| 35289.1 |
EHH-501X Hurricane Louver |
5" Deep Horizontal Blade Louver, Extruded Aluminum, AMCA Listed, Impact & Pressure Resistant |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +200/-200 Other: Allowable Stress Design (ASD). Load & Size Ratings per Attached Table. Rated for AMCA 540 Enhanced Protection Missile Impact Level E (80 fps) without TAS 203 Cyclic. Rated for TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Not Rated for AMCA 550. See FL6876 for Additional Approvals. Substrates Include: Concrete (Non-Cracked), Grout Filled CMU, Steel & Wood. |
Certification Agency Certificate FL35289_R1_C_CAC_EHH-501X AMCA Appendix 412 on 10-20-23.pdf FL35289_R1_C_CAC_Load and Size Tables R25119.pdf Quality Assurance Contract Expiration Date 12/31/2027 Installation Instructions FL35289_R1_II_EHH-501X Installation PE Stamped.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 35289.2 |
ESD-435X Hurricane Louver with 0.08" or 0.125" Thick Blades |
4" Deep Horizontal Blade Louver, Extruded Aluminum, AMCA Listed, Impact & Pressure Resistant |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +200/-200 Other: Allowable Stress Design (ASD). Load & Size Ratings per Attached Table. Rated for AMCA 540 Basic Protection Missile Impact Level D (50 fps) without TAS 203 Cyclic. Rated for TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Not Rated for AMCA 550. See FL6876 for Additional Approvals. Substrates Include: Concrete (Non-Cracked), Grout Filled CMU, Steel & Wood. |
Certification Agency Certificate FL35289_R1_C_CAC_ESD-435X AMCA Appendix 419 on 10-20-23.pdf FL35289_R1_C_CAC_Load and Size Tables R25119.pdf Quality Assurance Contract Expiration Date 12/31/2027 Installation Instructions FL35289_R1_II_ESD-435X Installation Ins PE Stamped.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 35289.3 |
ESD-635X Hurricane Louver with 0.08" Thick Blades |
6" Deep Horizontal Blade Louver, Extruded Aluminum, AMCA Listed, Impact & Pressure Resistant |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +200/-200 Other: Allowable Stress Design (ASD). Load & Size Ratings per Attached Table. Rated for AMCA 540 Basic Protection Missile Impact Level D (50 fps) without TAS 203 Cyclic. Rated for TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Not Rated for AMCA 550. See FL6876 for Additional Approvals. Substrates Include: Concrete (Non-Cracked), Grout Filled CMU, Steel & Wood. |
Certification Agency Certificate FL35289_R1_C_CAC_ESD-635X (08 Blade) AMCA Appendix 424 on 10-20-23.pdf FL35289_R1_C_CAC_Load and Size Tables R25119.pdf Quality Assurance Contract Expiration Date 12/31/2027 Installation Instructions FL35289_R1_II_ESD-635X Installation Ins PE Stamped.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 35289.4 |
ESD-635X Hurricane Louver with 0.125" Thick Blades |
6" Deep Horizontal Blade Louver, Extruded Aluminum, AMCA Listed, Impact & Pressure Resistant |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +200/-200 Other: Allowable Stress Design (ASD). Load & Size Ratings per Attached Table. Rated for AMCA 540 Enhanced Protection Missile Impact Level E (80 fps) without TAS 203 Cyclic. Rated for TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Not Rated for AMCA 550. See FL6876 for Additional Approvals. Substrates Include: Concrete (Non-Cracked), Grout Filled CMU, Steel & Wood. |
Certification Agency Certificate FL35289_R1_C_CAC_ESD-635X (125 Blade) AMCA Appendix 425 on 10-20-23.pdf FL35289_R1_C_CAC_Load and Size Tables R25119.pdf Quality Assurance Contract Expiration Date 12/31/2027 Installation Instructions FL35289_R1_II_ESD-635X Installation Ins PE Stamped.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |