| 6525.1 |
ELDH 4276 |
Elevate Double Hung 407-H-783 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Max Size: 41.5 x 75.75 inches. Glass complies with ASTM E1300. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026). |
Certification Agency Certificate FL6525_R16_C_CAC_783.66.pdf Quality Assurance Contract Expiration Date 03/25/2030 Installation Instructions FL6525_R16_II_52745 ELDH.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 6525.2 |
ELDH 4284 |
Elevate Double Hung 407-H-783 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max Size: 41.5 x 83.75 inches. Glass complies with ASTM E1300. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026). |
Certification Agency Certificate FL6525_R16_C_CAC_783.60.pdf Quality Assurance Contract Expiration Date 03/25/2030 Installation Instructions FL6525_R16_II_00052745 ELDH.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 6525.3 |
ELDH 5476 |
Elevate Double Hung 407-H-783 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max Size: 53.5 x 75.75 inches. Glass complies with ASTM E1300. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026). |
Certification Agency Certificate FL6525_R16_C_CAC_783.62.pdf Quality Assurance Contract Expiration Date 03/25/2030 Installation Instructions FL6525_R16_II_00052745 ELDH.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 6525.4 |
ELDH 5484 |
Elevate Double Hung 407-H-783 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: Max frame Size: 53.5 x 83.75 inches. Glass complies with ASTM E1300. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026). |
Certification Agency Certificate FL6525_R16_C_CAC_783.56.pdf Quality Assurance Contract Expiration Date 03/25/2030 Installation Instructions FL6525_R16_II_00052745 ELDH.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 6525.5 |
ELDH COTTAGE 4268 |
Elevate Double Hung Cottage 407-H-783 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max frame Size: 41.5 x 67.75 inches. Glass complies with ASTM E1300. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026). |
Certification Agency Certificate FL6525_R16_C_CAC_783.67.pdf Quality Assurance Contract Expiration Date 03/25/2030 Installation Instructions FL6525_R16_II_00052745 ELDH.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 6525.6 |
ELDH HP 5476 |
Elevate Double Hung High Performance 407-H-783 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Max Size: 53.5 x 75.75 inches. Glass complies with ASTM E1300. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026). |
Certification Agency Certificate FL6525_R16_C_CAC_783.64.pdf Quality Assurance Contract Expiration Date 03/25/2030 Installation Instructions FL6525_R16_II_00052745 ELDH.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 6525.7 |
ELDH HP 5484 |
Elevate Double Hung High Performance 407-H-783 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max frame Size: 53.5 x 83.75 inches. Glass complies with ASTM E1300. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026). |
Certification Agency Certificate FL6525_R16_C_CAC_783.58.pdf Quality Assurance Contract Expiration Date 03/25/2030 Installation Instructions FL6525_R16_II_00052745 ELDH.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 6525.8 |
ELDH IN 4284 |
Elevate Double Hung Insert 407-H-1123 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max frame Size: 42-1/16" x 84-1/2". Glass complies with ASTM E1300. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026). |
Certification Agency Certificate FL6525_R16_C_CAC_1123.02.pdf Quality Assurance Contract Expiration Date 03/25/2030 Installation Instructions FL6525_R16_II_115532 ELDHIN.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 6525.9 |
ELDH IN 5484 |
Elevate Double Hung Insert 407-H-1123 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: Max frame Size: 54-1/16 x 84-1/2 inches. Glass complies with ASTM E1300. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026). |
Certification Agency Certificate FL6525_R16_C_CAC_1123.00.pdf Quality Assurance Contract Expiration Date 03/25/2030 Installation Instructions FL6525_R16_II_115532 ELDHIN.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |