FL # FL15504-R13
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Clopay Building Products Company
Address/Phone/Email 8585 Duke Blvd.
Mason, OH 45040
(513) 770-4641
jwheeler@clopay.com
 
Authorized Signature Jim Wheeler
jwheeler@clopay.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Exterior Doors
Subcategory Sectional Exterior Door Assemblies
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Jim Wheeler
Florida License PE-91932
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2030
Validated By Gary Pfuehler
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL15504_R13_COI_Certification_of_Independence_of_Validation_Entity-Gary_Pfuehler.pdf
FL15504_R13_COI_Statement_of_Independence_of_Evaluation_Entity_JDW_240626.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ANSI/DASMA 1082005
ANSI/DASMA 1152005
ASTM E18862005
ASTM E19962006
ASTM E3302002
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL15504_R13_Equiv_Statement_of_Equivalency_E1886.pdf
FL15504_R13_Equiv_Statement_of_Equivalency_E330.pdf
 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 10/17/2025
Date Validated 10/20/2025
Date Pending FBC Approval 10/22/2025
Date Approved 12/09/2025
 
Summary of Products
          Page 1 / 2    
FL # Model, Number or Name Description
15504.1 01 W3-09 DSIE-1A171: 2050, 4050, 2051, 4051, 2053, 4053, 62, 62G, 62LG, 6130, 65, 65G, 6131, 64, 64G, 6133, 135, SDP38, 136, SFL38, 134, SRP38 Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 29 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W3 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +20 PSF/-21 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL15504_R13_II_101655-Rev15.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL15504_R13_AE_CC_240229-A.0.pdf
 Created by Independent Third Party: No
15504.2 02 W3-09 PAN-2F151: 84A, 94, 96, 96V, 73, 75, 1500, 190, 75L, 76, 76V, 4RST, 4F, 4RSF, 6RST, 6RSF, 2RST, 48, 48B, 42, 42B, 55, 55S, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV Steel Pan (min. 25 ga.) Single-Car (up to 9’0” wide) WINDCODE® W3 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +20 PSF/-21 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL15504_R13_II_104677-Rev02_s.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL15504_R13_AE_CC_240229-A.0.pdf
 Created by Independent Third Party: No
15504.3 03 W5-16 PAN-2F153/6: 84A, 94, 96, 96V, 73, 75, 1500, 190, 75L, 76, 76V, 4RST, 4F, 4RSF, 6RST, 6RSF, 2RST, 48, 48B, 42, 42B, 55, 55S, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV Steel Pan (min. 25 ga.) Double-Car (9’2” to 16’0” wide) WINDCODE® W5 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +28 PSF/-30.5 PSF
 Other: Solid doors (no glazing) or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
Installation Instructions
 FL15504_R13_II_104698-A-Rev02_s.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL15504_R13_AE_CC_240229-A.0.pdf
 Created by Independent Third Party: No
15504.4 04 W5-16 PAN-2F153/6: 84A, 94, 96, 96V, 73, 75, 1500, 190, 75L, 76, 76V, 4RST, 4F, 4RSF, 6RST, 6RSF, 2RST, 48, 48B, 42, 42B, 55, 55S, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV Steel Pan (min. 25 ga.) Double-Car (9’2” to 16’0” wide) WINDCODE® W5 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +28 PSF/-30.5 PSF
 Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions.
Installation Instructions
 FL15504_R13_II_104698-B-Rev02_s.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL15504_R13_AE_CC_240229-A.0.pdf
 Created by Independent Third Party: No
15504.5 05 W6-10 W-1G899: Custom Reserve Collection CRDnnn, CR800, MR800, CH900 Custom Wood Single-Car (up to 10’0” wide) WINDCODE® W6 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +36.5 PSF/-40.5 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL15504_R13_II_104700-Rev01.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL15504_R13_AE_CC_240229-A.0.pdf
 Created by Independent Third Party: No
15504.6 06 W7-09 W-1G899: Custom Reserve Collection CRDnnn, CR800, MR800, CH900 Custom Wood Single-Car (up to 9’0” wide) WINDCODE® W7 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +45 PSF/-50 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL15504_R13_II_104699-Rev01.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL15504_R13_AE_CC_240229-A.0.pdf
 Created by Independent Third Party: No
15504.7 07 W4-09 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W4 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +25 PSF/-28 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL15504_R13_II_104947-Rev02.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL15504_R13_AE_CC_240229-A.0.pdf
 Created by Independent Third Party: No
15504.8 08 W4-16 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9’2” to 16’0” wide) WINDCODE® W4 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +24 PSF/-26.5 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL15504_R13_II_104704-Rev02.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL15504_R13_AE_CC_240229-A.0.pdf
 Created by Independent Third Party: No
15504.9 09 W4-18 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) 16'2" to 18'0" wide WINDCODE® W4 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +24 PSF/-26 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL15504_R13_II_104887-Rev02.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL15504_R13_AE_CC_240229-A.0.pdf
 Created by Independent Third Party: No
15504.10 10 W5-09 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W5 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +33 PSF/-37 PSF
 Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions.
Installation Instructions
 FL15504_R13_II_104866-B-Rev04.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL15504_R13_AE_CC_240229-A.0.pdf
 Created by Independent Third Party: No
15504.11 11 W5-16 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9’2” to 16’0” wide) WINDCODE® W5 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +32 PSF/-32 PSF
 Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions.
Installation Instructions
 FL15504_R13_II_104723-B-Rev05_s.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL15504_R13_AE_CC_240229-A.0.pdf
 Created by Independent Third Party: No
15504.12 12 W6-09 DSIE-1F171: 4400, 4401, 4300, 4301, 4310, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9'0" wide) WINDCODE® W6 Garage Door with Optional Impact-Resistant Lites
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +38 PSF/-44 PSF
 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
Installation Instructions
 FL15504_R13_II_101526-A-Rev22.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL15504_R13_AE_CC_240229-A.0.pdf
 Created by Independent Third Party: No
15504.13 13 W6-09 DSIE-1F171: 4400, 4401, 4300, 4301, 4310, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9'0" wide) WINDCODE® W6 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +38 PSF/-44 PSF
 Other: Doors with standard glazing meet the wind load requirements of the building code but DO NOT meet the impact resistant requirement for windborne debris regions.
Installation Instructions
 FL15504_R13_II_101526-B-Rev22.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL15504_R13_AE_CC_240229-A.0.pdf
 Created by Independent Third Party: No
15504.14 14 W8-09 PAN-2F443: GD4S, GR4S, ED4S, AR4S Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) Single-Car (up to 9’0” wide) WINDCODE® W8 Garage Door with Optional Impact-Resistant Lites
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50 PSF/-58 PSF
 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors (no glazing) or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
Installation Instructions
 FL15504_R13_II_104121-Rev08.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL15504_R13_AE_CCER_240229-A-02.pdf
 Created by Independent Third Party: No
15504.15 15 W5-09 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W5 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +33 PSF/-37 PSF
 Other: Solid doors (no glazing) or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
Installation Instructions
 FL15504_R13_II_104866-A-Rev04.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL15504_R13_AE_CC_240229-A.0.pdf
 Created by Independent Third Party: No
15504.16 16 W5-16 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9’2” to 16’0” wide) WINDCODE® W5 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +32 PSF/-32 PSF
 Other: Solid doors (no glazing) or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
Installation Instructions
 FL15504_R13_II_104723-A-Rev05_s.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL15504_R13_AE_CC_240229-A.0.pdf
 Created by Independent Third Party: No
15504.17 17 W4-09 PAN-2F151: 73, 1500, 75, 190, 84A, 94, 4F, 94V, 76, 42, 48, 55, 42B, 48B, 55S, 4RST, 6RST, 4RSF, 6RSF, 2RST, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV Steel Pan (min. 25 ga.) Single-Car (up to 9’0” wide) WINDCODE® W4 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +25 PSF/-32 PSF
 Other: Solid doors (no glazing) or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
Installation Instructions
 FL15504_R13_II_300159-A-Rev19_s.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL15504_R13_AE_CC_240229-A.0.pdf
 Created by Independent Third Party: No
15504.18 18 W4-09 PAN-2F151: 73, 1500, 75, 190, 84A, 94, 4F, 94V, 76, 42, 48, 55, 42B, 48B, 55S, 4RST, 6RST, 4RSF, 6RSF, 2RST, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV Steel Pan (min. 25 ga.) Single-Car (up to 9’0” wide) WINDCODE® W4 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +25 PSF/-32 PSF
 Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions.
Installation Instructions
 FL15504_R13_II_300159-B-Rev19_s.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL15504_R13_AE_CC_240229-A.0.pdf
 Created by Independent Third Party: No
15504.19 19 W4-09 DSIEO-1M749 // DSIUO-1M479: EPS // URETHANE Coachman / Settlers / Affinity Double Skin Insulated (exterior skin 27 ga. min.; interior skin 27ga. min.) with Overlay Single-Car (up to 9’0” wide) WINDCODE® W4 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +28 PSF/-29 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL15504_R13_II_104471-Rev02_s.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL15504_R13_AE_CC_240229-A.0.pdf
 Created by Independent Third Party: No
15504.20 20 W4-16 DSIEO-1M749 // DSIUO-1M479: EPS // URETHANE Coachman / Settlers / Affinity Double Skin Insulated (exterior skin 27 ga. min.; interior skin 27ga. min.) with Overlay Double-Car (9’2” to 16’0” wide) WINDCODE® W4 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +25.5 PSF/-25.5 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL15504_R13_II_104472-Rev02_s.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL15504_R13_AE_CC_240229-A.0.pdf
 Created by Independent Third Party: No
          Page 1 / 2    
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex