
6529.2 ELGL 7260 Elevate Glider, 407-H-786
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +30/-30
 Other: Max Size: 71.5 x 59.75 inches. Product must be installed per the attached installation drawing. Glass complies with ASTM E1300.
Certification Agency Certificate
 FL6529_R11_C_CAC_ELGL 7260.pdf
Quality Assurance Contract Expiration Date
 09/13/2027
Installation Instructions
 FL6529_R11_II_00113282 Installation.pdf
 FL6529_R11_II_00113696 Installation.pdf
 FL6529_R11_II_Install 786.12 - .23 (00078915).pdf
 FL6529_R11_II_Install 786.14 - .21 (00075864).pdf
 FL6529_R11_II_Section 1711.1.2 Corrosion Statement.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 FL6529_R11_AE_EvalReport-Glider_2026.pdf
 Created by Independent Third Party: Yes
6529.3 ELGLTS 9642 Elevate Glider Triple Sash, 407-H-786
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +30/-30
 Other: Max Size: 95.4375 x 41.75 inches. Product must be installed per the attached installation drawing. Glass complies with ASTM E1300.
Certification Agency Certificate
 FL6529_R11_C_CAC_ELGLTS 9642.pdf
Quality Assurance Contract Expiration Date
 03/12/2028
Installation Instructions
 FL6529_R11_II_00113282 Installation.pdf
 FL6529_R11_II_00113696 Installation.pdf
 FL6529_R11_II_Install 786.12 - .23 (00078915).pdf
 FL6529_R11_II_Install 786.14 - .21 (00075864).pdf
 FL6529_R11_II_Section 1711.1.2 Corrosion Statement.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 FL6529_R11_AE_EvalReport-Glider_2026.pdf
 Created by Independent Third Party: Yes
6529.4 ELGLTS 9660 Elevate Glider Triple Sash, 407-H-786
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +30/-30
 Other: Max Size: 95.4375 x 59.75 inches. Product must be installed per the attached installation drawing. Glass complies with ASTM E1300.
Certification Agency Certificate
 FL6529_R11_C_CAC_ELGLTS 9660.pdf
Quality Assurance Contract Expiration Date
 03/12/2028
Installation Instructions
 FL6529_R11_II_00113282 Installation.pdf
 FL6529_R11_II_00113696 Installation.pdf
 FL6529_R11_II_Install 786.12 - .23 (00078915).pdf
 FL6529_R11_II_Install 786.14 - .21 (00075864).pdf
 FL6529_R11_II_Section 1711.1.2 Corrosion Statement.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 FL6529_R11_AE_EvalReport-Glider_2026.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex