| 35290.1 |
K6744X Hurricane Louver with 0.08" or 0.125" Thick Blades |
4" Deep Horizontal Blade Louver, Extruded Aluminum, AMCA Listed, Impact & Pressure Resistant |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +200/-200 Other: Allowable Stress Design (ASD). Load & Size Ratings per Attached Table. Rated for AMCA 540 Basic Protection Missile Impact Level D (50 fps) without TAS 203 Cyclic. Rated for TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Not Rated for AMCA 550. See FL7708 for Additional Approvals. Substrates Include: Concrete (Non-Cracked), Grout Filled CMU, Steel & Wood. |
Certification Agency Certificate FL35290_R1_C_CAC_K6744X AMCA Appendix 127 on 10-20-23.pdf FL35290_R1_C_CAC_Load and Size Tables R26078.pdf Quality Assurance Contract Expiration Date 12/31/2027 Installation Instructions FL35290_R1_II_K6744X Installation Ins PE Stamped.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 35290.2 |
K6746X Hurricane Louver with 0.08" Thick Blades |
6" Deep Horizontal Blade Louver, Extruded Aluminum, AMCA Listed, Impact & Pressure Resistant |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +200/-200 Other: Allowable Stress Design (ASD). Load & Size Ratings per Attached Table. Rated for AMCA 540 Basic Protection Missile Impact Level D (50 fps) without TAS 203 Cyclic. Rated for TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Not Rated for AMCA 550. See FL7708 for Additional Approvals. Substrates Include: Concrete (Non-Cracked), Grout Filled CMU, Steel & Wood. |
Certification Agency Certificate FL35290_R1_C_CAC_K6746X (08 Blade) AMCA Appendix 133 on 10-20-23.pdf FL35290_R1_C_CAC_Load and Size Tables R26078.pdf Quality Assurance Contract Expiration Date 12/31/2027 Installation Instructions FL35290_R1_II_K6746X Installation Ins PE Stamped.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 35290.3 |
K6746X Hurricane Louver with 0.125" Thick Blades |
6" Deep Horizontal Blade Louver, Extruded Aluminum, AMCA Listed, Impact & Pressure Resistant |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +200/-200 Other: Allowable Stress Design (ASD). Load & Size Ratings per Attached Table. Rated for AMCA 540 Enhanced Protection Missile Impact Level E (80 fps) without TAS 203 Cyclic. Rated for TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Not Rated for AMCA 550. See FL7708 for Additional Approvals. Substrates Include: Concrete (Non-Cracked), Grout Filled CMU, Steel & Wood. |
Certification Agency Certificate FL35290_R1_C_CAC_K6746X (125 Blade) AMCA Appendix 132 on 10-20-23.pdf FL35290_R1_C_CAC_Load and Size Tables R26078.pdf Quality Assurance Contract Expiration Date 12/31/2027 Installation Instructions FL35290_R1_II_K6746X Installation Ins PE Stamped.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 35290.4 |
SCH501X Hurricane Louver |
5" Deep Horizontal Blade Louver, Extruded Aluminum, AMCA Listed, Impact & Pressure Resistant |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +200/-200 Other: Allowable Stress Design (ASD). Load & Size Ratings per Attached Table. Rated for AMCA 540 Enhanced Protection Missile Impact Level E (80 fps) without TAS 203 Cyclic. Rated for TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Not Rated for AMCA 550. See FL7708 for Additional Approvals. Substrates Include: Concrete (Non-Cracked), Grout Filled CMU, Steel & Wood. |
Certification Agency Certificate FL35290_R1_C_CAC_Load and Size Tables R26078.pdf FL35290_R1_C_CAC_SCH501X AMCA Appendix 140 on 10-20-23.pdf Quality Assurance Contract Expiration Date 12/31/2027 Installation Instructions FL35290_R1_II_SCH501X Installation Ins PE Stamped.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |