| 15504.1 |
01 W3-09 DSIE-1A171: 2050, 4050, 2051, 4051, 2053, 4053, 62, 62G, 62LG, 6130, 65, 65G, 6131, 64, 64G, 6133, 135, SDP38, 136, SFL38, 134, SRP38 |
Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 29 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W3 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC). |
Installation Instructions FL15504_R13_II_101655-Rev15.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL15504_R13_AE_CC_240229-A.0.pdf Created by Independent Third Party: No |
|
|
| 15504.2 |
02 W3-09 PAN-2F151: 84A, 94, 96, 96V, 73, 75, 1500, 190, 75L, 76, 76V, 4RST, 4F, 4RSF, 6RST, 6RSF, 2RST, 48, 48B, 42, 42B, 55, 55S, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) Single-Car (up to 9’0” wide) WINDCODE® W3 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL15504_R13_II_104677-Rev02_s.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15504_R13_AE_CC_240229-A.0.pdf Created by Independent Third Party: No |
|
|
| 15504.3 |
03 W5-16 PAN-2F153/6: 84A, 94, 96, 96V, 73, 75, 1500, 190, 75L, 76, 76V, 4RST, 4F, 4RSF, 6RST, 6RSF, 2RST, 48, 48B, 42, 42B, 55, 55S, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) Double-Car (9’2” to 16’0” wide) WINDCODE® W5 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +28 PSF/-30.5 PSF Other: Solid doors (no glazing) or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL15504_R13_II_104698-A-Rev02_s.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL15504_R13_AE_CC_240229-A.0.pdf Created by Independent Third Party: No |
|
|
| 15504.4 |
04 W5-16 PAN-2F153/6: 84A, 94, 96, 96V, 73, 75, 1500, 190, 75L, 76, 76V, 4RST, 4F, 4RSF, 6RST, 6RSF, 2RST, 48, 48B, 42, 42B, 55, 55S, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) Double-Car (9’2” to 16’0” wide) WINDCODE® W5 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +28 PSF/-30.5 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. |
Installation Instructions FL15504_R13_II_104698-B-Rev02_s.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15504_R13_AE_CC_240229-A.0.pdf Created by Independent Third Party: No |
|
|
| 15504.5 |
05 W6-10 W-1G899: Custom Reserve Collection CRDnnn, CR800, MR800, CH900 |
Custom Wood Single-Car (up to 10’0” wide) WINDCODE® W6 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +36.5 PSF/-40.5 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC). |
Installation Instructions FL15504_R13_II_104700-Rev01.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL15504_R13_AE_CC_240229-A.0.pdf Created by Independent Third Party: No |
|
|
| 15504.6 |
06 W7-09 W-1G899: Custom Reserve Collection CRDnnn, CR800, MR800, CH900 |
Custom Wood Single-Car (up to 9’0” wide) WINDCODE® W7 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +45 PSF/-50 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL15504_R13_II_104699-Rev01.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL15504_R13_AE_CC_240229-A.0.pdf Created by Independent Third Party: No |
|
|
| 15504.7 |
07 W4-09 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-28 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL15504_R13_II_104947-Rev02.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL15504_R13_AE_CC_240229-A.0.pdf Created by Independent Third Party: No |
|
|
| 15504.8 |
08 W4-16 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9’2” to 16’0” wide) WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +24 PSF/-26.5 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL15504_R13_II_104704-Rev02.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL15504_R13_AE_CC_240229-A.0.pdf Created by Independent Third Party: No |
|
|
| 15504.9 |
09 W4-18 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) 16'2" to 18'0" wide WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +24 PSF/-26 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL15504_R13_II_104887-Rev02.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL15504_R13_AE_CC_240229-A.0.pdf Created by Independent Third Party: No |
|
|
| 15504.10 |
10 W5-09 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W5 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +33 PSF/-37 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions.
|
Installation Instructions FL15504_R13_II_104866-B-Rev04.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL15504_R13_AE_CC_240229-A.0.pdf Created by Independent Third Party: No |
|
|
| 15504.11 |
11 W5-16 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9’2” to 16’0” wide) WINDCODE® W5 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +32 PSF/-32 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions.
|
Installation Instructions FL15504_R13_II_104723-B-Rev05_s.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL15504_R13_AE_CC_240229-A.0.pdf Created by Independent Third Party: No |
|
|
| 15504.12 |
12 W6-09 DSIE-1F171: 4400, 4401, 4300, 4301, 4310, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 |
Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9'0" wide) WINDCODE® W6 Garage Door with Optional Impact-Resistant Lites
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +38 PSF/-44 PSF Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL15504_R13_II_101526-A-Rev22.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL15504_R13_AE_CC_240229-A.0.pdf Created by Independent Third Party: No |
|
|
| 15504.13 |
13 W6-09 DSIE-1F171: 4400, 4401, 4300, 4301, 4310, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 |
Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9'0" wide) WINDCODE® W6 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +38 PSF/-44 PSF Other: Doors with standard glazing meet the wind load requirements of the building code but DO NOT meet the impact resistant requirement for windborne debris regions.
|
Installation Instructions FL15504_R13_II_101526-B-Rev22.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL15504_R13_AE_CC_240229-A.0.pdf Created by Independent Third Party: No |
|
|
| 15504.14 |
14 W8-09 PAN-2F443: GD4S, GR4S, ED4S, AR4S |
Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) Single-Car (up to 9’0” wide) WINDCODE® W8 Garage Door with Optional Impact-Resistant Lites
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50 PSF/-58 PSF Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors (no glazing) or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL15504_R13_II_104121-Rev08.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15504_R13_AE_CCER_240229-A-02.pdf Created by Independent Third Party: No |
|
|
| 15504.15 |
15 W5-09 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W5 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +33 PSF/-37 PSF Other: Solid doors (no glazing) or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL15504_R13_II_104866-A-Rev04.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL15504_R13_AE_CC_240229-A.0.pdf Created by Independent Third Party: No |
|
|
| 15504.16 |
16 W5-16 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9’2” to 16’0” wide) WINDCODE® W5 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +32 PSF/-32 PSF Other: Solid doors (no glazing) or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL15504_R13_II_104723-A-Rev05_s.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL15504_R13_AE_CC_240229-A.0.pdf Created by Independent Third Party: No |
|
|
| 15504.17 |
17 W4-09 PAN-2F151: 73, 1500, 75, 190, 84A, 94, 4F, 94V, 76, 42, 48, 55, 42B, 48B, 55S, 4RST, 6RST, 4RSF, 6RSF, 2RST, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) Single-Car (up to 9’0” wide) WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +25 PSF/-32 PSF Other: Solid doors (no glazing) or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL15504_R13_II_300159-A-Rev19_s.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15504_R13_AE_CC_240229-A.0.pdf Created by Independent Third Party: No |
|
|
| 15504.18 |
18 W4-09 PAN-2F151: 73, 1500, 75, 190, 84A, 94, 4F, 94V, 76, 42, 48, 55, 42B, 48B, 55S, 4RST, 6RST, 4RSF, 6RSF, 2RST, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) Single-Car (up to 9’0” wide) WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-32 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions.
|
Installation Instructions FL15504_R13_II_300159-B-Rev19_s.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15504_R13_AE_CC_240229-A.0.pdf Created by Independent Third Party: No |
|
|
| 15504.19 |
19 W4-09 DSIEO-1M749 // DSIUO-1M479: EPS // URETHANE Coachman / Settlers / Affinity |
Double Skin Insulated (exterior skin 27 ga. min.; interior skin 27ga. min.) with Overlay Single-Car (up to 9’0” wide) WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +28 PSF/-29 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL15504_R13_II_104471-Rev02_s.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL15504_R13_AE_CC_240229-A.0.pdf Created by Independent Third Party: No |
|
|
| 15504.20 |
20 W4-16 DSIEO-1M749 // DSIUO-1M479: EPS // URETHANE Coachman / Settlers / Affinity |
Double Skin Insulated (exterior skin 27 ga. min.; interior skin 27ga. min.) with Overlay Double-Car (9’2” to 16’0” wide) WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25.5 PSF/-25.5 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL15504_R13_II_104472-Rev02_s.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL15504_R13_AE_CC_240229-A.0.pdf Created by Independent Third Party: No |